Multiplex label-free biosensor for detection of autoantibodies in human serum: Tool for new kinetics-based diagnostics of autoimmune diseases

被引:35
|
作者
Orlov, A., V [1 ,2 ]
Pushkarev, A., V [1 ,2 ]
Znoyko, S. L. [1 ]
Novichikhin, D. O. [1 ,3 ]
Bragina, V. A. [1 ]
Gorshkov, B. G. [1 ]
Nikitin, P., I [1 ,3 ]
机构
[1] Russian Acad Sci, Prokhorov Gen Phys Inst, 38 Vavilov St, Moscow 119991, Russia
[2] Natl Res Univ, Moscow Inst Phys & Technol, 9 Inst Skii Per, Dolgoprudnyi 141700, Moscow Region, Russia
[3] Natl Res Nucl Univ MEPhI, Moscow Engn Phys Inst, 31 Kashirskoe Shosse, Moscow 115409, Russia
来源
基金
俄罗斯科学基金会;
关键词
Label-free biosensing; Diagnostics of autoimmune diseases; Autoantibody activity; Surface-induced conformational changes; Human serum; OPTICAL BIOSENSORS; IMMOBILIZATION; RESONANCE; AFFINITY; SPR; PLATFORM; AVIDITY; DESIGN;
D O I
10.1016/j.bios.2020.112187
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A multiplex label-free biosensor is developed for diagnostics of autoimmune diseases by highly sensitive measuring in human serum both critical characteristics of autoantibody: concentration and native kinetic parameters that reflect autoantibody aggressiveness to the organism's tissues. The biosensor is based on the spectral-correlation interferometry and image processing of a microarray glass biochip, affordable to be single-used in medical applications. Simultaneous 25-min detection and activity characterization of several autoantibodies in the same serum sample have been demonstrated for anti-thymglobulin (anti-TG) and anti-thyroid pemxidase (anti-TPO) as models. The biosensor offers extremely high sensitivity: limits of detection in serum are 1.7 IU/mL and 6 IU/mL for anti-TPO and anti-TG, respectively. The dynamic range covers the whole range of clinically relevant concentrations of the autoantibodies up to 1000 IU/mL. The developed method of characterization of autoantibody activity by recording the kinetics of their binding with free native antigens is based on autoantibody polyvalency. The measurements in clinical serum samples have shown that the native kinetic parameters are independent of concentration. The proposed biosensor and method of native kinetic registration can be used to develop new criteria for comprehensive diagnostics of autoimmune diseases, based not only on traditional measurements of concentration but also on quantitative evaluation of autoantibody aggressiveness. The developed method can be adapted to other label-free sensors such as those based on the surface plasmon resonance, optical waveguides, etc.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Label-free detection of cardiac biomarker using aptamer based capacitive biosensor
    Qureshi, Anjum
    Gurbuz, Yasar
    Niazi, Javed H.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 828 - 830
  • [32] A novel label-free bioengineered cell-based biosensor for salicin detection
    Hu, Liang
    Zou, Lin
    Qin, Zhen
    Fang, Jiaru
    Huang, Liquan
    Wang, Ping
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 1151 - 1158
  • [33] On-chip-based electrochemical biosensor for the sensitive and label-free detection of Cryptosporidium
    Luka, George S.
    Najjaran, Homayoun
    Hoorfar, Mina
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [34] A silicon-based peptide biosensor for label-free detection of cancer cells
    Martucci, Nicola M.
    Rea, Ilaria
    Ruggiero, Immacolata
    Terracciano, Monica
    De Stefano, Luca
    Migliaccio, Nunzia
    Dardano, Principia
    Arcari, Paolo
    Rendina, Ivo
    Lamberti, Annalisa
    OPTICAL SENSORS 2015, 2015, 9506
  • [35] Highly sensitive aptamer based on electrochemiluminescence biosensor for label-free detection of bisphenol A
    Shengjie Ye
    Ruihong Ye
    Yuande Shi
    Bin Qiu
    Longhua Guo
    Dihui Huang
    Zhenyu Lin
    Guonan Chen
    Analytical and Bioanalytical Chemistry, 2017, 409 : 7145 - 7151
  • [36] Detection of Oxytetracycline Using an Electrochemical Label-Free Aptamer-Based Biosensor
    Akbarzadeh, Sanaz
    Khajehsharifi, Habibollah
    Hajihosseini, Saeedeh
    BIOSENSORS-BASEL, 2022, 12 (07):
  • [37] Biomimetic Nanopillar-Based Biosensor for Label-Free Detection of Influenza A Virus
    Lee, Wang Sik
    Ahn, Junhyoung
    Jung, Sanghee
    Lee, Jaejong
    Kang, Taejoon
    Jeong, Jinyoung
    BIOCHIP JOURNAL, 2021, 15 (03) : 260 - 267
  • [38] A Label-Free Biosensor for Protein Detection Based on Ring Slots in a Photonic Crystal
    Bilal Tebboub
    Amel Labbani
    Fatima Brik
    Journal of Russian Laser Research, 2022, 43 : 307 - 314
  • [39] AlGaN/GaN-based biosensor for label-free detection of biological activity
    Podolska, A.
    Hool, L. C.
    Pfleger, K. D. G.
    Mishra, U. K.
    Parish, G.
    Nener, B. D.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 577 - 582
  • [40] On-chip-based electrochemical biosensor for the sensitive and label-free detection of Cryptosporidium
    George S. Luka
    Homayoun Najjaran
    Mina Hoorfar
    Scientific Reports, 12