Helical tomotherapy and intensity modulated proton therapy in the treatment of early stage prostate cancer: A treatment planning comparison

被引:28
|
作者
Schwarz, Marco [1 ]
Pierelli, Alessio [2 ]
Fiorino, Claudio [2 ]
Fellin, Francesco [1 ]
Cattaneo, Giovanni Mauro [2 ]
Cozzarini, Cesare [2 ]
Di Muzio, Nadia [2 ]
Calandrino, Riccardo [2 ]
Widesott, Lamberto [1 ]
机构
[1] Agenzia Prov Protonterapia, I-38122 Trento, Italy
[2] Ist Sci San Raffaele, Milan, Italy
关键词
IMPT; Tomotherapy; Prostate; Planning comparison; DOSE-ESCALATION TRIAL; X-RAY THERAPY; CONFORMAL RADIOTHERAPY; IMAGE-GUIDANCE; VOLUME; IMRT; OPTIMIZATION; MULTICENTER; ISSUES; TUMORS;
D O I
10.1016/j.radonc.2010.10.027
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare helical tomotherapy (HT) and intensity modulated proton therapy (IMPT) on early stage prostate cancer treatments delivered with simultaneous integrated boost (SIB) in moderate hypofractionation. Material/methods: Eight patients treated with HT were replanned with two-field IMPT (2fIMPT) and five-field IMPT (5fIMPT), using a small pencil beam size (3 mm sigma). The prescribed dose was 74.3 Gy in 28 fractions on PTV1 (prostate) and PTV2 (proximal seminal vesicles), 65.5 Gy on PTV3 (distal seminal vesicles) and on the overlap between rectum and PTVs. Results: IMPT and HT achieved similar target coverage and dose homogeneity, with 5fIMPT providing the best results. The conformity indexes of IMPT were significantly lower for PTV1+2 and PTV3. Above 65 Gy, HT and IMPT were equivalent in the rectum, while IMPT spared the bladder and the penile bulb from 0 to 70 Gy. From 0 up to 60 Gy, IMPT dosimetric values were (much) lower for all OARs except the femur heads, where HT was better than 2fIMPT in the 25-35 Gy dose range. OARs mean doses were typically reduced by 30-50% by IMPT. NTCPs for the rectum were within 1% between the two techniques, except when the endpoint was stool frequency, where IMPT showed a small (though statistically significant) benefit. Conclusions: HT and IMPT produce similar dose distributions in the target volume. The current knowledge on dose-effect relations does not allow to quantify the clinical impact of the large sparing of IMPT at medium-to-low doses. (C) 2010 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 98 (2011) 74-80
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [41] Which technique for radiation is most beneficial for patients with locally advanced cervical cancer? Intensity modulated proton therapy versus intensity modulated photon treatment, helical tomotherapy and volumetric arc therapy for primary radiation – an intraindividual comparison
    Simone Marnitz
    Waldemar Wlodarczyk
    Oliver Neumann
    Christhardt Koehler
    Mirko Weihrauch
    Volker Budach
    Luca Cozzi
    Radiation Oncology, 10
  • [42] Which technique for radiation is most beneficial for patients with locally advanced cervical cancer? Intensity modulated proton therapy versus intensity modulated photon treatment, helical tomotherapy and volumetric arc therapy for primary radiation - an intraindividual comparison
    Marnitz, Simone
    Wlodarczyk, Waldemar
    Neumann, Oliver
    Koehler, Christhardt
    Weihrauch, Mirko
    Budach, Volker
    Cozzi, Luca
    RADIATION ONCOLOGY, 2015, 10
  • [43] Dosimetric Comparison of Intensity-Modulated Radiosurgery and Helical Tomotherapy for the Treatment of Multiple Intracranial Metastases
    VanderSpek, Lauren
    Bauman, Glenn
    Wang, Jia-Zhu
    Yartsev, Slav
    Menard, Cynthia
    Cho, Young-Bin
    Mundt, Arno J.
    Lawson, Joshua D.
    Murphy, Kevin T.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (05) : 361 - 367
  • [44] Comparison of volumetric modulated arc therapy and helical tomotherapy for prostate cancer using Pareto fronts
    Wuthrich, Diana
    Wang, Zirun
    Zeverino, Michele
    Bourhis, Jean
    Bochud, Francois
    Moeckli, Raphal
    MEDICAL PHYSICS, 2024, 51 (04) : 3010 - 3019
  • [45] Dosimetric comparison of TomoDirect, helical tomotherapy, and volumetric modulated arc therapy for postmastectomy treatment
    Nobnop, Wannapha
    Phakoetsuk, Panchalee
    Chitapanarux, Imjai
    Tippanya, Damrongsak
    Khamchompoo, Darat
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 155 - 162
  • [46] Treatment planning comparison between conformal radiotherapy and helical tomotherapy in case of stage IIINSCLC
    Cattaneo, G
    Dell'Oca, I
    Broggi, S
    Molinelli, S
    Muzio, ND
    Messa, C
    Fazio, F
    Calandrino, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S222 - S222
  • [47] Optimization of beam parameters and treatment planning for intensity modulated proton therapy
    Trofimov, A
    Bortfeld, T
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2003, 2 (05) : 437 - 444
  • [48] A dosimetric comparison of Helical Tomotherapy and VMAT in the treatment of high risk prostate cancer
    Lacornerie, T.
    Cavillon, F.
    Hardhuin, R.
    Compte, P.
    Reynaert, N.
    Lartigau, E. F.
    Pasquier, D.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S202 - S202
  • [49] Optimization of helical tomotherapy treatment plans for prostate cancer
    Grigorov, G
    Kron, T
    Wong, E
    Chen, J
    Sollazzo, J
    Rodrigues, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (13): : 1933 - 1943
  • [50] Dosimetric comparison of volumetric-modulated arc therapy and helical tomotherapy for adjuvant treatment of bilateral breast cancer
    Phurailatpam, Reena
    Wadasadawala, Tabassum
    Chauhan, Kamalnayan
    Panda, Subhajit
    Sarin, Rajiv
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 36 - 44