An Amperometric Sensitive Hydrogen Peroxide Sensor Based on a Silver Nanoparticle-Doped Polyimide-Modified Glassy Carbon Electrode

被引:6
|
作者
Chen, Lin [1 ,2 ]
Wang, Yue [1 ]
Ban, Hao [1 ]
Yu, Simin [2 ]
Tao, Dongping [3 ]
Hu, Zhizhi [1 ]
机构
[1] Univ Sci & Technol Liaoning, Sch Chem Engn, High Tech Zone, 185 Qianshan Middle Rd, Anshan 114051, Liaoning, Peoples R China
[2] Yingkou Inst Technol, Dept Chem & Mat Engn, Yingkou 115014, Liaoning, Peoples R China
[3] Univ Sci & Technol Liaoning, Sch Min Engn, High Tech Zone, 185 Qianshan Middle Rd, Anshan 114051, Liaoning, Peoples R China
来源
关键词
polyimide; silver nanoparticle; hydrogen peroxide; electrochemical determination; NONENZYMATIC VOLTAMMETRIC DETERMINATION; REDUCED GRAPHENE OXIDE; GLUCOSE; BIOSENSOR; GEL; NANOSHEETS; ACID;
D O I
10.20964/2018.11.94
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We report a novel non-enzymatic sensor for the detection of hydrogen peroxide based on a polyimide and silver nanoparticle composite-modified glassy carbon electrode. The structure and morphology of the modified electrode surface were characterized by scanning electron microscopy and atomic force microscopy. The electrochemical performance of the present sensor was evaluated by cyclic voltammetry and amperometry. Under optimal conditions, the calibration plots are linear in the range of 0.01-1 mM, with a detection limit (S/N =3) of 8.6 mu M. The electrode exhibited high stability, great sensitivity, stable reproducibility and fast response times (< 5 s). These results show that polyimide can be used as a reliable and long-life sensor for hydrogen peroxide detection, revealing a new application for polyimide.
引用
收藏
页码:10961 / 10972
页数:12
相关论文
共 50 条
  • [31] Amperometric biosensor for hydrogen peroxide based on electrodeposited sub-micrometer gold modified glassy carbon electrode
    Wang, SQ
    Chen, J
    Lin, XQ
    CHINESE JOURNAL OF CHEMISTRY, 2004, 22 (04) : 360 - 364
  • [32] Amperometric Biosensor for Hydrogen Peroxide Based on Electrodeposited Sub-micrometer Gold Modified Glassy Carbon Electrode
    王树青
    陈峻
    林祥钦
    Chinese Journal of Chemistry, 2004, (04) : 360 - 364
  • [33] A Novel Hydrogen Peroxide Sensor Based on Silver Nanoparticles Electrodeposited on PFS-DNA Networks Modified Glassy Carbon Electrode
    He, Z. F.
    Song, Y. H.
    Wang, L.
    Wan, L. L.
    Zhu, H. Z.
    Gao, S.
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (09) : 3837 - 3841
  • [34] Platinum nanoparticle-doped multiwalled carbon-nanotube-modified glassy carbon electrode as a sensor for simultaneous determination of atenolol and propranolol in neutral solution
    Zhao Kun
    Chen Hongtao
    Yuan Yue
    Bao Zhihong
    Lu Fangzheng
    Li Sanming
    IONICS, 2015, 21 (04) : 1129 - 1140
  • [35] Platinum nanoparticle-doped multiwalled carbon-nanotube-modified glassy carbon electrode as a sensor for simultaneous determination of atenolol and propranolol in neutral solution
    Zhao Kun
    Chen Hongtao
    Yuan Yue
    Bao Zhihong
    Lu Fangzheng
    Li Sanming
    Ionics, 2015, 21 : 1129 - 1140
  • [36] A modified glassy carbon electrode for hydrogen peroxide sensing
    Zheng, Cai-yun
    Chen, Shui-hong
    Shang, Yong-jia
    Li, Mao-guo
    ANNALI DI CHIMICA, 2007, 97 (11-12) : 1227 - 1235
  • [37] Electrochemical hydrogen peroxide sensor based on a glassy carbon electrode modified with nanosheets of copper-doped copper(II) oxide
    Song, Haiyan
    Ma, Chaohong
    You, Liyan
    Cheng, Zhenyu
    Zhang, Xinhui
    Yin, Baishuang
    Ni, Yongnian
    Zhang, Keqin
    MICROCHIMICA ACTA, 2015, 182 (7-8) : 1543 - 1549
  • [38] Electrochemical hydrogen peroxide sensor based on a glassy carbon electrode modified with nanosheets of copper-doped copper(II) oxide
    Haiyan Song
    Chaohong Ma
    Liyan You
    Zhenyu Cheng
    Xinhui Zhang
    Baishuang Yin
    Yongnian Ni
    Keqin Zhang
    Microchimica Acta, 2015, 182 : 1543 - 1549
  • [39] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Huaan Zhong
    Ruo Yuan
    Yaqin Chai
    Yu Zhang
    Chengyan Wang
    Feng Jia
    Microchimica Acta, 2012, 176 : 389 - 395
  • [40] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395