An Amperometric Sensitive Hydrogen Peroxide Sensor Based on a Silver Nanoparticle-Doped Polyimide-Modified Glassy Carbon Electrode

被引:6
|
作者
Chen, Lin [1 ,2 ]
Wang, Yue [1 ]
Ban, Hao [1 ]
Yu, Simin [2 ]
Tao, Dongping [3 ]
Hu, Zhizhi [1 ]
机构
[1] Univ Sci & Technol Liaoning, Sch Chem Engn, High Tech Zone, 185 Qianshan Middle Rd, Anshan 114051, Liaoning, Peoples R China
[2] Yingkou Inst Technol, Dept Chem & Mat Engn, Yingkou 115014, Liaoning, Peoples R China
[3] Univ Sci & Technol Liaoning, Sch Min Engn, High Tech Zone, 185 Qianshan Middle Rd, Anshan 114051, Liaoning, Peoples R China
来源
关键词
polyimide; silver nanoparticle; hydrogen peroxide; electrochemical determination; NONENZYMATIC VOLTAMMETRIC DETERMINATION; REDUCED GRAPHENE OXIDE; GLUCOSE; BIOSENSOR; GEL; NANOSHEETS; ACID;
D O I
10.20964/2018.11.94
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We report a novel non-enzymatic sensor for the detection of hydrogen peroxide based on a polyimide and silver nanoparticle composite-modified glassy carbon electrode. The structure and morphology of the modified electrode surface were characterized by scanning electron microscopy and atomic force microscopy. The electrochemical performance of the present sensor was evaluated by cyclic voltammetry and amperometry. Under optimal conditions, the calibration plots are linear in the range of 0.01-1 mM, with a detection limit (S/N =3) of 8.6 mu M. The electrode exhibited high stability, great sensitivity, stable reproducibility and fast response times (< 5 s). These results show that polyimide can be used as a reliable and long-life sensor for hydrogen peroxide detection, revealing a new application for polyimide.
引用
收藏
页码:10961 / 10972
页数:12
相关论文
共 50 条
  • [21] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Wang, Ai-Jun
    Zhang, Pei-Pei
    Li, Yong-Fang
    Feng, Jiu-Ju
    Dong, Wen-Ju
    Liu, Xue-Yan
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 31 - 37
  • [22] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Ai-Jun Wang
    Pei-Pei Zhang
    Yong-Fang Li
    Jiu-Ju Feng
    Wen-Ju Dong
    Xue-Yan Liu
    Microchimica Acta, 2011, 175 : 31 - 37
  • [23] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes—chitosan composite film modified electrode
    Keying Zhang
    Li Zhang
    Jigui Xu
    Cong Wang
    Tao Geng
    Hongyan Wang
    Jun Zhu
    Microchimica Acta, 2010, 171 : 139 - 144
  • [24] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320
  • [25] Selective and Sensitive Nitrite Sensor Based on Glassy Carbon Electrode Modified by Silver Nanochains
    Shaikh, Tayyaba
    Ibupoto, Zaffar Hussain
    Talpur, Farah N.
    Sirajuddin
    Khaskheli, Abdul Rauf
    Agheem, Muhammad H.
    Siddiqui, Samia
    Tahira, Aneela
    Willander, Magnus
    Yu, Cong
    ELECTROANALYSIS, 2017, 29 (02) : 415 - 422
  • [26] An amperometric sensor based on Prussian blue and poly(o-phenylenediamine) modified glassy carbon electrode for the determination of hydrogen peroxide in beverages
    Ping, Jianfeng
    Wu, Jian
    Fan, Kai
    Ying, Yibin
    FOOD CHEMISTRY, 2011, 126 (04) : 2005 - 2009
  • [27] Amperometric ascorbic acid sensor based on doped ferrites nanoparticles modified glassy carbon paste electrode
    Dimitrijevic, Teodora
    Vulic, Predrag
    Manojlovic, Dragan
    Nikolic, Aleksandar S.
    Stankovic, Dalibor M.
    ANALYTICAL BIOCHEMISTRY, 2016, 504 : 20 - 26
  • [28] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes-chitosan composite film modified electrode
    Zhang, Keying
    Zhang, Li
    Xu, Jigui
    Wang, Cong
    Geng, Tao
    Wang, Hongyan
    Zhu, Jun
    MICROCHIMICA ACTA, 2010, 171 (1-2) : 139 - 144
  • [29] Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
    Min-Jung Song
    Sung Woo Hwang
    Dongmok Whang
    Journal of Applied Electrochemistry, 2010, 40 : 2099 - 2105
  • [30] Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
    Song, Min-Jung
    Hwang, Sung Woo
    Whang, Dongmok
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (12) : 2099 - 2105