core body temperature; firefighter; heat stress; skin temperature; sweat rates; FIRE FIGHTERS; HUMAN-BODY; HEAT; EXERCISE; VEST; STRAIN; REDUCTION; STRESS; WORK; AIR;
D O I
10.1080/15459624.2011.538358
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated the physiological responses to wearing a standard firefighter ensemble (SE) and a prototype ensemble (PE) modified from the SE that contained additional features, such as magnetic ring enclosures at the glove-sleeve interface, integrated boot-pant interface, integrated hood-SCBA facepiece interface, and a novel hose arrangement that rerouted self-contained breathing apparatus (SCBA) exhaust gases back into the upper portion of the jacket. Although the features of the PE increased the level of encapsulation of the wearer that could lead to increased physiological stress compared with the SE, it was hypothesized that the rerouted exhaust gases provided by the PE hose assembly would (1) provide convective cooling to the upper torso, (2) reduce the thermal stress experienced by the wearer, and (3) reduce the overall physiological stress imposed by the PE such that it would be either less or not significantly different from the SE. Ten subjects (seven male, three female) performed treadmill exercise in an environmental chamber (22 degrees C, 50% RH) at 50%. (V) over dot O-2max while wearing either the SE with an SCBA or the PE with an SCBA either with or without the hose attached (designated PEWH and PENH, respectively). Heart rate (HR), rectal and intestinal temperatures (T-re, T-in), sweat loss, and endurance time were measured. All subjects completed at least 20 min of treadmill exercise during the testing. At the end of exercise, there was no difference in T-re (p = 0.45) or T-in (p = 0.42), HR, or total sweat loss between the SE and either PEWH or PENH (p = 0.59). However, T-sk was greater in PEWH and PENH compared with SE (p < 0.05). Total endurance time in SE was greater than in either PEWH or PENH (p < 0.05). Thus, it was concluded that the rerouting of exhaust gases to the jacket did not provide significant convective cooling or reduce thermal stress compared with the SE under the mild conditions selected, and the data did not support the hypotheses of the present study.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [21] HEAT-STORAGE WITH HARD WORK WHILE WEARING THE CHEMICAL DEFENSE ENSEMBLE
    CONSTABLE, SH
    BISHOP, P
    NUNNELEY, SA
    GARZA, J
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1988, 59 (05): : 491 - 491
  • [22] A deep learning-based ensemble method for helmet-wearing detection
    Fan, Zheming
    Peng, Chengbin
    Dai, Licun
    Cao, Feng
    Qi, Jianyu
    Hua, Wenyi
    PEERJ COMPUTER SCIENCE, 2020, PeerJ Inc. (06) : 1 - 21
  • [23] Temperature rating prediction of Tibetan robe ensemble based on different wearing ways
    Li, Jun
    Guo, Xiaofang
    Wang, Yunyi
    APPLIED ERGONOMICS, 2012, 43 (05) : 909 - 915
  • [24] AMPLIFICATION OF PULSE RESPONSES IN ENSEMBLE OF NONLINEAR OSCILLATORS
    CHEBOTAYEV, VP
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1990, 51 (04): : 303 - 306
  • [25] Electricity Theft Detection Method Based on Ensemble Learning and Prototype Learning
    Sun, Xinwu
    Hu, Jiaxiang
    Zhang, Zhenyuan
    Cao, Di
    Huang, Qi
    Chen, Zhe
    Hu, Weihao
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2024, 12 (01) : 213 - 224
  • [26] Analyzing different prototype selection techniques for dynamic classifier and ensemble selection
    Cruz, Rafael M. O.
    Sabourin, Robert
    Cavalcanti, George D. C.
    2017 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2017, : 3959 - 3966
  • [27] Electricity Theft Detection Method Based on Ensemble Learning and Prototype Learning
    Xinwu Sun
    Jiaxiang Hu
    Zhenyuan Zhang
    Di Cao
    Qi Huang
    Zhe Chen
    Weihao Hu
    Journal of Modern Power Systems and Clean Energy, 2024, 12 (01) : 213 - 224
  • [28] Fuzzy Ensemble Clustering Based on Self-Coassociation and Prototype Propagation
    Li, Feijiang
    Wang, Jieting
    Qian, Yuhua
    Liu, Guoqing
    Wang, Keqi
    IEEE TRANSACTIONS ON FUZZY SYSTEMS, 2023, 31 (10) : 3610 - 3623
  • [29] The added value of convection-permitting ensemble forecasts of sea breeze compared to a Bayesian forecast driven by the global ensemble
    Cafaro, Carlo
    Frame, Thomas H. A.
    Methven, John
    Roberts, Nigel
    Brocker, Jochen
    QUARTERLY JOURNAL OF THE ROYAL METEOROLOGICAL SOCIETY, 2019, 145 (721) : 1780 - 1798
  • [30] Firefighter Physiological Responses To Increased Self Contained Breathing Apparatus (SCBA) Weight
    Powell, Jeffrey B.
    Xu, Susan
    Zhuang, Ziqing
    Kessler, Richard
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 857 - 857