A new microfluidic device for separating circulating tumor cells based on their physical properties by using electrophoresis and dielectrophoresis forces within an electrical field

被引:19
|
作者
Dabighi, Ali [1 ]
Toghraie, Davood [1 ]
机构
[1] Islamic Azad Univ, Khomeinishahr Branch, Dept Mech Engn, Khomeinishahr 84175119, Iran
关键词
Microfluidic device; Impedance; Numerical simulation; Blood; LID-DRIVEN CAVITY; HEAT-TRANSFER; TURBULENT-FLOW; WATER/AL2O3; NANOFLUID; PARTICLE SEPARATION; ENTROPY GENERATION; MIXED CONVECTION; LIQUID-VAPOR; TWISTED-TAPE; NANOPARTICLES;
D O I
10.1016/j.cmpb.2019.105147
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: The presence of circulating tumor cells in the patient's blood is a clinical factor that indicates the initiation of metastasis. Methods: In this paper, a microfluidic device is designed to separate, enumerate, and to diagnose cancer cells from the patient's blood sample. Here, we present a new microfluidic device that is capable of separating circulating tumor cells based on their physical properties by using electrophoresis and dielectrophoresis forces within an electrical field. Cells are modeled as spherical particles, each size as a representor of different cells. Results: The distance between cells has been increased, and by using a novel method of rolling up the convergent and divergent channels, the primary distance of elements, which was 50 mu m, reached 142-178.5. Cells with different diameters sense a different force, and therefore, cancer cells can be separating from other cells in the blood, such as white blood cells. To make the current device, practical for clinical studies, a cell enumerator is designed for downstream of cell separator. In the cell enumerator, a change in impedance occurs when a cell passes through the sensor. Conclusions: By measuring the electrical current between two electrodes of the cell enumerator sensor, the exact count of cells can be obtained. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] Continuous Separation of Circulating Tumor Cells from Whole Blood Using a Slanted Weir Microfluidic Device
    Yoon, Yousang
    Lee, Jusin
    Ra, Moonsoo
    Gwon, Hyeokshin
    Lee, Seungwon
    Kim, Min Young
    Yoo, Ki-Chun
    Sul, Onejae
    Kim, Chul Geun
    Kim, Whoi-Yul
    Park, Jea-Gun
    Lee, Su-Jae
    Lee, Young Yiul
    Choi, Ho Soon
    Lee, Seung-Beck
    CANCERS, 2019, 11 (02):
  • [22] Highly Efficient Isolation of Circulating Tumor Cells Using a Simple Wedge-Shaped Microfluidic Device
    Qin, Luman
    Zhou, Wei
    Zhang, Shoukun
    Cheng, Boran
    Wang, Shubin
    Li, Songzhan
    Yang, Yanqin
    Wang, Shengxiang
    Liu, Kan
    Zhang, Nangang
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (06) : 1536 - 1541
  • [23] Expansion and characterization on ALK positive NSCLC circulating tumor cells isolated using a size based inertial microfluidic Labyrinth device
    Chen, Yuru
    Fouladdel, Shamileh
    Ball, Harrison
    Cheng, Xu
    Bao, Liwei
    Serhan, Habib
    Liu, Albert
    Vandenburg, Bryce
    Goo, Laura
    Merrill, Nathan
    Udager, Aaron
    Qin, Angel
    Merajver, Sofia D.
    Nagrath, Sunitha
    CANCER RESEARCH, 2023, 83 (07)
  • [24] Design and Application of Microfluidic Capture Device for Physical-Magnetic Isolation of MCF-7 Circulating Tumor Cells
    Bendre, Akhilesh
    Somasekhara, Derangula
    Nadumane, Varalakshmi K.
    Sriram, Ganesan
    Bilimagga, Ramesh S.
    Kurkuri, Mahaveer D.
    BIOSENSORS-BASEL, 2024, 14 (06):
  • [25] Microfluidic detection of circulating tumor cells (CTC) using size filtration based capture
    Lee, Sung-Woo
    Jung, Hyo-Il
    Kang, Ji-Yoon
    6TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE AND ENGINEERING (IEEE-NANOMED 2012), 2012,
  • [26] Detection of sarcoma circulating tumor cells using a size based microfiltration device
    Hayashi, Masanori
    Zhu, Peixuan
    Albert, Catherine M.
    Steppan, Diana
    McCarty, Gregory
    Jackson, Kyle W.
    Tang, Cha-Mei
    Loeb, David M.
    CANCER RESEARCH, 2016, 76
  • [27] Simulation and analysis of geometric parameters based on Taguchi method in Y-Y microfluidic device for circulating tumor cell separation by alternating current dielectrophoresis
    Lv, Binghui
    Cai, Jun
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1693
  • [28] Visual Quantitative Detection of Circulating Tumor Cells with Single-Cell Sensitivity Using a Portable Microfluidic Device
    Abate, Mahlet Fasil
    Jia, Shasha
    Ahmed, Metages Gashaw
    Li, Xingrui
    Lin, Li
    Chen, Xiaoqian
    Zhu, Zhi
    Yang, Chaoyong
    SMALL, 2019, 15 (14)
  • [29] Rapid Isolation of Circulating Tumor Cells from Glioblastoma Patients Using a Lateral Filter Array Microfluidic Device
    Gavioli, Victoria D'Amario
    Filho, Marcos Vilas Boas
    Castro, Gustavo R.
    Filho, Pedro Tadao Hamamoto
    Ferrasi, Adriana Camargo
    Pedrosa, Valber A.
    CHEMOSENSORS, 2025, 13 (02)
  • [30] Radial flow microfluidic device for high-throughput affinity-based isolation of circulating tumor cells
    Murlidhar, Vasudha
    Reddy, Rishindra M.
    Zeinali, Mina
    Grabauskiene, Svetlana
    Ghannad-Rezaie, Mostafa
    Wicha, Max S.
    Simeone, Diane M.
    Ramnath, Nithya
    Nagrath, Sunitha
    CANCER RESEARCH, 2014, 74 (19)