Comparison of volumetric modulated arc therapy and helical tomotherapy for prostate cancer using Pareto fronts

被引:1
|
作者
Wuthrich, Diana [1 ,2 ]
Wang, Zirun [1 ,2 ]
Zeverino, Michele [1 ,2 ]
Bourhis, Jean [2 ,3 ]
Bochud, Francois [1 ,2 ]
Moeckli, Raphal [1 ,2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Lausanne Univ, Lausanne, Switzerland
[3] Lausanne Univ Hosp, Dept Radiat Oncol, Lausanne, Switzerland
关键词
helical tomotherapy (HT); multi-criteria optimization (MCO); pareto front; prostate; volumetric modulated arc therapy (VMAT); SINGLE-ARC; PLAN QUALITY; RADIOTHERAPY; IMRT; VMAT; OPTIMIZATION; IRRADIATION; TOXICITY;
D O I
10.1002/mp.16868
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundStudies comparing different radiotherapy treatment techniques-such as volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT)-typically compare one treatment plan per technique. Often, some dose metrics favor one plan and others favor the other, so the final plan decision involves subjective preferences. Pareto front comparisons provide a more objective framework for comparing different treatment techniques. A Pareto front is the set of all treatment plans where improvement in one criterion is possible only by worsening another criterion. However, different Pareto fronts can be obtained depending on the chosen machine settings.PurposeTo compare VMAT and HT using Pareto fronts and blind expert evaluation, to explain the observed differences, and to illustrate limitations of using Pareto fronts.MethodsWe generated Pareto fronts for twenty-four prostate cancer patients treated at our clinic for VMAT and HT techniques using an in-house script that controlled a commercial treatment planning system. We varied the PTV under-coverage (100% - V95%) and the rectum mean dose, and fixed the mean doses to the bladder and femoral heads. In order to ensure a fair comparison, those fixed mean doses were the same for the two treatment techniques and the sets of objective functions were chosen so that the conformity indexes of the two treatment techniques were also the same. We used the same machine settings as are used in our clinic. Then, we compared the VMAT and HT Pareto fronts using a specific metric (clinical distance measure) and validated the comparison using a blinded expert evaluation of treatment plans on these fronts for all patients in the cohort. Furthermore, we investigated the observed differences between VMAT and HT and pointed out limitations of using Pareto fronts.ResultsBoth clinical distance and blind treatment plan comparison showed that VMAT Pareto fronts were better than HT fronts. VMAT fronts for 10 and 6 MV beam energy were almost identical. HT fronts improved with different machine settings, but were still inferior to VMAT fronts.ConclusionsThat VMAT Pareto fronts are better than HT fronts may be explained by the fact that the linear accelerator can rapidly vary the dose rate. This is an advantage in simple geometries that might vanish in more complex geometries. Furthermore, one should be cautious when speaking about Pareto optimal plans as the best possible plans, as their calculation depends on many parameters.
引用
收藏
页码:3010 / 3019
页数:10
相关论文
共 50 条
  • [1] Comparison of Plan Quality Provided by Volumetric Modulated Arc Therapy and Helical Tomotherapy
    Yampolsky, H.
    Martyn, B.
    Squire, D.
    Hartwick, T.
    Botnick, M.
    Botnick, L.
    Rose, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S728 - S729
  • [2] Volumetric Modulated Arc Therapy (VMAT) Versus Helical Tomotherapy (HT) for Localized Prostate Cancer: Dosimetric Comparison by Using the Identical Prescription Dose to the Prostate
    Ayakawa, S.
    Sugie, C.
    Baba, F.
    Hayashi, A.
    Kosaki, K.
    Nonogaki, Y.
    Hasegawa, S.
    Tanaka, S.
    Komai, K.
    Shibamoto, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S375 - S375
  • [3] Comparison of intensity-modulated radiotherapy with the 5-field technique, helical tomotherapy and volumetric modulated arc therapy for localized prostate cancer
    Kita, Nozomi
    Shibamoto, Yuta
    Takemoto, Shinya
    Manabe, Yoshihiko
    Yanagi, Takeshi
    Sugie, Chikao
    Tomita, Natsuo
    Iwata, Hiromitsu
    Murai, Taro
    Hashimoto, Shingo
    Ishikura, Satoshi
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (04) : 666 - 674
  • [4] Dosimetric comparison of TomoDirect, helical tomotherapy, and volumetric modulated arc therapy for postmastectomy treatment
    Nobnop, Wannapha
    Phakoetsuk, Panchalee
    Chitapanarux, Imjai
    Tippanya, Damrongsak
    Khamchompoo, Darat
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 155 - 162
  • [5] Dosimetric comparison of volumetric-modulated arc therapy and helical tomotherapy for adjuvant treatment of bilateral breast cancer
    Phurailatpam, Reena
    Wadasadawala, Tabassum
    Chauhan, Kamalnayan
    Panda, Subhajit
    Sarin, Rajiv
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 36 - 44
  • [6] Helical tomotherapy and two types of volumetric modulated arc therapy: dosimetric and clinical comparison for several cancer sites
    Gallio, Elena
    Sardo, Anna
    Badellino, Serena
    Mantovani, Cristina
    Levis, Mario
    Fiandra, Christian
    Guarneri, Alessia
    Arcadipane, Francesca
    Richetto, Veronica
    Ricardi, Umberto
    Giglioli, Francesca Romana
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (02) : 272 - 283
  • [7] Helical tomotherapy and two types of volumetric modulated arc therapy: dosimetric and clinical comparison for several cancer sites
    Elena Gallio
    Anna Sardo
    Serena Badellino
    Cristina Mantovani
    Mario Levis
    Christian Fiandra
    Alessia Guarneri
    Francesca Arcadipane
    Veronica Richetto
    Umberto Ricardi
    Francesca Romana Giglioli
    Radiological Physics and Technology, 2023, 16 : 272 - 283
  • [8] Dosimetric Comparison of Volumetric Modulated Arc Therapy and Helical Tomotherapy for Spine Stereotactic Body Radiation Therapy
    Dandekar, V. K.
    Young, J. L.
    Turian, J.
    Diaz, A.
    Sher, D. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S725 - S725
  • [9] SmartArc-Based Volumetric Modulated Arc Therapy for Endometrial Cancer: A Dosimetric Comparison with Helical Tomotherapy and Intensity-Modulated Radiation Therapy
    Yang, R.
    Wang, J.
    Xu, S.
    Li, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Helical tomotherapy and volumetric modulated arc therapy: New therapeutic arms in the breast cancer radiotherapy
    Lauche, Olivier
    Kirova, Youlia M.
    Fenoglietto, Pascal
    Costa, Emilie
    Lemanski, Claire
    Bourgier, Celine
    Riou, Olivier
    Tiberi, David
    Campana, Francois
    Fourquet, Alain
    Azria, David
    WORLD JOURNAL OF RADIOLOGY, 2016, 8 (08): : 735 - 742