DYNAMIC PIXEL BINNING ALLOWS SPATIAL AND ANGULAR RESOLUTION TRADEOFFS TO IMPROVE IMAGE QUALITY IN X-RAY C-ARM CT

被引:0
|
作者
Steg, Alexander [1 ]
Reichenbach, Marc [1 ]
Soell, Christopher [1 ]
Shi, Lan [1 ]
Maier, Andreas [1 ]
Riess, Christian [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuremberg, Dept Comp Sci, Dept Elect Engn, Erlangen, Germany
来源
2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI) | 2016年
关键词
Pixel Binning; X-ray detector; C-arm reconstruction; Dynamic Pixel Binning; X-ray C-arm CT;
D O I
10.1109/ISBI.2016.7493334
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
When designing an acquisition protocol for a C-arm CT, a tradeoff has to be made between scan time and the amount of acquired data. Increased scan time allows data acquisition with higher spatial and angular resolution. Fixed scan time implies a reduction of either spatial and angular resolution, which may either lead to oversmoothing or to artifacts from angular undersampling. In this work, we investigate smart sensors for pushing the boundary for this bottleneck considerably further. Detector pixels are enhanced by processing units that are able to perform a limited amount of local operations. This allows an online, dynamical adaptation of the pixel binning, depending on whether a local neighborhood is smooth or not. We demonstrate on phantom data that this approach allows to save about 7 5% of the data, obtaining a reconstruction quality comparable to 1 x 1 binning at a data rate comparable to 2 x 2 pixel binning.
引用
收藏
页码:577 / 580
页数:4
相关论文
共 39 条
  • [21] Inverse-Geometry CT with a Rotating C-Arm: Implementation On the Scanning Beam Digital X-Ray System
    Slagowski, J.
    Speidel, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3033 - 3033
  • [22] Image Correlation Between Digitally Reconstructed Radiographs, C-arm Fluoroscopic Radiographs, and X-ray: A Phantom Study
    Wangler, Sebastian
    Hofmann, Janic
    Moser, Helen L.
    Kuenzler, Michael
    Egli, Rainer J.
    Schaer, Michael
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [23] VDVM: An automatic vertebrae detection and vertebral segment matching framework for C-arm X-ray image identification
    Zhang, Ruyi
    Hu, Yiwei
    Zhang, Kai
    Lan, Guanhua
    Peng, Liang
    Zhu, Yabin
    Qian, Wei
    Yao, Yudong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (05) : 935 - 949
  • [24] Spatial resolution effect in myocardial fatty acid metabolic image in fluorescent x-ray CT
    Takeda, T.
    Wu, J.
    Thet-Thet-Lwin
    Sunaguchi, N.
    Yuasa, T.
    Dilmanian, F. A.
    Minami, M.
    Akatsuka, T.
    ADVANCES IN HEART DISEASE, 2006, : 197 - +
  • [25] Change your Angle of View Sinusoidal C-Arm Movement in Cranial Flat-panel CT to Improve Image Quality
    Luecking, Hannes
    Hoelter, Philip
    Lang, Stefan
    Schmidt, Manuel
    Eisenhut, Felix
    Doerfler, Arnd
    CLINICAL NEURORADIOLOGY, 2022, 32 (04) : 1109 - 1115
  • [26] High-quality 3-D coronary artery imaging on an interventional C-arm x-ray system
    Hansis, Eberhard
    Carroll, John D.
    Schaefer, Dirk
    Doessel, Olaf
    Grass, Michael
    MEDICAL PHYSICS, 2010, 37 (04) : 1601 - 1609
  • [27] X-ray Radiation Effect of Image Intensfier (C-Arm) on Adipose Tissue-Mesenchymal Stem Cell Viability and Osteogenic Differentiation
    Rahyussalim, Ahmad J.
    Pawitan, Jeanne A.
    Maska, Hendra
    Kurniawati, Tri
    ADVANCED SCIENCE LETTERS, 2017, 23 (07) : 6970 - 6974
  • [28] Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography
    Werncke, Thomas
    Sonnow, Lena
    Meyer, Bernhard C.
    Luepke, Matthias
    Hinrichs, Jan
    Wacker, Frank K.
    von Falck, Christian
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 89 : 191 - 199
  • [29] Improving 3D image quality of x-ray C-arm imaging systems by using properly designed pose determination systems for calibrating the projection geometry
    Strobel, N
    Heigl, B
    Brunner, T
    Schütz, O
    Mitschke, M
    Wiesent, K
    Mertelmeier, T
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 943 - 954
  • [30] Effects of defect pixel correction algorithms for x-ray detectors on image quality in planar projection and volumetric CT data sets
    Kuttig, Jan
    Steiding, Christian
    Hupfer, Martin
    Karolczak, Marek
    Kolditz, Daniel
    MEASUREMENT SCIENCE and TECHNOLOGY, 2015, 26 (09)