Concentration-Temporal Multilevel Calibration of Low-Cost PM2.5 Sensors

被引:2
|
作者
Day, Rong-Fuh [1 ]
Yin, Peng-Yeng [2 ]
Huang, Yuh-Chin T. [3 ,4 ]
Wang, Cheng-Yi [5 ,6 ]
Tsai, Chih-Chun [1 ]
Yu, Cheng-Hsien [7 ]
机构
[1] Natl Chi Nan Univ, Dept Informat Management, 1 Univ Rd, Puli 545, Nantou County, Taiwan
[2] Ming Chuan Univ, Informat Technol & Management Program, 5 De Ming Rd, Taoyuan 333, Gui Shan Distri, Taiwan
[3] Duke Univ, Dept Med, Med Ctr, 10 Duke Med Circle, Durham, NC 27710 USA
[4] Duke Univ, Dept Med, Sch Med, 10 Duke Med Circle, Durham, NC 27710 USA
[5] Fu Jen Catholic Univ, Cardinal Tien Hosp, Coll Med, Dept Internal Med, New Taipei 231, Taishan Distric, Taiwan
[6] Fu Jen Catholic Univ, Coll Med, Sch Med, New Taipei 231, Taishan Distric, Taiwan
[7] China Univ Technol, Dept Informat Management, 56,Sec 3,Xinglong Rd, Taipei 116, Wunshan Distric, Taiwan
关键词
PM2.5; supersite sensor; low-cost sensor; multilevel calibration; linear regression; AMBIENT;
D O I
10.3390/su141610015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ambient aerosols have a significant impact on plant species mortality, air pollution, and climate change. It is critical to monitor the concentrations of aerosols, especially particulate matter with an aerodynamic diameter <= 2.5 mu m (PM2.5), which has a direct relationship with human respiratory diseases. Recently, low-cost PM2.5 sensors have been deployed to provide a denser monitoring coverage than that of government-built monitoring supersites, which only give a macro perspective of air quality. To increase the measurement accuracy, low-cost sensors need to be calibrated. In current practice, regression techniques are used to calibrate sensors. This paper proposes a concentration-temporal multilevel calibration method to cope with the varying regression relation in different concentration and temporal domains. The performance of our method is evaluated with real field data from a supersite sensor and a low-cost sensor deployed in Puli, Taiwan. The experimental results show that our calibration method significantly outperforms linear regression in terms of R-2, Root Mean Square Error, and Normalized Mean Error. Moreover, our method compares favorably with a machine learning calibration method based on gradient regression tree boosting.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Towards a hygroscopic growth calibration for low-cost PM2.5 sensors
    Patel, Milan Y.
    Vannucci, Pietro F.
    Kim, Jinsol
    Berelson, William M.
    Cohen, Ronald C.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2024, 17 (03) : 1051 - 1060
  • [2] Spatial calibration and PM2.5 mapping of low-cost air quality sensors
    Chu, Hone-Jay
    Ali, Muhammad Zeeshan
    He, Yu-Chen
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [3] Spatial calibration and PM2.5 mapping of low-cost air quality sensors
    Hone-Jay Chu
    Muhammad Zeeshan Ali
    Yu-Chen He
    Scientific Reports, 10
  • [4] LOW-PROCESSING DATA ENRICHMENT AND CALIBRATION FOR PM2.5 LOW-COST SENSORS
    Stojanovi, Danka B.
    Kleut, Duska N.
    Davidovi, Milos D.
    De Vito, Saverio
    Jovasevi-Stojanovi, Milena, V
    Bartonova, Alena
    Lepioufle, Jean-Marie
    THERMAL SCIENCE, 2023, 27 (3B): : 2229 - 2240
  • [5] Analysis of spatiotemporal PM2.5 concentration patterns in Changwon, Korea, using low-cost PM2.5 sensors
    Song, Bonggeun
    Park, Kyunghun
    Kim, Taehyeung
    Seo, Gyeongho
    URBAN CLIMATE, 2022, 46
  • [6] A System Calibration Model for Mobile PM2.5 Sensing Using Low-Cost Sensors
    Liu, Hao-Min
    Wu, Hsuan-Cho
    Lee, Hu-Chen
    Ho, Yao-Hua
    Chen, Ling-Jyh
    2017 IEEE INTERNATIONAL CONFERENCE ON INTERNET OF THINGS (ITHINGS) AND IEEE GREEN COMPUTING AND COMMUNICATIONS (GREENCOM) AND IEEE CYBER, PHYSICAL AND SOCIAL COMPUTING (CPSCOM) AND IEEE SMART DATA (SMARTDATA), 2017, : 611 - 618
  • [7] Domain Adaptation-Based Deep Calibration of Low-Cost PM2.5 Sensors
    Jha, Sonu Kumar
    Kumar, Mohit
    Arora, Vipul
    Tripathi, Sachchida Nand
    Motghare, Vidyanand Motiram
    Shingare, A. A.
    Rajput, Karansingh A.
    Kamble, Sneha
    IEEE SENSORS JOURNAL, 2021, 21 (22) : 25941 - 25949
  • [8] Temporal and spatial variation of PM2.5 in indoor air monitored by low-cost sensors
    Shen, Huizhong
    Hou, Weiying
    Zhu, Yaqi
    Zheng, Shuxiu
    Ainiwaer, Subinuer
    Shen, Guofeng
    Chen, Yilin
    Cheng, Hefa
    Hu, Jianying
    Wan, Yi
    Tao, Shu
    Science of the Total Environment, 2021, 770
  • [9] Temporal and spatial variation of PM2.5 in indoor air monitored by low-cost sensors
    Shen, Huizhong
    Hou, Weiying
    Zhu, Yaqi
    Zheng, Shuxiu
    Ainiwaer, Subinuer
    Shen, Guofeng
    Chen, Yilin
    Cheng, Hefa
    Hu, Jianying
    Wan, Yi
    Tao, Shu
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 770
  • [10] Evaluation of Low-Cost Sensors for Ambient PM2.5 Monitoring
    Badura, Marek
    Batog, Piotr
    Drzeniecka-Osiadacz, Anetta
    Modzel, Piotr
    JOURNAL OF SENSORS, 2018, 2018