Direct Comparison of Diagnostic Performance of 9 Quantitative Fecal Immunochemical Tests for Colorectal Cancer Screening

被引:93
|
作者
Gies, Anton [1 ,2 ]
Cuk, Katarina [3 ]
Schrotz-King, Petra [1 ,2 ]
Brenner, Hermann [1 ,2 ,3 ,4 ]
机构
[1] German Canc Res Ctr, Div Prevent Oncol, Heidelberg, Germany
[2] Natl Ctr Tumor Dis NCT, Heidelberg, Germany
[3] German Canc Res Ctr, Div Clin Epidemiol & Aging Res, Neuenheimer Feld 581, D-69120 Heidelberg, Germany
[4] German Canc Res Ctr, German Canc Consortium DKTK, Heidelberg, Germany
关键词
Fecal Occult Blood Test; Colon Cancer; Advanced Adenoma; Early Detection; OCCULT BLOOD-TEST; HEMOGLOBIN; NEOPLASIA; COLONOSCOPY; ADENOMAS;
D O I
10.1053/j.gastro.2017.09.018
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND & AIMS: A variety of fecal immunochemical tests (FITs) for hemoglobin (Hb) are used in colorectal cancer screening. It is unclear to what extent differences in reported sensitivities and specificities reflect true heterogeneity in test performance or differences in study populations or varying pre-analytical conditions. We directly compared the sensitivity and specificity values with which 9 quantitative (laboratory-based and point-of-care) FITs detected advanced neoplasms (AN) in a single colorectal cancer screening study. METHODS: Pre-colonoscopy stool samples were obtained from participants of screening colonoscopy in Germany from 2005 through 2010 and frozen at -80 degrees C until analysis. The stool samples were thawed, homogenized, and used for 9 different quantitative FITs in parallel. Colonoscopy and histology reports were collected from all participants and evaluated by 2 independent, trained research assistants who were blinded to the test results. Comparative evaluations of diagnostic performance for AN were made at preset manufacturers' thresholds (range, 2.0-17.0 mu g Hb/g feces), at a uniform threshold (15 mu g Hb/g feces), and at adjusted thresholds yielding defined levels of specificity (99%, 97%, and 93%). RESULTS: Of the 1667 participants who fulfilled the inclusion criteria, all cases with AN (n = 216) and 300 randomly selected individuals without AN were included in the analysis. Sensitivities and specificities for AN varied widely when we used the preset thresholds (21.8%-46.3% and 85.7%-97.7%, respectively) or the uniform threshold (16.2%-34.3% and 94.0%-98.0%, respectively). Adjusting thresholds to yield a specificity of 99%, 97%, or 93% resulted in almost equal sensitivities for detection of AN 14.4%-18.5%, 21.3%-23.6%, and 30.1%-35.2%, respectively) and almost equal positivity rates (2.8%-3.4%, 5.8%-6.1%, and 10.1%-10.9%, respectively). CONCLUSIONS: Apparent heterogeneity in diagnostic performance of quantitative FITs can be overcome to a large extent by adjusting thresholds to yield defined levels of specificity or positivity rates. Rather than simply using thresholds recommended by the manufacturer, screening programs should choose thresholds based on intended levels of specificity and manageable positivity rates.
引用
收藏
页码:93 / 104
页数:12
相关论文
共 50 条
  • [41] Colorectal cancer screening with fecal immunochemical testing or primary colonoscopy: inequities in diagnostic yield
    Bonander, Carl
    Westerberg, Marcus
    Chauca Strand, Gabriella
    Forsberg, Anna
    Stroemberg, Ulf
    JNCI CANCER SPECTRUM, 2024, 8 (03)
  • [42] Comparison of Performance of Two Stool DNA Tests and a Fecal Immunochemical Test in Detecting Colorectal Neoplasm: A Multicenter Diagnostic Study
    Jin, Peng
    You, Peng
    Fang, Jingyuan
    Kang, Qian
    Gu, Fang
    Cai, Yunlong
    Zhai, Huihong
    Wang, Bangmao
    Li, Yanqing
    Xu, Junfeng
    Wang, Jiheng
    He, Yuqi
    Wang, Yang
    Dai, Min
    Sheng, Jianqiu
    CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2022, 31 (03) : 654 - 661
  • [43] An Exploratory Analysis of Fecal Immunochemical Test Performance for Colorectal Cancer Screening in Nigeria
    Gregory C. Knapp
    Avinash Sharma
    Bolatito Olopade
    Olusegun I. Alatise
    Olalekan Olasehinde
    Olujide O. Arije
    Philip E. Castle
    T. Peter Kingham
    World Journal of Surgery, 2019, 43 : 2674 - 2680
  • [44] An Exploratory Analysis of Fecal Immunochemical Test Performance for Colorectal Cancer Screening in Nigeria
    Knapp, Gregory C.
    Sharma, Avinash
    Olopade, Bolatito
    Alatise, Olusegun, I
    Olasehinde, Olalekan
    Arije, Olujide O.
    Castle, Philip E.
    Kingham, T. Peter
    WORLD JOURNAL OF SURGERY, 2019, 43 (11) : 2674 - 2680
  • [45] Colorectal Cancer Screening: Fecal immunochemical Test or Sigmoidoscopy?
    Hofmann-Assmus, Marion
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2021, 59 (07): : 626 - 628
  • [46] Diagnostic inconsistency of faecal immunochemical tests for haemoglobin in population screening of colorectal cancer
    Huang, Yanqin
    Ge, Weiting
    London, Viktoriya
    Li, Qilong
    Cai, Shanrong
    Zhang, Suzhan
    Zheng, Shu
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (11) : 2173 - 2180
  • [47] Making the best use of quantitative fecal immunochemical test results in colorectal cancer screening
    Brenner, Hermann
    Hoffmeister, Michael
    JOURNAL OF INTERNAL MEDICINE, 2024, 296 (02) : 118 - 120
  • [48] Optimizing Fecal Immunochemical Testing For Colorectal Cancer Screening
    Schreuders, Eline H.
    Wieten, Els
    Kuipers, Ernst J.
    Spaander, Manon C. W.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2017, 15 (10) : 1498 - 1499
  • [49] Colorectal cancer screening with fecal immunochemical testing in Nigeria
    Chido-Amajuoyi, Onyema Greg
    LANCET GLOBAL HEALTH, 2022, 10 (11): : E1561 - E1561
  • [50] Performance characteristics & comparison of two immunochemical & two guaiac fecal occult blood screening tests for colorectal neoplasia.
    Rozen, P
    Knaani, J
    Samuel, Z
    GASTROENTEROLOGY, 1997, 112 (04) : A647 - A647