Comparison of volumetric modulated arc therapy and helical tomotherapy for prostate cancer using Pareto fronts

被引:1
|
作者
Wuthrich, Diana [1 ,2 ]
Wang, Zirun [1 ,2 ]
Zeverino, Michele [1 ,2 ]
Bourhis, Jean [2 ,3 ]
Bochud, Francois [1 ,2 ]
Moeckli, Raphal [1 ,2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Lausanne Univ, Lausanne, Switzerland
[3] Lausanne Univ Hosp, Dept Radiat Oncol, Lausanne, Switzerland
关键词
helical tomotherapy (HT); multi-criteria optimization (MCO); pareto front; prostate; volumetric modulated arc therapy (VMAT); SINGLE-ARC; PLAN QUALITY; RADIOTHERAPY; IMRT; VMAT; OPTIMIZATION; IRRADIATION; TOXICITY;
D O I
10.1002/mp.16868
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundStudies comparing different radiotherapy treatment techniques-such as volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT)-typically compare one treatment plan per technique. Often, some dose metrics favor one plan and others favor the other, so the final plan decision involves subjective preferences. Pareto front comparisons provide a more objective framework for comparing different treatment techniques. A Pareto front is the set of all treatment plans where improvement in one criterion is possible only by worsening another criterion. However, different Pareto fronts can be obtained depending on the chosen machine settings.PurposeTo compare VMAT and HT using Pareto fronts and blind expert evaluation, to explain the observed differences, and to illustrate limitations of using Pareto fronts.MethodsWe generated Pareto fronts for twenty-four prostate cancer patients treated at our clinic for VMAT and HT techniques using an in-house script that controlled a commercial treatment planning system. We varied the PTV under-coverage (100% - V95%) and the rectum mean dose, and fixed the mean doses to the bladder and femoral heads. In order to ensure a fair comparison, those fixed mean doses were the same for the two treatment techniques and the sets of objective functions were chosen so that the conformity indexes of the two treatment techniques were also the same. We used the same machine settings as are used in our clinic. Then, we compared the VMAT and HT Pareto fronts using a specific metric (clinical distance measure) and validated the comparison using a blinded expert evaluation of treatment plans on these fronts for all patients in the cohort. Furthermore, we investigated the observed differences between VMAT and HT and pointed out limitations of using Pareto fronts.ResultsBoth clinical distance and blind treatment plan comparison showed that VMAT Pareto fronts were better than HT fronts. VMAT fronts for 10 and 6 MV beam energy were almost identical. HT fronts improved with different machine settings, but were still inferior to VMAT fronts.ConclusionsThat VMAT Pareto fronts are better than HT fronts may be explained by the fact that the linear accelerator can rapidly vary the dose rate. This is an advantage in simple geometries that might vanish in more complex geometries. Furthermore, one should be cautious when speaking about Pareto optimal plans as the best possible plans, as their calculation depends on many parameters.
引用
收藏
页码:3010 / 3019
页数:10
相关论文
共 50 条
  • [31] Comparison of Volumetric Modulated Arc Therapy (VMAT) with Serial Tomotherapy and Segmental (step and Shoot) IMRT for Boost Treatment of Prostate Cancer
    Wolff, D.
    Stieler, F.
    Polednik, M.
    Abo-Madyan, Y.
    Mai, S.
    Steil, V.
    Wenz, F.
    Lohr, F.
    MEDICAL PHYSICS, 2008, 35 (06) : 2847 - +
  • [32] Is IMAT the ultimate evolution of conformal radiotherapy? Dosimetric comparison of helical tomotherapy and volumetric modulated arc therapy for oropharyngeal cancer in a planning study
    Vernat, Stephanie Servagi
    Ali, David
    Puyraveau, Marc
    Viard, Romain
    Lisbona, Albert
    Fenoglietto, Pascal
    Bedos, Ludovic
    Makovicka, Libor
    Giraud, Philippe
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 280 - 285
  • [33] Dosimetric Comparison of Uniform Scanning Proton Therapy, Helical Tomotherapy, and Volumetric Modulated Arc Therapy in the Treatment of Bilateral Orbital Lymphoma
    Crew, J. B.
    James, J. A.
    Thornton, A. F.
    Gautam, A.
    Sullivan, M.
    Tasson, A.
    Wolanski, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S806 - S807
  • [34] Dosimetric comparison of tomotherapy and volumetric-modulated arc therapy for children with neuroblastoma
    Liu, Xia
    Liu, Zhikai
    Pang, Tingtian
    Dong, Tingting
    Qiu, Jie
    PEDIATRIC INVESTIGATION, 2020, 4 (03) : 186 - 191
  • [35] Dosimetric comparison of tomotherapy and volumetric-modulated arc therapy for children with neuroblastoma
    Liu Xia
    Liu Zhikai
    Pang Tingtian
    Dong Tingting
    Qiu Jie
    儿科学研究(英文), 2020, 04 (03) : 186 - 191
  • [36] Technical recommendations for implementation of Volumetric Modulated Arc Therapy and Helical Tomotherapy Total Body Irradiation
    Seravalli, Enrica
    Bosman, Mirjam E.
    Han, Chunhui
    Losert, Christoph
    Pazos, Montserrat
    Engstrom, Per E.
    Engellau, Jacob
    Fulcheri, Christian P. L.
    Zucchetti, Claudio
    Saldi, Simonetta
    Ferrer, Carlos
    Ocanto, Abrahams
    Hiniker, Susan M.
    Clark, Catharine H.
    Hussein, Mohammad
    Misson-Yates, Sarah
    Kobyzeva, Daria A.
    Loginova, Anna A.
    Hoeben, Bianca A. W.
    RADIOTHERAPY AND ONCOLOGY, 2024, 197
  • [37] Treatment Plan Comparison Generated by Volumetric Arc Modulation with Helical Tomotherapy and Conventional IMRT for Prostate Cancer Patients
    Tewatia, D.
    Tolakanahalli, R.
    Paliwal, B.
    Tome, W.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [38] Comparison of arc-modulated cone beam therapy and helical tomotherapy for three different types of cancer
    Ulrich, Silke
    Sterzing, Florian
    Nill, Simeon
    Schubert, Kai
    Herfarth, Klaus K.
    Debus, Juergen
    Oelfke, Uwe
    MEDICAL PHYSICS, 2009, 36 (10) : 4702 - 4710
  • [39] Dosimetric Comparisons of Intensity Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Helical Tomotherapy for Advanced Cervix Cancer with Simultaneous Integrated Boost
    Sommat, K.
    Hu, J.
    Swaminathan, T.
    Master, Z.
    Chua, L. M. H.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2016, 26 : 471 - 471
  • [40] Radiotherapy for Esophageal Cancer Using Simultaneous Integrated Boost Techniques: Dosimetric Comparison of Helical TomoTherapy, Volumetric-modulated Arc Therapy (RapidArc) and Dynamic Intensity-Modulated Radiotherapy
    Wang, Yao-Ching
    Chen, Shang-Wen
    Chien, Chun-Ru
    Hsieh, Te-Chun
    Yu, Chun-Yen
    Kuo, Yu-Cheng
    Yang, Shih-Neng
    Kao, Chia-Hung
    Liang, Ji-An
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (06) : 485 - 491