Physiological Responses to Wearing a Prototype Firefighter Ensemble Compared with a Standard Ensemble

被引:17
|
作者
Williams, W. Jon [1 ]
Coca, Aitor [1 ]
Roberge, Raymond [1 ]
Shepherd, Angie [1 ]
Powell, Jeffrey [1 ]
Shaffer, Ronald E. [1 ]
机构
[1] NIOSH, Natl Personal Protect Technol Lab, Ctr Dis Control & Prevent, Pittsburgh, PA 15236 USA
关键词
core body temperature; firefighter; heat stress; skin temperature; sweat rates; FIRE FIGHTERS; HUMAN-BODY; HEAT; EXERCISE; VEST; STRAIN; REDUCTION; STRESS; WORK; AIR;
D O I
10.1080/15459624.2011.538358
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated the physiological responses to wearing a standard firefighter ensemble (SE) and a prototype ensemble (PE) modified from the SE that contained additional features, such as magnetic ring enclosures at the glove-sleeve interface, integrated boot-pant interface, integrated hood-SCBA facepiece interface, and a novel hose arrangement that rerouted self-contained breathing apparatus (SCBA) exhaust gases back into the upper portion of the jacket. Although the features of the PE increased the level of encapsulation of the wearer that could lead to increased physiological stress compared with the SE, it was hypothesized that the rerouted exhaust gases provided by the PE hose assembly would (1) provide convective cooling to the upper torso, (2) reduce the thermal stress experienced by the wearer, and (3) reduce the overall physiological stress imposed by the PE such that it would be either less or not significantly different from the SE. Ten subjects (seven male, three female) performed treadmill exercise in an environmental chamber (22 degrees C, 50% RH) at 50%. (V) over dot O-2max while wearing either the SE with an SCBA or the PE with an SCBA either with or without the hose attached (designated PEWH and PENH, respectively). Heart rate (HR), rectal and intestinal temperatures (T-re, T-in), sweat loss, and endurance time were measured. All subjects completed at least 20 min of treadmill exercise during the testing. At the end of exercise, there was no difference in T-re (p = 0.45) or T-in (p = 0.42), HR, or total sweat loss between the SE and either PEWH or PENH (p = 0.59). However, T-sk was greater in PEWH and PENH compared with SE (p < 0.05). Total endurance time in SE was greater than in either PEWH or PENH (p < 0.05). Thus, it was concluded that the rerouting of exhaust gases to the jacket did not provide significant convective cooling or reduce thermal stress compared with the SE under the mild conditions selected, and the data did not support the hypotheses of the present study.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [31] Dispersion modeling using ensemble forecasts compared to ETEX measurements
    Straume, AG
    Koffi, EN
    Nodop, K
    JOURNAL OF APPLIED METEOROLOGY, 1998, 37 (11): : 1444 - 1456
  • [32] Reproducibility of Physiological Measures in Protective Ensemble User Performance Testing
    Kim, Jung-Hyun
    Coca, Aitor
    Williams, W. Jon
    Roberge, Raymond
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 679 - 680
  • [33] Ensemble Learning Based Gender Recognition from Physiological Signals
    Zhang, Huiling
    Guo, Ning
    Liu, Guangyuan
    Hu, Junhao
    Zhou, Jiaxiu
    Feng, Shengzhong
    Wei, Yanjie
    BIG DATA - BIGDATA 2018, 2018, 10968 : 352 - 359
  • [34] Reproducibility of Physiological Measures in Protective Ensemble User Performance Testing
    Kim, Jung-Hyun
    Coca, Aitor
    Williams, W. Jon
    Roberge, Raymond
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 679 - 680
  • [35] Visualization and Classification of Physiological Failure Modes in Ensemble Hemorrhage Simulation
    Zhang, Song
    Pruett, William Andrew
    Hester, Robert
    VISUALIZATION AND DATA ANALYSIS 2015, 2015, 9397
  • [36] Physiological Monitoring in Firefighter Ensembles: Wearable Plethysmographic Sensor Vest versus Standard Equipment
    Coca, Aitor
    Roberge, Raymond J.
    Williams, W. Jon
    Landsittel, Douglas P.
    Powell, Jeffrey B.
    Palmiero, Andrew
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2010, 7 (02) : 109 - 114
  • [37] Simultaneous quantification of the fluorescent responses of an ensemble of bacterial sensors
    Kabessa, Yossef
    Korouma, Victor
    Ilan, Har'el
    Yagur-Kroll, Sharon
    Belkin, Shimshon
    Agranat, Aharon J.
    BIOSENSORS & BIOELECTRONICS, 2013, 49 : 394 - 398
  • [38] Echo responses of an ensemble of cold atoms in optical lattices
    Elyutin, SO
    OPTICS AND SPECTROSCOPY, 2005, 98 (04) : 605 - 617
  • [39] Echo responses of an ensemble of cold atoms in optical lattices
    S. O. Elyutin
    Optics and Spectroscopy, 2005, 98 : 605 - 617
  • [40] Unsupervised Cross-Modal Medical Image Retrieval with Ensemble Prototype Alignment
    Yao, Yishan
    Liu, Xiaoqing
    Yu, Zhiwen
    Lv, Jianming
    Hu, Yang
    Yang, Kaixiang
    2024 IEEE INTERNATIONAL CONFERENCE ON MEDICAL ARTIFICIAL INTELLIGENCE, MEDAI 2024, 2024, : 161 - 167