Design and Application of Microfluidic Capture Device for Physical-Magnetic Isolation of MCF-7 Circulating Tumor Cells

被引:2
|
作者
Bendre, Akhilesh [1 ]
Somasekhara, Derangula [2 ]
Nadumane, Varalakshmi K. [2 ]
Sriram, Ganesan [3 ]
Bilimagga, Ramesh S. [4 ]
Kurkuri, Mahaveer D. [1 ,5 ]
机构
[1] JAIN Deemed To Be Univ, Ctr Res Funct Mat, Bengaluru 562112, Karnataka, India
[2] JAIN Deemed To Be Univ, Sch Sci, Dept Biotechnol, JC Rd 34,1st Cross Rd, Bengaluru 560027, Karnataka, India
[3] Yeungnam Univ, Sch Chem Engn, Gyongsan 38541, South Korea
[4] Fortis Hosp, Dept Minimal Access GI & Bariatr Surg, 14 Cunningham Rd, Bengaluru 560052, Karnataka, India
[5] JAIN Deemed To Be Univ, Interdisciplinary Res Ctr IDRC, Jain Global Campus, Bengaluru 562112, Karnataka, India
来源
BIOSENSORS-BASEL | 2024年 / 14卷 / 06期
关键词
microfluidics; CTCs; capture; physical-bio affinity based/guided magnetic isolation; functionalized nanoparticles; simulation-aided; NANOPARTICLES; FUTURE;
D O I
10.3390/bios14060308
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Circulating tumor cells (CTCs) are a type of cancer cell that spreads from the main tumor to the bloodstream, and they are often the most important among the various entities that can be isolated from the blood. For the diagnosis of cancer, conventional biopsies are often invasive and unreliable, whereas a liquid biopsy, which isolates the affected item from blood or lymph fluid, is a less invasive and effective diagnostic technique. Microfluidic technologies offer a suitable channel for conducting liquid biopsies, and this technology is utilized to extract CTCs in a microfluidic chip by physical and bio-affinity-based techniques. This effort uses functionalized magnetic nanoparticles (MNPs) in a unique microfluidic chip to collect CTCs using a hybrid (physical and bio-affinity-based/guided magnetic) capturing approach with a high capture rate. Accordingly, folic acid-functionalized Fe3O4 nanoparticles have been used to capture MCF-7 (breast cancer) CTCs with capture efficiencies reaching up to 95% at a 10 mu L/min flow rate. Moreover, studies have been conducted to support this claim, including simulation and biomimetic investigations.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Design and production of a novel microfluidic device for the capture and isolation of circulating tumor cell clusters
    Shaner, Sebastian W.
    Allen, Jeffrey K.
    Felderman, Martina
    Pasko, Evan T.
    Wimer, Carina D.
    Cosford, Nicholas D. P.
    Kassegne, Samuel
    Teriete, Peter
    AIP ADVANCES, 2019, 9 (06)
  • [2] Chemical modification of silicon nitride microsieves for capture of MCF-7 circulating tumor cells of breast cancer
    Thien Dien To
    Huyen Thoai Le
    Mai Ngoc Thi Dinh
    Anh Tuan Nguyen
    Tin Chanh Duc Doan
    Chien Mau Dang
    ADVANCES IN NATURAL SCIENCES-NANOSCIENCE AND NANOTECHNOLOGY, 2015, 6 (02)
  • [3] Design and Clinical Application of an Integrated Microfluidic Device for Circulating Tumor Cells Isolation and Single-Cell Analysis
    Xu, Mingxin
    Liu, Wenwen
    Zou, Kun
    Wei, Song
    Zhang, Xinri
    Li, Encheng
    Wang, Qi
    MICROMACHINES, 2021, 12 (01)
  • [4] Efficient capture of circulating tumor cells with a novel immunocytochemical microfluidic device
    Dickson, Mary Nora
    Tsinberg, Pavel
    Tang, Zhongliang
    Bischoff, Farideh Z.
    Wilson, Timothy
    Leonard, Edward F.
    BIOMICROFLUIDICS, 2011, 5 (03):
  • [5] Design of a microfluidic device for immunoaffinity-based isolation of circulating tumor cells with minimal clogging
    Sen-Dogan, Begum
    Yildirim, Ender
    Sahin, Sebnem
    Ozgur, Ebru
    Zorlu, Ozge
    Kulah, Haluk
    SENSORS AND ACTUATORS REPORTS, 2023, 6
  • [6] Microfluidic Continuous Modification of Magnetic Nanoparticles for Circulating Tumor Cell Capture and Isolation
    Zhang, Changqing
    Lin, Jianwei
    Yu, Yunru
    Deng, Dawei
    Yu, Ying
    Zhang, Dagan
    Zhong, Qifeng
    ADVANCED MATERIALS TECHNOLOGIES, 2023, 8 (15)
  • [7] Isolation of circulating tumour cells by physical means in a microfluidic device: a review
    Patil, Pravin
    Madhuprasad
    Kumeria, Tushar
    Losic, Dusan
    Kurkuri, Mahaveer
    RSC ADVANCES, 2015, 5 (109): : 89745 - 89762
  • [8] Entrapment of microparticles in a microfluidic device: a model for isolation of circulating tumor cells
    Szelig, Adam Gyorgy
    Kurdi, Csilla
    Hartdegen, Marton
    Ivan, Kristof
    Koszegi, Tamas
    Lakil, Andras Jozsef
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [9] Aptamer-based Microfluidic Device for Isolation of Circulating Tumor Cells
    Lukyanenko, Kirill A.
    Koshmanova, Anastasia A.
    Shesternya, Pavel A.
    Kichkailo, Anna S.
    JOURNAL OF SIBERIAN FEDERAL UNIVERSITY-MATHEMATICS & PHYSICS, 2024, 17 (06): : 743 - 753
  • [10] Microfluidic isolation and capture of circulating tumor cells and clusters from mouse blood
    Macaraniag, Celine
    Zhou, Jian
    Papautsky, Ian
    Li, Jing
    Putzbach, William
    Hay, Nissim
    CANCER RESEARCH, 2023, 83 (07)