Fast and accurate grid impedance estimation approach for stability analysis of grid-connected inverters

被引:10
|
作者
Mohammed, Nabil [1 ]
Ciobotaru, Mihai [1 ]
机构
[1] Macquarie Univ, Sch Engn, Sydney, NSW, Australia
关键词
Grid-connected inverters; grid impedance; impedance measurement; Nyquist stability; pulse injection; system identification; voltage monitoring; POWER-SYSTEMS; ADAPTIVE-CONTROL; IDENTIFICATION; GENERATION;
D O I
10.1016/j.epsr.2022.107831
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Interactions between grid-connected inverters and the equivalent grid impedance seen at their point of common coupling have been identified as one of the main causes of instability problems. Therefore, the need for real-time monitoring tools to identify grid impedance variations cannot be underrated. Even though existing techniques have shown to estimate the grid impedance accurately, several concerns have remained unsolved. These include the trade-offs between the estimation accuracy and the magnitude and the time duration of the injected disturbance(s). Hence, this paper proposes a fast and accurate grid impedance estimation approach for the application of online impedance-based stability analysis of grid-connected inverter systems. First, the wideband grid impedance is estimated online based on the injection of two triangular pulses, allowing fast and multiple -input multiple-output (MIMO) identification in the synchronous (dq) reference frame. Then, curve fitting of the estimated wideband grid impedances is applied to obtain their parametric models. Afterward, the stability analysis is performed in the dq reference frame based on the generalized Nyquist criterion. The proposed al-gorithm allows accurate stability analysis over all frequencies as it relies on the parametric impedances. Most importantly, to optimize the trade-offs between the power quality and accurate stability analysis, the proposed algorithm is executed again and injects the two pulses disturbances to the grid only if the system operating conditions change (e.g., variations of the grid impedance). It is also applicable to perform the stability analysis while the inverter is still in standby mode. The simulation and experimental results of a 3-phase grid-connected inverter are presented to validate the efficacy of the proposed technique.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] AN IMPROVED IMPEDANCE ESTIMATION METHOD BASED ON POWER VARIATIONS IN GRID-CONNECTED INVERTERS
    Suarez, Jose H.
    Gomes, Hugo M. C.
    Santana, Luan S.
    Sguarezi Filho, Alfeu J.
    Carralero, Leandro L. O.
    Costa, Fabian F.
    2019 IEEE 15TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 5TH IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2019,
  • [22] Adaptive controller based on grid impedance estimation for stable operation of grid-connected inverters under weak grid conditions
    Temiz, Hakan
    Keysan, Ozan
    Demirok, Erhan
    IET POWER ELECTRONICS, 2020, 13 (13) : 2692 - 2705
  • [23] Impedance phase reshaping of LCL-filtered grid-connected inverters to improve the stability in a weak grid
    Du, Yan
    Cui, Linbo
    Yang, Xiangzhen
    Su, Jianhui
    Wang, Fei
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 2921 - 2926
  • [24] Adaptive Control of Grid-Connected Inverters Based on Online Grid Impedance Measurements
    Cespedes, Mauricio
    Sun, Jian
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2014, 5 (02) : 516 - 523
  • [25] Impedance Modeling and Stability Analysis of Grid-connected Inverter Under Unbalanced Grid
    Xie B.
    Li P.
    Su J.
    Zheng W.
    Shi Y.
    Liu T.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (12): : 5196 - 5207
  • [26] Impedance-Based Stability Analysis of Different Current Control Categories of Grid-Connected Inverters
    Ghaderi, Mohammad Hassan
    Rashidirad, Nasim
    Hamzeh, Mohsen
    2018 SMART GRID CONFERENCE (SGC), 2018, : 272 - 277
  • [27] AN IMPEDANCE RESHAPING CONTROL STRATEGY TO ENHANCE ADAPTABILITY TO GRID FOR GRID-CONNECTED INVERTERS
    Ling, Pan
    Peng, Zhang
    Chao, Guo
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 12 - 18
  • [28] Stability Analysis of Grid-Connected Inverters during the Transient of Grid Voltage Fluctuations in Weak Grid Cases
    Xu, Jinming
    Bian, Shenyiyang
    Liu, Miao
    Zhang, Zhao
    Xie, Shaojun
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 5185 - 5190
  • [29] Fundamental grid impedance estimation using grid-connected inverters: a comparison of two frequency-based estimation techniques
    Mohammed, Nabil
    Ciobotaru, Mihai
    Town, Graham
    IET POWER ELECTRONICS, 2020, 13 (13) : 2730 - 2741
  • [30] Stability and Resonance Analysis and Improved Design of N-Paralleled Grid-Connected PV Inverters Coupled Due to Grid Impedance
    Xie, Bao
    Zhou, Lin
    Zheng, Chen
    Zhang, Qianjin
    THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 362 - 367