Optical Coherence Tomography Accurately Measures Corneal Power Change from Laser Refractive Surgery

被引:30
|
作者
McNabb, Ryan P. [1 ,2 ]
Farsiu, Sina [1 ,2 ]
Stinnett, Sandra S. [2 ,3 ]
Izatt, Joseph A. [1 ,2 ]
Kuo, Anthony N. [2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] Duke Univ, Dept Ophthalmol, Durham, NC USA
[3] Duke Univ, Dept Biostat & Informat, Durham, NC USA
基金
美国国家卫生研究院;
关键词
INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; MYOPIC PHOTOREFRACTIVE KERATECTOMY; REQUIRING CATARACT-SURGERY; ANTERIOR SEGMENT; VOLUMETRIC SDOCT; BIOMETRY; EYES; FORMULA; VIVO;
D O I
10.1016/j.ophtha.2014.10.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the ability of motion-corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to LASIK. Design: Evaluation of a diagnostic test or technology in a cohort. Subjects: A total of 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. A total of 39 eyes from 22 subjects were measured postoperatively and completed the study. Methods: Consecutive patients undergoing LASIK at the Duke Eye Center who consented to participate were imaged with Placido-ring topography, Scheimpflug photography, and OCT on the day of their surgery. Patients were then reimaged with the same imaging systems at the postoperative month 3 visit. Change in preoperative to postoperative corneal refractive power as measured by each of the imaging modalities was compared with the preoperative to postoperative change in manifest refraction (MRx) using the t test with generalized estimating equations. Main Outcome Measures: Corneal refractive power change due to LASIK as measured by Placido-ring topography, Scheimpflug photography, and OCT compared with the MRx change vertexed to the corneal plane. The change in MRx should correspond to the change in the corneal refractive power from LASIK and was considered the reference measurement. Results: In 22 individuals (39 eyes) returning after LASIK, we found no significant difference between the clinically measured pre- to post-LASIK change in MRx and both Scheimpflug photography (P = 0.714) and OCT (P = 0.216). In contrast, keratometry values from Placido-ring topography were found to be significantly different from the measured refractive change (P < 0.001). In addition, of the 3 imaging modalities, OCT recorded the smallest mean absolute difference from the reference measurement with the least amount of variability. Conclusions: Motion-corrected OCT more accurately measures the change in corneal refractive power due to laser refractive surgery than other currently available clinical devices. By offering accurate corneal refractive power measurements in normal and surgically modified subjects, OCT offers a compelling alternative to current clinical devices for determining corneal refractive power. (C) 2015 by the American Academy of Ophthalmology.
引用
收藏
页码:677 / 686
页数:10
相关论文
共 50 条
  • [41] The evolution of corneal and refractive surgery with the femtosecond laser
    Aristeidou, Antonis
    Taniguchi, Elise V.
    Tsatsos, Michael
    Muller, Rodrigo
    McAlinden, Colm
    Pineda, Roberto
    Paschalis, Eleftherios I.
    EYE AND VISION, 2015, 2
  • [42] Modeling the biomechanics of laser corneal refractive surgery
    Montanino, Andrea
    van Overbeeke, Sanne
    Pandolfi, Anna
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 145
  • [43] Applications of the femtosecond laser in corneal refractive surgery
    Kim, Peter
    Sutton, Gerard L.
    Rootman, David S.
    CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (04) : 238 - 244
  • [44] The evolution of corneal and refractive surgery with the femtosecond laser
    Antonis Aristeidou
    Elise V. Taniguchi
    Michael Tsatsos
    Rodrigo Muller
    Colm McAlinden
    Roberto Pineda
    Eleftherios I. Paschalis
    Eye and Vision, 2
  • [45] Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery
    Rahlves, M.
    Diaz, J. Diaz
    Thommes, J.
    Majdani, O.
    Roth, B.
    Ortmaier, T.
    Reithmeier, E.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE AND INTERNATIONAL QUANTUM ELECTRONICS CONFERENCE (CLEO EUROPE/IQEC), 2013,
  • [46] Screening for previous refractive surgery in eye bank corneas by using optical coherence tomography
    Lin, Roger C.
    Li, Yan
    Tang, Maolong
    McLain, Marcy
    Rollins, Andrew M.
    Izatt, Joseph A.
    Huang, David
    CORNEA, 2007, 26 (05) : 594 - 599
  • [47] Optical quality after refractive corneal surgery
    Kohnen, T
    Bühren, J
    Cichocki, M
    Kasper, T
    Terzi, E
    Ohrloff, C
    OPHTHALMOLOGE, 2006, 103 (03): : 184 - 191
  • [48] Corneal Epithelium Thickness and Refractive Changes After Myopic Laser Corneal Refractive Surgery
    Canto-Cerdan, Mario
    El Bahrawy, Mohamed
    Alio, Jorge L.
    Casanova, Laura
    Garcia, Maria J.
    Al-Amri, Saad Abdulrahman J.
    Cavas, Francisco
    Alio del Barrio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (09) : 602 - +
  • [49] Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography
    Tang, Maolong
    Li, Yan
    Avila, Mariana
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11): : 1843 - 1850
  • [50] Corneal, limbal, and conjunctival epithelial thickness from Optical Coherence Tomography
    Feng, Yunwei
    Simpson, Trefford L.