Diagnostic inconsistency of faecal immunochemical tests for haemoglobin in population screening of colorectal cancer

被引:6
|
作者
Huang, Yanqin [1 ,2 ]
Ge, Weiting [1 ,2 ]
London, Viktoriya [3 ]
Li, Qilong [4 ]
Cai, Shanrong [1 ,2 ]
Zhang, Suzhan [1 ,2 ]
Zheng, Shu [1 ,2 ]
机构
[1] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Canc Inst,Key Lab Canc Prevent & Intervent,China, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Key Lab Mol Biol Med Sci, Hangzhou, Zhejiang, Peoples R China
[3] Case Western Reserve Sch Med, Cleveland, OH USA
[4] Jiashan Inst Canc Prevent & Treatment, Hangzhou, Zhejiang, Peoples R China
关键词
colorectal cancer screening; faecal immunochemical test; haemoglobin; quality assurance; OCCULT-BLOOD-TESTS; COST-EFFECTIVENESS ANALYSIS; CUTOFF LEVELS; PERFORMANCE; NEOPLASMS; TRIAL;
D O I
10.1515/cclm-2013-0232
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: There is currently very little data available on the consistency of quantitative and qualitative faecal immunochemical test (FIT) for colorectal cancer screening. Methods: A representative random population (n = 1889, 40-74 year olds) in Jiashan, China was invited for FIT screening in 2012. Faecal samples were collected by a single specimen collection device and simultaneously tested by a quantitative FIT (OC-SENSOR, OC) and two qualitative FITs (FIT A and FIT B with intrinsic positive haemoglobin cut-off concentrations of 20 mu g Hb/g faeces and 40 mu g Hb/g faeces, respectively). The observational criteria for a positive result of the qualitative FIT were set according to the density of the colour appearing in the test strip. The results produced by the quantitative and qualitative FIT for each sample were compared.. coefficient was used to measure consistency. Results: A total of 1368 (72.4%) individuals returned faecal samples. Both FIT A and FIT B precisely identified all faecal samples with haemoglobin concentration above 100 mu g Hb/g faeces, but the overall consistency was poor for OC & FIT A (kappa = 0.32, 95% CI 0.20-0.44) and was moderate for OC & FIT B (kappa = 0.74, 95% CI 0.64-0.85). A more favourable consistency (kappa = 0.64, 95% CI 0.57-0.72) was achieved when a different positive criterion was employed for FIT A. Conclusions: The diagnostic inconsistency between quantitative and qualitative FITs mainly exists in the faecal samples with low haemoglobin concentrations. Refining the criterion for a positive result may be a feasible way to improve the accuracy of qualitative FIT.
引用
收藏
页码:2173 / 2180
页数:8
相关论文
共 50 条
  • [41] Faecal immunochemical tests for haemoglobin: Analytical challenges and potential solutions
    Benton, Sally C.
    Symonds, Erin
    Djedovic, Natasha
    Jones, Samantha
    Deprez, Liesbet
    Kocna, Petr
    Auge, Josep Maria
    CLINICA CHIMICA ACTA, 2021, 517 : 60 - 65
  • [42] Effect of delay in sampling on haemoglobin determined by faecal immunochemical tests
    Brown, Louise F.
    Fraser, Callum G.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 : 604 - 605
  • [43] Faecal immunochemical tests versus guaiac faecal occult blood tests: what clinicians and colorectal cancer screening programme organisers need to know
    Tinmouth, Jill
    Lansdorp-Vogelaar, Iris
    Allison, James E.
    GUT, 2015, 64 (08) : 1327 - U204
  • [44] Guaiac-based faecal occult blood tests versus faecal immunochemical tests for colorectal cancer screening in average-risk individuals
    Grobbee, Esmee J.
    Ha Wisse, Pieter
    Schreuders, Eline H.
    van Roon, Aafke
    van Dam, Leonie
    Zauber, Ann G.
    Lansdorp-Vogelaar, Iris
    Bramer, Wichor
    Berhane, Sarah
    Deeks, Jonathan J.
    Steyerberg, Ewout W.
    van Leerdam, Monique E.
    Spaander, Manon Cw
    Kuipers, Ernst J.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2022, (06):
  • [45] Different seasons with decreased performance of immunochemical faecal occult blood tests in colorectal cancer screening Response
    Grazzini, Grazia
    Zappa, Marco
    Ventura, Leonardo
    Rubeca, Tiziana
    Halloran, Stephen P.
    GUT, 2011, 60 (09) : 1304 - 1304
  • [46] A standard for Faecal Immunochemical TesTs for Haemoglobin Evaluation Reporting (FITTER)
    Fraser, Callum G.
    Allison, James E.
    Young, Graeme P.
    Halloran, Stephen P.
    Seaman, Helen
    ANNALS OF CLINICAL BIOCHEMISTRY, 2014, 51 (02) : 301 - 302
  • [47] Guaiac versus immunochemical tests: faecal occult blood test screening for colorectal cancer in a rural community
    Hughes, K
    Leggett, B
    Del Mar, C
    Croese, J
    Fairley, S
    Masson, J
    Aitken, J
    Clavarino, A
    Janda, M
    Stanton, WR
    Tong, SL
    Newman, B
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF PUBLIC HEALTH, 2005, 29 (04) : 358 - 364
  • [48] Cost-effectiveness analysis of colorectal cancer screening by immunochemical or biochemical faecal occult blood tests
    Aguiar, R
    Gimeno, A
    Parra-Blanco, A
    Nicolas, D
    Deniz, D
    Garcia, M
    Hernandez, A
    Leon, F
    Serrano, P
    Eishi, Y
    Sano, Y
    Quintero, E
    GASTROENTEROLOGY, 2004, 126 (04) : A344 - A344
  • [49] A Systematic Review on Diagnostic Test Accuracy of Fecal Immunochemical Tests for Colorectal Cancer Screening
    van Roon, Aafke H.
    van Dam, Leonie
    Arends, Lidia R.
    Zauber, Ann G.
    Young, Graeme P.
    van Ballegooijen, Marjolein
    Habbema, Dik F.
    van Leerdam, Monique E.
    Steyerberg, Ewout W.
    Kuipers, Ernst J.
    GASTROENTEROLOGY, 2014, 146 (05) : S409 - S410
  • [50] Comparative evaluation of nine faecal immunochemical tests for the detection of colorectal cancer
    Tao, Sha
    Seiler, Christoph M.
    Ronellenfitsch, Ulrich
    Brenner, Hermann
    ACTA ONCOLOGICA, 2013, 52 (08) : 1667 - 1675