Concentration-Temporal Multilevel Calibration of Low-Cost PM2.5 Sensors

被引:2
|
作者
Day, Rong-Fuh [1 ]
Yin, Peng-Yeng [2 ]
Huang, Yuh-Chin T. [3 ,4 ]
Wang, Cheng-Yi [5 ,6 ]
Tsai, Chih-Chun [1 ]
Yu, Cheng-Hsien [7 ]
机构
[1] Natl Chi Nan Univ, Dept Informat Management, 1 Univ Rd, Puli 545, Nantou County, Taiwan
[2] Ming Chuan Univ, Informat Technol & Management Program, 5 De Ming Rd, Taoyuan 333, Gui Shan Distri, Taiwan
[3] Duke Univ, Dept Med, Med Ctr, 10 Duke Med Circle, Durham, NC 27710 USA
[4] Duke Univ, Dept Med, Sch Med, 10 Duke Med Circle, Durham, NC 27710 USA
[5] Fu Jen Catholic Univ, Cardinal Tien Hosp, Coll Med, Dept Internal Med, New Taipei 231, Taishan Distric, Taiwan
[6] Fu Jen Catholic Univ, Coll Med, Sch Med, New Taipei 231, Taishan Distric, Taiwan
[7] China Univ Technol, Dept Informat Management, 56,Sec 3,Xinglong Rd, Taipei 116, Wunshan Distric, Taiwan
关键词
PM2.5; supersite sensor; low-cost sensor; multilevel calibration; linear regression; AMBIENT;
D O I
10.3390/su141610015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ambient aerosols have a significant impact on plant species mortality, air pollution, and climate change. It is critical to monitor the concentrations of aerosols, especially particulate matter with an aerodynamic diameter <= 2.5 mu m (PM2.5), which has a direct relationship with human respiratory diseases. Recently, low-cost PM2.5 sensors have been deployed to provide a denser monitoring coverage than that of government-built monitoring supersites, which only give a macro perspective of air quality. To increase the measurement accuracy, low-cost sensors need to be calibrated. In current practice, regression techniques are used to calibrate sensors. This paper proposes a concentration-temporal multilevel calibration method to cope with the varying regression relation in different concentration and temporal domains. The performance of our method is evaluated with real field data from a supersite sensor and a low-cost sensor deployed in Puli, Taiwan. The experimental results show that our calibration method significantly outperforms linear regression in terms of R-2, Root Mean Square Error, and Normalized Mean Error. Moreover, our method compares favorably with a machine learning calibration method based on gradient regression tree boosting.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Real-Time PM2.5 Monitoring in a Diesel Generator Workshop Using Low-Cost Sensors
    Feng, Zikang
    Zheng, Lina
    Liu, Lingyu
    Zhang, Wenli
    ATMOSPHERE, 2022, 13 (11)
  • [42] Feasibility of Using Low-Cost Sensors to Monitor Personal Exposure to PM2.5 Among People with Asthma
    Xie, S.
    Meeker, J.
    Perez, L.
    Eriksen, W.
    Bocage, C.
    Ndicu, G.
    Localio, A.
    Park, H.
    Jen, A.
    Goldstein, M.
    Christie, C.
    Greenblatt, R.
    Barg, F.
    Apter, A. J.
    Himes, B. E.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [43] Spatial-Temporal Analysis of PM2.5 and NO2 Concentrations Collected Using Low-Cost Sensors in Penuelas, Puerto Rico
    Reece, Stephen
    Williams, Ron
    Colon, Maribel
    Southgate, David
    Huertas, Evelyn
    O'Shea, Marie
    Iglesias, Ariel
    Sheridan, Patricia
    SENSORS, 2018, 18 (12)
  • [44] Field performance evaluation of low-cost PM2.5 sensors for enhancing spatial resolution of PM2.5 monitoring: a case study in the smart city of Sejong, Korea
    Sangcheol Kim
    Hayoon Go
    Eunok Bang
    Kyongyong Jung
    Environmental Monitoring and Assessment, 197 (1)
  • [45] High spatio-temporal resolution predictions of PM2.5 using low-cost sensor data
    Kar, Armita
    Ahmed, Mohammed
    May, Andrew A.
    Le, Huyen T. K.
    ATMOSPHERIC ENVIRONMENT, 2024, 326
  • [46] One year evaluation of three low-cost PM2.5 monitors
    Zamora, Misti Levy
    Rice, Jessica
    Koehler, Kirsten
    ATMOSPHERIC ENVIRONMENT, 2020, 235
  • [47] One-Point Calibration of Low-Cost Sensors for Particulate Air Matter (PM) Concentration Measurement
    Russi, Luigi
    Guidorzi, Paolo
    Semprini, Giovanni
    Trentini, Arianna
    Pulvirenti, Beatrice
    SENSORS, 2025, 25 (03)
  • [48] Characterisation and calibration of low-cost PM sensors at high temporal resolution to reference-grade performance
    Bulot, Florentin M. J.
    Ossont, Steven J.
    Morris, Andrew K. R.
    Basford, Philip J.
    Easton, Natasha H. C.
    Mitchell, Hazel L.
    Foster, Gavin L.
    Cox, Simon J.
    Loxham, Matthew
    HELIYON, 2023, 9 (05)
  • [49] Performance calibration of low-cost and portable particular matter (PM) sensors
    Liu, Di
    Zhang, Qiang
    Jiang, Jingkun
    Chen, Da-Ren
    JOURNAL OF AEROSOL SCIENCE, 2017, 112 : 1 - 10
  • [50] An efficient spatiotemporal data calibration approach for the low-cost PM2.5 sensing network: A case study in Taiwan
    Lee, Chieh-Han
    Wang, Yeuh-Bin
    Yu, Hwa-Lung
    ENVIRONMENT INTERNATIONAL, 2019, 130