Diagnostic inconsistency of faecal immunochemical tests for haemoglobin in population screening of colorectal cancer

被引:6
|
作者
Huang, Yanqin [1 ,2 ]
Ge, Weiting [1 ,2 ]
London, Viktoriya [3 ]
Li, Qilong [4 ]
Cai, Shanrong [1 ,2 ]
Zhang, Suzhan [1 ,2 ]
Zheng, Shu [1 ,2 ]
机构
[1] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Canc Inst,Key Lab Canc Prevent & Intervent,China, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Key Lab Mol Biol Med Sci, Hangzhou, Zhejiang, Peoples R China
[3] Case Western Reserve Sch Med, Cleveland, OH USA
[4] Jiashan Inst Canc Prevent & Treatment, Hangzhou, Zhejiang, Peoples R China
关键词
colorectal cancer screening; faecal immunochemical test; haemoglobin; quality assurance; OCCULT-BLOOD-TESTS; COST-EFFECTIVENESS ANALYSIS; CUTOFF LEVELS; PERFORMANCE; NEOPLASMS; TRIAL;
D O I
10.1515/cclm-2013-0232
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: There is currently very little data available on the consistency of quantitative and qualitative faecal immunochemical test (FIT) for colorectal cancer screening. Methods: A representative random population (n = 1889, 40-74 year olds) in Jiashan, China was invited for FIT screening in 2012. Faecal samples were collected by a single specimen collection device and simultaneously tested by a quantitative FIT (OC-SENSOR, OC) and two qualitative FITs (FIT A and FIT B with intrinsic positive haemoglobin cut-off concentrations of 20 mu g Hb/g faeces and 40 mu g Hb/g faeces, respectively). The observational criteria for a positive result of the qualitative FIT were set according to the density of the colour appearing in the test strip. The results produced by the quantitative and qualitative FIT for each sample were compared.. coefficient was used to measure consistency. Results: A total of 1368 (72.4%) individuals returned faecal samples. Both FIT A and FIT B precisely identified all faecal samples with haemoglobin concentration above 100 mu g Hb/g faeces, but the overall consistency was poor for OC & FIT A (kappa = 0.32, 95% CI 0.20-0.44) and was moderate for OC & FIT B (kappa = 0.74, 95% CI 0.64-0.85). A more favourable consistency (kappa = 0.64, 95% CI 0.57-0.72) was achieved when a different positive criterion was employed for FIT A. Conclusions: The diagnostic inconsistency between quantitative and qualitative FITs mainly exists in the faecal samples with low haemoglobin concentrations. Refining the criterion for a positive result may be a feasible way to improve the accuracy of qualitative FIT.
引用
收藏
页码:2173 / 2180
页数:8
相关论文
共 50 条
  • [1] Making colorectal cancer screening FITTER for purpose with quantitative faecal immunochemical tests for haemoglobin (FIT)
    Fraser, Callum G.
    Halloran, Stephen P.
    Allison, James E.
    Young, Graeme P.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (11) : 2065 - 2067
  • [2] Comparison of quantitative faecal immunochemical tests for haemoglobin (FIT) for asymptomatic population screening
    Fraser, Callum G.
    TRANSLATIONAL CANCER RESEARCH, 2016, 5 : S916 - S919
  • [3] Faecal immunochemical tests: A valuable tool for colorectal cancer screening
    Lepage, Come
    Hamza, Samia
    DIGESTIVE AND LIVER DISEASE, 2012, 44 (08) : 629 - 630
  • [4] Screening for colorectal cancer with immunochemical faecal occult blood tests
    Faivre, Jean
    Dancourt, Vincent
    Lejeune, Catherine
    DIGESTIVE AND LIVER DISEASE, 2012, 44 (12) : 967 - 973
  • [5] Diagnostic accuracy of immunochemical versus guaiac faecal occult blood tests for colorectal cancer screening
    Adolfo Parra-Blanco
    Antonio Z. Gimeno-García
    Enrique Quintero
    David Nicolás
    Santiago G. Moreno
    Alejandro Jiménez
    Manuel Hernández-Guerra
    Marta Carrillo-Palau
    Yoshinobu Eishi
    Julio López-Bastida
    Journal of Gastroenterology, 2010, 45 : 703 - 712
  • [6] Diagnostic accuracy of immunochemical versus guaiac faecal occult blood tests for colorectal cancer screening
    Parra-Blanco, Adolfo
    Gimeno-Garcia, Antonio Z.
    Quintero, Enrique
    Nicolas, David
    Moreno, Santiago G.
    Jimenez, Alejandro
    Hernandez-Guerra, Manuel
    Carrillo-Palau, Marta
    Eishi, Yoshinobu
    Lopez-Bastida, Julio
    JOURNAL OF GASTROENTEROLOGY, 2010, 45 (07) : 703 - 712
  • [7] A randomised comparison of two faecal immunochemical tests in population-based colorectal cancer screening
    Grobbee, E. J.
    van der Vlugt, M.
    van Vuuren, A. J.
    Stroobants, A. K.
    Mundt, M. W.
    Spijker, W. J.
    Bongers, E. J. C.
    Kuipers, E. J.
    Lansdorp-Vogelaar, I.
    Bossuyt, P. M.
    Dekker, E.
    Spaander, M. C. W.
    GUT, 2017, 66 (11) : 1975 - 1982
  • [8] Impact of a new sampling buffer on faecal haemoglobin stability in a colorectal cancer screening programme by the faecal immunochemical test
    Grazzini, Grazia
    Ventura, Leonardo
    Rubeca, Tiziana
    Rapi, Stefano
    Cellai, Filippo
    Di Dia, Pietro P.
    Mallardi, Beatrice
    Mantellini, Paola
    Zappa, Marco
    Castiglione, Guido
    EUROPEAN JOURNAL OF CANCER PREVENTION, 2017, 26 (04) : 285 - 291
  • [9] Screening for colorectal cancer by faecal occult blood test: comparison of immunochemical tests
    Castiglione, G
    Zappa, M
    Grazzini, G
    Rubeca, T
    Turco, P
    Sani, C
    Ciatto, S
    JOURNAL OF MEDICAL SCREENING, 2000, 7 (01) : 35 - 37
  • [10] Systematic review and meta-analysis : diagnostic accuracy of faecal immunochemical testing for haemoglobin (FIT) in detecting colorectal cancer for both symptomatic and screening population
    Stonestreet, J.
    Chandrapalan, S.
    Woolley, D.
    Uthman, O.
    Arasaradnam, R. P.
    ACTA GASTRO-ENTEROLOGICA BELGICA, 2019, 82 (02) : 291 - 299