Optical Coherence Tomography Accurately Measures Corneal Power Change from Laser Refractive Surgery

被引:30
|
作者
McNabb, Ryan P. [1 ,2 ]
Farsiu, Sina [1 ,2 ]
Stinnett, Sandra S. [2 ,3 ]
Izatt, Joseph A. [1 ,2 ]
Kuo, Anthony N. [2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] Duke Univ, Dept Ophthalmol, Durham, NC USA
[3] Duke Univ, Dept Biostat & Informat, Durham, NC USA
基金
美国国家卫生研究院;
关键词
INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; MYOPIC PHOTOREFRACTIVE KERATECTOMY; REQUIRING CATARACT-SURGERY; ANTERIOR SEGMENT; VOLUMETRIC SDOCT; BIOMETRY; EYES; FORMULA; VIVO;
D O I
10.1016/j.ophtha.2014.10.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the ability of motion-corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to LASIK. Design: Evaluation of a diagnostic test or technology in a cohort. Subjects: A total of 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. A total of 39 eyes from 22 subjects were measured postoperatively and completed the study. Methods: Consecutive patients undergoing LASIK at the Duke Eye Center who consented to participate were imaged with Placido-ring topography, Scheimpflug photography, and OCT on the day of their surgery. Patients were then reimaged with the same imaging systems at the postoperative month 3 visit. Change in preoperative to postoperative corneal refractive power as measured by each of the imaging modalities was compared with the preoperative to postoperative change in manifest refraction (MRx) using the t test with generalized estimating equations. Main Outcome Measures: Corneal refractive power change due to LASIK as measured by Placido-ring topography, Scheimpflug photography, and OCT compared with the MRx change vertexed to the corneal plane. The change in MRx should correspond to the change in the corneal refractive power from LASIK and was considered the reference measurement. Results: In 22 individuals (39 eyes) returning after LASIK, we found no significant difference between the clinically measured pre- to post-LASIK change in MRx and both Scheimpflug photography (P = 0.714) and OCT (P = 0.216). In contrast, keratometry values from Placido-ring topography were found to be significantly different from the measured refractive change (P < 0.001). In addition, of the 3 imaging modalities, OCT recorded the smallest mean absolute difference from the reference measurement with the least amount of variability. Conclusions: Motion-corrected OCT more accurately measures the change in corneal refractive power due to laser refractive surgery than other currently available clinical devices. By offering accurate corneal refractive power measurements in normal and surgically modified subjects, OCT offers a compelling alternative to current clinical devices for determining corneal refractive power. (C) 2015 by the American Academy of Ophthalmology.
引用
收藏
页码:677 / 686
页数:10
相关论文
共 50 条
  • [21] Corneal dystrophies in optical coherence tomography
    Elhardt, C.
    Priglinger, S. G.
    Karakolova, Y.
    Mayer, W. J.
    Wertheimer, C.
    OPHTHALMOLOGE, 2019, 116 (09): : 857 - 864
  • [22] Femtosecond laser corneal refractive surgery
    Kurtz, R
    Spooner, G
    Sletten, K
    Yen, K
    Sayegh, S
    Loesel, F
    Horvath, C
    Liu, HH
    Elner, V
    Cabrera, D
    Meunier, MH
    Sacks, Z
    Juhasz, T
    OPHTHALMIC TECHNOLOGIES IX, PROCEEDINGS OF, 1999, 3591 : 209 - 219
  • [23] Laser refractive surgery in corneal dystrophies
    Rocha-de-Lossada, Carlos
    Rachwani-Anil, Rahul
    Colmenero-Reina, Elvira
    Borroni, Davide
    Sanchez-Gonzalez, Jose-Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (05): : 662 - 670
  • [24] Femtosecond laser in refractive corneal surgery
    Sarah Moussa
    Marie Dietrich
    Markus Lenzhofer
    Josef Ruckhofer
    Herbert A. Reitsamer
    Photochemical & Photobiological Sciences, 2019, 18 : 1669 - 1674
  • [25] The excimer laser system for refractive surgery assisted by optical coherence tomograph
    Bagayev, SN
    Gelikonov, VM
    Kargapoltsev, ES
    Kuranov, RV
    Razhev, AM
    Turchin, EV
    Zhupikov, AA
    LASER PHYSICS, 2001, 11 (11) : 1224 - 1227
  • [26] Femtosecond laser in refractive corneal surgery
    Moussa, Sarah
    Dietrich, Marie
    Lenzhofer, Markus
    Ruckhofer, Josef
    Reitsamer, Herbert A.
    PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2019, 18 (07) : 1669 - 1674
  • [27] Multiphoton imaging of corneal tissue with near-infrared femtosecond laser pulses: Corneal optical tomography and its use in refractive surgery
    Wang, Bao-Gui
    Koenig, Karsten
    Riemann, Iris
    Schubert, Harald
    Halbhuber, Karl-Juergen
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES VI, 2006, 6089
  • [28] Optical coherence tomography monitoring for laser surgery of laryngeal carcinoma
    Shakhov, AV
    Terentjeva, AB
    Kamensky, VA
    Snopova, LB
    Gelikonov, VM
    Feldchtein, FI
    Sergeev, AM
    JOURNAL OF SURGICAL ONCOLOGY, 2001, 77 (04) : 253 - 258
  • [29] Corneal topography from spectral optical coherence tomography (sOCT)
    Ortiz, Sergio
    Siedlecki, Damian
    Perez-Merino, Pablo
    Chia, Noelia
    de Castro, Alberto
    Szkulmowski, Maciej
    Wojtkowski, Maciej
    Marcos, Susana
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (12): : 3232 - 3247
  • [30] Measuring Corneal Epithelial Thickness Change after LASIK with Optical Coherence Tomography
    Tang, Maolong
    Li, Yan
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)