MR-based truncation and attenuation correction in integrated PET/MR hybrid imaging using HUGE with continuous table motion

被引:32
|
作者
Lindemann, Maike E. [1 ]
Oehmigen, Mark [1 ]
Blumhagen, Jan O. [2 ]
Gratz, Marcel [1 ,3 ]
Quick, Harald H. [1 ,3 ]
机构
[1] Univ Duisburg Essen, Univ Hosp Essen, High Field & Hybrid MR Imaging, Essen, Germany
[2] Siemens Healthcare GmbH, Magnet Resonance, Erlangen, Germany
[3] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
关键词
attenuation correction; continuous table motion; FOV extension; PET quantification; truncation correction; whole-body PET/MR; WHOLE-BODY PET/MR; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; QUANTITATIVE-EVALUATION; SYSTEMS; PHANTOM; CANCER;
D O I
10.1002/mp.12449
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The objective of this study was to introduce and evaluate a method for MR-based attenuation and truncation correction in phantom and patient measurements to improve PET quantification in PET/MR hybrid imaging. Methods: The fully MR-based method HUGE (B0 Homogenization using gradient enhancement) provides field-of-view extension in MR imaging, which can be used for truncation correction and improved PET quantification in PET/MR hybrid imaging. The HUGE method in this recent implementation is combined with continuously moving table data acquisition to provide a seamless nontruncated whole-body data set of the outer patient contours to complete the established standard MRbased Dixon-VIBE data for attenuation correction. The method was systematically evaluated in NEMA standard phantom experiments to investigate the impact of HUGE truncation correction on PET quantification. The method was then applied to 24 oncologic patients in whole-body PET/MR hybrid imaging. The impact of MR-based truncation correction with HUGE on PET data was compared to the impact of the established PET-based MLAA algorithm for contour detection. Results: In phantom and in all patient measurements, the standard Dixon-VIBE attenuation correction data show geometric distortions and signal truncations at the edges of the MR imaging field-ofview. In contrast, the Dixon-VIBE-based attenuation correction data additionally extended by applying HUGE shows significantly less distortion and truncations and due to the continuously moving table acquisition robustly provides smooth outer contours of the patient arms. In the investigated patient cases, MLAA frequently showed an overestimation of arm volume and associated artifacts limiting contour detection. When applying HUGE, an average relative increase in SUVmean in patients' lesion of 4.2% and for MLAA of 4.6% were measured, when compared to standard DixonVIBE only. In specific lesions maximal differences in SUVmean up to 13% for HUGE and 14% for MLAA were measured. Quantification in truncated regions showed maximal differences up to 40% for both, MLAA and HUGE. Average differences in those regions in SUVmean for HUGE are 13.3% and 14.6% for MLAA. In a patient with I-124 radiotracer PET-based MLAA contour detection completely failed in this specific case, whereas HUGE as MR-based approach provided accurate truncation correction. Conclusions: The HUGE method for truncation correction combined with continuous table movement extends the lateral MR field-of-view and effectively reduces truncations along the outer contours of the patient's arms in whole-body PET/MR imaging. HUGE as a fully MR-based approach is independent of the choice of radiotracer, thus also offering robust truncation correction in patients that are not injected with Fluordesoxyglucose (FDG) as radiotracer. Therefore, this method improves the standard Dixon MR-based attenuation correction and PET image quantification in whole-body PET/MR imaging applications. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:4559 / 4572
页数:14
相关论文
共 50 条
  • [41] The impact of MR-based attenuation correction in spinal cord FDG-PET/MR imaging for neurological studies
    Brancato, Valentina
    Borrelli, Pasquale
    Alfano, Vincenzo
    Picardi, Marco
    Mascalchi, Mario
    Nicolai, Emanuele
    Salvatore, Marco
    Aiello, Marco
    MEDICAL PHYSICS, 2021, 48 (10) : 5924 - 5934
  • [42] MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction
    Fei, Baowei
    Yang, Xiaofeng
    Nye, Jonathon A.
    Aarsvold, John N.
    Raghunath, Nivedita
    Cervo, Morgan
    Stark, Rebecca
    Meltzer, Carolyn C.
    Votaw, John R.
    MEDICAL PHYSICS, 2012, 39 (10) : 6443 - 6454
  • [43] MR-based attenuation correction in PET/MRI of the lungs: Clinical effect of truncation artifacts and ignoring bone
    Oen, S. K.
    Rausch, I.
    Lassen, M. L.
    Fenchel, M.
    Beyer, T.
    Eikenes, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S506 - S506
  • [44] Attenuation correction and truncation completion for breast PET/MR imaging using deep learning
    Li, Xue
    Johnson, Jacob M.
    Strigel, Roberta M.
    Bancroft, Leah C. Henze
    Hurley, Samuel A.
    Estakhraji, S. Iman Zare
    Kumar, Manoj
    Fowler, Amy M.
    McMillan, Alan B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04):
  • [45] Dynamic MR-based Respiratory Motion Compensation for Hybrid PET/MR System
    Miao, Shun
    Liao, Rui
    Moran, Gerald
    Butler, John
    Pan, Li
    Wang, Z. Jane
    PROCEEDINGS OF THE 2014 9TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2014, : 1915 - +
  • [46] MR-based attenuation correction in brain PET based on UTE sequences
    Jorge Cabello
    Stephan G Nekolla
    Sibylle I Ziegler
    EJNMMI Physics, 1 (Suppl 1)
  • [47] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Jan Vontobel
    Riccardo Liga
    Mathias Possner
    Olivier F. Clerc
    Fran Mikulicic
    Patrick Veit-Haibach
    Edwin E. G. W. ter Voert
    Tobias A. Fuchs
    Julia Stehli
    Aju P. Pazhenkottil
    Dominik C. Benz
    Christoph Gräni
    Oliver Gaemperli
    Bernhard Herzog
    Ronny R. Buechel
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1574 - 1580
  • [48] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Vontobel, Jan
    Liga, Riccardo
    Possner, Mathias
    Clerc, Olivier F.
    Mikulicic, Fran
    Veit-Haibach, Patrick
    ter Voert, Edwin E. G. W.
    Fuchs, Tobias A.
    Stehli, Julia
    Pazhenkottil, Aju P.
    Benz, Dominik C.
    Graeni, Christoph
    Gaemperli, Oliver
    Herzog, Bernhard
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (10) : 1574 - 1580
  • [49] Accuracy of a new atlas-based attenuation correction method in comparison to standard MR-based attenuation correction of the skull region in PET/MR imaging
    Rausch, I.
    Rischka, L.
    Ladefoged, C. N.
    Fenchel, M.
    Hahn, A.
    Lanzenberger, R.
    Traub-Weidinger, T.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S78 - S78
  • [50] Image artifacts from MR-based attenuation correction in dedicated PET/MR breast coil for PET/MR mammography
    Ihnho Cho
    Eunjung Kong
    Kyunga Chun
    EJNMMI Physics, 2 (Suppl 1)