Optical Coherence Tomography Accurately Measures Corneal Power Change from Laser Refractive Surgery

被引:30
|
作者
McNabb, Ryan P. [1 ,2 ]
Farsiu, Sina [1 ,2 ]
Stinnett, Sandra S. [2 ,3 ]
Izatt, Joseph A. [1 ,2 ]
Kuo, Anthony N. [2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] Duke Univ, Dept Ophthalmol, Durham, NC USA
[3] Duke Univ, Dept Biostat & Informat, Durham, NC USA
基金
美国国家卫生研究院;
关键词
INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; MYOPIC PHOTOREFRACTIVE KERATECTOMY; REQUIRING CATARACT-SURGERY; ANTERIOR SEGMENT; VOLUMETRIC SDOCT; BIOMETRY; EYES; FORMULA; VIVO;
D O I
10.1016/j.ophtha.2014.10.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the ability of motion-corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to LASIK. Design: Evaluation of a diagnostic test or technology in a cohort. Subjects: A total of 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. A total of 39 eyes from 22 subjects were measured postoperatively and completed the study. Methods: Consecutive patients undergoing LASIK at the Duke Eye Center who consented to participate were imaged with Placido-ring topography, Scheimpflug photography, and OCT on the day of their surgery. Patients were then reimaged with the same imaging systems at the postoperative month 3 visit. Change in preoperative to postoperative corneal refractive power as measured by each of the imaging modalities was compared with the preoperative to postoperative change in manifest refraction (MRx) using the t test with generalized estimating equations. Main Outcome Measures: Corneal refractive power change due to LASIK as measured by Placido-ring topography, Scheimpflug photography, and OCT compared with the MRx change vertexed to the corneal plane. The change in MRx should correspond to the change in the corneal refractive power from LASIK and was considered the reference measurement. Results: In 22 individuals (39 eyes) returning after LASIK, we found no significant difference between the clinically measured pre- to post-LASIK change in MRx and both Scheimpflug photography (P = 0.714) and OCT (P = 0.216). In contrast, keratometry values from Placido-ring topography were found to be significantly different from the measured refractive change (P < 0.001). In addition, of the 3 imaging modalities, OCT recorded the smallest mean absolute difference from the reference measurement with the least amount of variability. Conclusions: Motion-corrected OCT more accurately measures the change in corneal refractive power due to laser refractive surgery than other currently available clinical devices. By offering accurate corneal refractive power measurements in normal and surgically modified subjects, OCT offers a compelling alternative to current clinical devices for determining corneal refractive power. (C) 2015 by the American Academy of Ophthalmology.
引用
收藏
页码:677 / 686
页数:10
相关论文
共 50 条
  • [1] Re: McNabb et al.: Optical coherence tomography accurately measures corneal power change from laser refractive surgery (Ophthalmology 2015;122:677-86)
    Lanza, Michele
    OPHTHALMOLOGY, 2016, 123 (01) : E5 - E6
  • [2] Re: McNabb et al.: Optical coherence tomography accurately measures corneal power change from laser refractive surgery (Ophthalmology 2015;122:677-86) REPLY
    McNabb, Ryan P.
    Farsiu, Sina
    Stinnett, Sandra S.
    Izatt, Joseph A.
    Kuo, Anthony N.
    OPHTHALMOLOGY, 2016, 123 (01) : E6 - E7
  • [3] Optical coherence tomography in cornea and refractive surgery
    Hurmeric, Volkan
    Yoo, Sonia H.
    Mutlu, Fatih Mehmet
    EXPERT REVIEW OF OPHTHALMOLOGY, 2012, 7 (03) : 241 - 250
  • [4] Longitudinal Evaluation of Posterior Corneal Elevation after Laser Refractive Surgery Using Swept-Source Optical Coherence Tomography
    Chan, Tommy C. Y.
    Liu, Dexter
    Yu, Marco
    Jhanji, Vishal
    OPHTHALMOLOGY, 2015, 122 (04) : 687 - 692
  • [5] A new method to accurately assess post-laser-surgery refractive changes with the intrinsic corneal power changes
    Liu, Yongji
    Wang, Zhaoqi
    Wang, Yan
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S825 - S832
  • [6] Experimental evaluation of online optical coherence pachymetry for corneal refractive surgery
    Christopher Wirbelauer
    Henning Aurich
    Jan Jaroszewski
    Christian Hartmann
    Duy Thoai Pham
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2004, 242 : 24 - 30
  • [7] Experimental evaluation of online optical coherence pachymetry for corneal refractive surgery
    Wirbelauer, C
    Aurich, H
    Jaroszewski, J
    Hartmann, C
    Pham, DT
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2004, 242 (01) : 24 - 30
  • [8] Optical coherence tomography of clear corneal incisions for cataract surgery
    Schallhorn, Julie M.
    Tang, Maolong
    Li, Yan
    Song, Jonathan C.
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09): : 1561 - 1565
  • [9] Role of Optical Coherence Tomography on Corneal Surface Laser Ablation
    Ventura, Bruna V.
    Moraes, Haroldo V., Jr.
    Kara-Junior, Newton
    Santhiago, Marcony R.
    JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [10] Optical coherence tomography for in situ monitoring of laser corneal ablation
    Bagayev, SN
    Gelikonov, VM
    Gelikonov, GV
    Kargapoltsev, ES
    Kuranov, RV
    Razhev, AM
    Turchin, IV
    Zhupikov, AA
    JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (04) : 633 - 642