Multiplex label-free biosensor for detection of autoantibodies in human serum: Tool for new kinetics-based diagnostics of autoimmune diseases

被引:35
|
作者
Orlov, A., V [1 ,2 ]
Pushkarev, A., V [1 ,2 ]
Znoyko, S. L. [1 ]
Novichikhin, D. O. [1 ,3 ]
Bragina, V. A. [1 ]
Gorshkov, B. G. [1 ]
Nikitin, P., I [1 ,3 ]
机构
[1] Russian Acad Sci, Prokhorov Gen Phys Inst, 38 Vavilov St, Moscow 119991, Russia
[2] Natl Res Univ, Moscow Inst Phys & Technol, 9 Inst Skii Per, Dolgoprudnyi 141700, Moscow Region, Russia
[3] Natl Res Nucl Univ MEPhI, Moscow Engn Phys Inst, 31 Kashirskoe Shosse, Moscow 115409, Russia
来源
基金
俄罗斯科学基金会;
关键词
Label-free biosensing; Diagnostics of autoimmune diseases; Autoantibody activity; Surface-induced conformational changes; Human serum; OPTICAL BIOSENSORS; IMMOBILIZATION; RESONANCE; AFFINITY; SPR; PLATFORM; AVIDITY; DESIGN;
D O I
10.1016/j.bios.2020.112187
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A multiplex label-free biosensor is developed for diagnostics of autoimmune diseases by highly sensitive measuring in human serum both critical characteristics of autoantibody: concentration and native kinetic parameters that reflect autoantibody aggressiveness to the organism's tissues. The biosensor is based on the spectral-correlation interferometry and image processing of a microarray glass biochip, affordable to be single-used in medical applications. Simultaneous 25-min detection and activity characterization of several autoantibodies in the same serum sample have been demonstrated for anti-thymglobulin (anti-TG) and anti-thyroid pemxidase (anti-TPO) as models. The biosensor offers extremely high sensitivity: limits of detection in serum are 1.7 IU/mL and 6 IU/mL for anti-TPO and anti-TG, respectively. The dynamic range covers the whole range of clinically relevant concentrations of the autoantibodies up to 1000 IU/mL. The developed method of characterization of autoantibody activity by recording the kinetics of their binding with free native antigens is based on autoantibody polyvalency. The measurements in clinical serum samples have shown that the native kinetic parameters are independent of concentration. The proposed biosensor and method of native kinetic registration can be used to develop new criteria for comprehensive diagnostics of autoimmune diseases, based not only on traditional measurements of concentration but also on quantitative evaluation of autoantibody aggressiveness. The developed method can be adapted to other label-free sensors such as those based on the surface plasmon resonance, optical waveguides, etc.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Aptamer-Based Label-Free Impedimetric Biosensor for Detection of Progesterone
    Jimenez, Gaston Contreras
    Eissa, Shimaa
    Ng, Andy
    Alhadrami, Hani
    Zourob, Mohammed
    Siaj, Mohamed
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1075 - 1082
  • [22] Label-free visual biosensor based on cascade amplification for the detection of Salmonella
    Zhang, Yuan
    Tian, Jingjing
    Li, Kai
    Tian, Hongtao
    Xu, Wentao
    ANALYTICA CHIMICA ACTA, 2019, 1075 : 144 - 151
  • [23] Electrochemical Estrogen Receptor a based Biosensor for Label-Free Detection of Estradiol
    Guo, Zhenzhong
    Zine, Nadia
    Balaguer, Patrick
    Zhang, Aidong
    Namour, Philippe
    Lagarde, Florence
    Jaffrezic-Renault, Nicole
    ELECTROANALYSIS, 2013, 25 (07) : 1765 - 1772
  • [24] Label-free detection of lysozyme in wines using an aptamer based biosensor and SPR detection
    Mihai, Luliana
    Vezeanu, Alis
    Polonschii, Cristina
    Albu, Camelia
    Radu, Gabriel-Lucian
    Vasilescu, Alina
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 198 - 204
  • [25] Ultrasensitive detection of PrPC in human serum using label-free electrochemical biosensor based on α-iron trioxide/ferriferrous oxide magnetic nanocomposites
    Zhang, Haoda
    Lv, Zhixiang
    Zhang, Hexiao
    Zhang, Yunxiao
    He, Dawei
    Liu, Ruijiang
    MICROCHEMICAL JOURNAL, 2025, 212
  • [26] Label-Free and Bioluminescence-Based Nano-Biosensor for ATP Detection
    Karimi, Elham
    Nikkhah, Maryam
    Hosseinkhani, Saman
    BIOSENSORS-BASEL, 2022, 12 (11):
  • [27] Label-free aptamer biosensor for thrombin detection based on functionalized graphene nanocomposites
    Wang, Qingqing
    Zhou, Zhixue
    Zhai, Yanling
    Zhang, Lingling
    Hong, Wei
    Zhang, Zhiquan
    Dong, Shaojun
    TALANTA, 2015, 141 : 247 - 252
  • [28] Biomimetic nanochannels based biosensor for ultrasensitive and label-free detection of nucleic acids
    Sun, Zhongyue
    Liao, Tangbin
    Zhang, Yulin
    Shu, Jing
    Zhang, Hong
    Zhang, Guo-Jun
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 194 - 201
  • [29] Label-free detection of bovine serum albumin based on an in-fiber Mach-Zehnder interferometric biosensor
    Li, Zhengyong
    Liao, Changrui
    Chen, Danni
    Song, Jun
    Jin, Wei
    Peng, Gang-Ding
    Zhu, Feng
    Wang, Ying
    He, Jun
    Wang, Yiping
    OPTICS EXPRESS, 2017, 25 (15): : 17105 - 17113
  • [30] Biomimetic Nanopillar-Based Biosensor for Label-Free Detection of Influenza A Virus
    Wang Sik Lee
    Junhyoung Ahn
    Sanghee Jung
    Jaejong Lee
    Taejoon Kang
    Jinyoung Jeong
    BioChip Journal, 2021, 15 : 260 - 267