Diagnostic inconsistency of faecal immunochemical tests for haemoglobin in population screening of colorectal cancer

被引:6
|
作者
Huang, Yanqin [1 ,2 ]
Ge, Weiting [1 ,2 ]
London, Viktoriya [3 ]
Li, Qilong [4 ]
Cai, Shanrong [1 ,2 ]
Zhang, Suzhan [1 ,2 ]
Zheng, Shu [1 ,2 ]
机构
[1] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Canc Inst,Key Lab Canc Prevent & Intervent,China, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Key Lab Mol Biol Med Sci, Hangzhou, Zhejiang, Peoples R China
[3] Case Western Reserve Sch Med, Cleveland, OH USA
[4] Jiashan Inst Canc Prevent & Treatment, Hangzhou, Zhejiang, Peoples R China
关键词
colorectal cancer screening; faecal immunochemical test; haemoglobin; quality assurance; OCCULT-BLOOD-TESTS; COST-EFFECTIVENESS ANALYSIS; CUTOFF LEVELS; PERFORMANCE; NEOPLASMS; TRIAL;
D O I
10.1515/cclm-2013-0232
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: There is currently very little data available on the consistency of quantitative and qualitative faecal immunochemical test (FIT) for colorectal cancer screening. Methods: A representative random population (n = 1889, 40-74 year olds) in Jiashan, China was invited for FIT screening in 2012. Faecal samples were collected by a single specimen collection device and simultaneously tested by a quantitative FIT (OC-SENSOR, OC) and two qualitative FITs (FIT A and FIT B with intrinsic positive haemoglobin cut-off concentrations of 20 mu g Hb/g faeces and 40 mu g Hb/g faeces, respectively). The observational criteria for a positive result of the qualitative FIT were set according to the density of the colour appearing in the test strip. The results produced by the quantitative and qualitative FIT for each sample were compared.. coefficient was used to measure consistency. Results: A total of 1368 (72.4%) individuals returned faecal samples. Both FIT A and FIT B precisely identified all faecal samples with haemoglobin concentration above 100 mu g Hb/g faeces, but the overall consistency was poor for OC & FIT A (kappa = 0.32, 95% CI 0.20-0.44) and was moderate for OC & FIT B (kappa = 0.74, 95% CI 0.64-0.85). A more favourable consistency (kappa = 0.64, 95% CI 0.57-0.72) was achieved when a different positive criterion was employed for FIT A. Conclusions: The diagnostic inconsistency between quantitative and qualitative FITs mainly exists in the faecal samples with low haemoglobin concentrations. Refining the criterion for a positive result may be a feasible way to improve the accuracy of qualitative FIT.
引用
收藏
页码:2173 / 2180
页数:8
相关论文
共 50 条
  • [31] A comparative effectiveness trial of two faecal immunochemical tests for haemoglobin (FIT). Assessment of test performance and adherence in a single round of a population-based screening programme for colorectal cancer
    Passamonti, Basilio
    Malaspina, Morena
    Fraser, Callum G.
    Tintori, Beatrice
    Carlani, Angela
    D'Angelo, Valentina
    Galeazzi, Paola
    Di Dato, Eugenio
    Mariotti, Loretta
    Bulletti, Simonetta
    D'Amico, Maria Rosaria
    Gustinucci, Daniela
    Martinelli, Nadia
    Spita, Nicoletta
    Cesarini, Elena
    Rubeca, Tiziana
    Giaimo, Mariadonata
    Segnan, Nereo
    Senore, Carlo
    GUT, 2018, 67 (03) : 485 - 496
  • [32] Prospective cohort study of compliance with faecal immunochemical tests for colorectal cancer screening in Hong Kong
    Wong, Martin C. S.
    Ching, Jessica Y. L.
    Lam, Thomas Y. T.
    Luk, Arthur K. C.
    Hirai, Hoyee W.
    Griffiths, Sian M.
    Chan, Francis K. L.
    Sung, Joseph J. Y.
    PREVENTIVE MEDICINE, 2013, 57 (03) : 227 - 231
  • [33] Comparison between a guaiac and three immunochemical faecal occult blood tests in screening for colorectal cancer
    Faivre, J.
    Dancourt, V.
    Denis, B.
    Dorval, E.
    Piette, C.
    Perrin, Ph
    Bidan, J. M.
    Jard, C.
    Jung, S.
    Levillain, R.
    Viguier, J.
    Bretagne, J. F.
    EUROPEAN JOURNAL OF CANCER, 2012, 48 (16) : 2969 - 2976
  • [34] Fecal Immunochemical Tests for Colorectal Cancer Screening
    Daly, Jeanette
    AMERICAN JOURNAL OF NURSING, 2012, 112 (10) : 67 - 69
  • [35] Colorectal cancer screening with faecal immunochemical test: Patterns of participation
    Heyman, Hanna
    Blom, Johannes
    Saraste, Deborah
    JOURNAL OF MEDICAL SCREENING, 2024, 31 (01) : 15 - 20
  • [36] Faecal haemoglobin concentrations by gender and age: implications for population-based screening for colorectal cancer
    McDonald, Paula J.
    Strachan, Judith A.
    Digby, Jayne
    Steele, Robert J. C.
    Fraser, Callum G.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (05) : 935 - 940
  • [37] a Cost-Effectiveness Analysis in Colorectal Cancer Screening Comparing Immunochemical Faecal Occult Blood Tests with Guaiac Faecal Occult Blood Tests and No Screening.
    van Rossum, Leo G.
    van Rijn, Anne Floortje
    Verbeek, Andre L.
    van Oijen, Martijn G.
    Laheij, Robert J.
    Fockens, Paul
    Jansen, Jan B.
    Adang, Eddy M.
    Dekker, Evelien
    GASTROENTEROLOGY, 2009, 136 (05) : A331 - A331
  • [38] Detection capability of quantitative faecal immunochemical tests for haemoglobin (FIT) and reporting of low faecal haemoglobin concentrations
    Fraser, Callum G.
    Benton, Sally C.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (05) : 611 - 616
  • [39] The Fas Track F T study: diagnostic accuracy of faecal immunochemical test for haemoglobin in patients with suspected colorectal cancer
    Turvill, James L.
    Turnock, Daniel
    Cottingham, Dan
    Haritakis, Monica
    Jeffery, Laura
    Girdwood, Annabelle
    Hearfield, Tom
    Mitchell, Alex
    Keding, Ada
    BRITISH JOURNAL OF GENERAL PRACTICE, 2021, 71 (709): : E643 - E651
  • [40] An assessment of the effect of haemoglobin variants on detection by faecal immunochemical tests
    Carroll, Magdalen R. R.
    John, Cerin
    Mantio, Debbie
    Djedovic, Natasha K.
    Benton, Sally C.