Integrated megavoltage portal imaging with a 1.5 T MRI linac

被引:31
|
作者
Raaymakers, B. W. [1 ]
de Boer, J. C. J. [1 ]
Knox, C. [1 ]
Crijns, S. P. M. [1 ]
Smit, K. [1 ]
Stam, M. K. [1 ]
van den Bosch, M. R. [1 ]
Kok, J. G. M. [1 ]
Lagendijk, J. J. W. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, NL-3584 CX Utrecht, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 19期
关键词
RADIOTHERAPY; DEVICE; VERIFICATION; DISTORTIONS; QUALITY; CANCER;
D O I
10.1088/0031-9155/56/19/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this note, the feasibility of complementing our hybrid 1.5 T MRI linac (MRL) with a megavoltage (MV) portal imager is investigated. A standard aSi MV detector panel is added to the system and both qualitative and quantitative performances are determined. Simultaneous MR imaging and transmission imaging can be performed without mutual interference. The MV image quality is compromised by beam transmission and longer isocentre distance; still, the field edges and bony anatomy can be detected at very low dose levels of 0.4 cGy. MV imaging integrated with the MRL provides an independent and well-established position verification tool, a field edge check and a calibration for alignment of the coordinate systems of the MRI and the accelerator. The portal imager can also be a valuable means for benchmarking MRI-guided position verification protocols on a patient-specific basis in the introductory phase.
引用
收藏
页码:N207 / N214
页数:8
相关论文
共 50 条
  • [41] INTEGRATED 1.5 T MRI AND ACCELERATOR: PROOF OF CONCEPT FOR REAL-TIME MRI GUIDED RADIOTHERAPY
    Raaymakers, B.
    Lagendijk, J.
    Overweg, J.
    Kok, J.
    Raaijmakers, A.
    Kerkhof, E.
    van der Put, R.
    Meijsing, I.
    Crijns, S.
    Benedosso, F.
    van Vulpen, M.
    de Graaff, N.
    Allen, J.
    Brown, K.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S33 - S33
  • [42] Quantitative Imaging Techniques on a 1.5 T MR-Linac: Acquisition of Diffusion Weighted Imaging and Quantitative T2 for the Prostate.
    Morris, S. R.
    Maier, C.
    Dresner, A.
    Wang, H.
    Chen, T.
    Bloch, T.
    Lattanzi, R.
    Byun, D.
    Zelefsky, M. J.
    MEDICAL PHYSICS, 2024, 51 (10) : 7911 - 7912
  • [43] Comparison of portal imaging and megavoltage verification films for conformal pelvic irradiation
    Thompson, V
    Bidmead, M
    Mubata, C
    BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (828): : 1191 - 1195
  • [44] Value of 3.0 T MR imaging in refractory partial epilepsy and negative 1.5 T MRI
    Nguyen, Dang Khoa
    Rochette, Emilie
    Leroux, Jean-Maxime
    Beaudoin, Gilles
    Cossette, Patrick
    Lassonde, Maryse
    Guilbert, Francois
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2010, 19 (08): : 475 - 478
  • [45] Anatomical MR imaging of long bones: Comparative performance of MRI at 1.5 T and 3 T
    Rathnayaka, Kanchana
    Momot, Konstantin I.
    Coulthard, Alan
    Volp, Andrew
    Sahama, Tony
    Schuetz, Michael A.
    Schmutz, Beat
    BIOMEDICAL SPECTROSCOPY AND IMAGING, 2013, 2 (01) : 21 - 35
  • [46] RF EXCITER CONTROL SYSTEM FOR HEAD IMAGING IN 1.5T MRI
    Nerurkar, Krutika
    Mane, Pranita
    Bhuiya, Tapas K.
    Padwal, Vishal
    Harsh, Rajesh
    2021 IEEE MTT-S INTERNATIONAL MICROWAVE AND RF CONFERENCE (IMARC), 2021,
  • [47] Beam quality specifiers for an integrated MRI-linac
    O'Brien, D. J.
    Roberts, D. A.
    Towe, S.
    Ibbott, G.
    Sawakuchi, G. O.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S376 - S377
  • [48] Analysis of treatment times and workflow at a 1.5 T MR Linac
    Stolte, A.
    Boldt, J.
    Marks, C.
    Gani, C.
    Nachbar, M.
    De-Colle, C.
    Weidner, N.
    Mueller, A.
    Thorwarth, D.
    Zips, D.
    Boeke, S.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S274 - S274
  • [49] Patient Perspective for Treatment on a 1.5T MR Linac
    Ehlers, J.
    Gani, C.
    Marks, C.
    Stolte, A.
    Thorwarth, D.
    Weidner, N.
    Mueller, A. -C.
    Moennich, D.
    Nachbar, M.
    Dohm, O.
    Zips, D.
    Boeke, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S199 - S199
  • [50] Performance Characterization of a Clinical 1.5 T MR-Linac
    Keller, B.
    Kim, A.
    Iakovenko, V.
    Ruschin, M.
    McCann, C.
    Beachey, D.
    Chugh, B.
    Elzibak, A.
    Sahgal, A.
    Sarfehnia, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E827 - E827