Impedance Modeling and Stability Analysis of Grid-connected Inverter Under Unbalanced Grid

被引:0
|
作者
Xie B. [1 ]
Li P. [1 ]
Su J. [1 ]
Zheng W. [1 ]
Shi Y. [1 ]
Liu T. [2 ]
机构
[1] Research Center for Photovoltaic Systems Engineering of Ministry of Education, School of Electrical and Automatic Engineering, Hefei University of Technology, Hefei
[2] State Grid Anhui Ultra High Voltage Company, Hefei
来源
关键词
DSOGI-PLL; grid-connected inverter; impedance modeling; StarSim; unbalanced grid;
D O I
10.13336/j.1003-6520.hve.20230410
中图分类号
学科分类号
摘要
In order to analyze the system stability of grid-connected inverter under unbalanced grid, this paper first establishes an output sequence impedance model of grid-connected inverter based on the traditional synchronous reference frame phase locked loop (SRF-PLL). It is found that the negative sequence fundamental frequency voltage of the grid has a negligible influence on the output impedance of the inverter, while the unbalanced three-phase grid impedance will seriously affect the stability of the system. Then, in order to improve the stability of the system under unbalanced grid, a small signal model of dual second order generalized integrator phase locked loop (DSOGI-PLL) is established, and the output sequence impedance model of inverter based on DSOGI-PLL is derived. It is found that DSOGI-PLL can significantaly improve the system stability under the condition of grid voltage imbalance and impedance imbalance. Finally, the corresponding simulation and experimental verification are carried out, and the theory in this paper is confirmed experimentally. © 2023 Science Press. All rights reserved.
引用
收藏
页码:5196 / 5207
页数:11
相关论文
共 25 条
  • [1] HAN Xiaoqing, LI Tingjun, ZHANG Dongxia, Et al., New issues and key technologies of new power system planning under double carbon goals, High Voltage Engineering, 47, 9, pp. 3036-3046, (2021)
  • [2] CHEN X, WANG Y C, GONG C Y, Et al., Overview of stability research for grid-connected inverters based on impedance analysis method[J], Proceedings of the CSEE, 38, 7, pp. 2082-2094, (2018)
  • [3] LI Jinghua, LUO Yichen, YANG Shuhui, Et al., Review of uncertainty forecasting methods for renewable energy power, High Voltage Engineering, 47, 4, pp. 1144-1155, (2021)
  • [4] WANG Yuhong, YE Wei, SONG Ruihua, Et al., Design of additional active damping for three-phase LCL grid connected inverter based on impedance analysis method, High Voltage Engineering, 47, 8, pp. 2645-2654, (2021)
  • [5] XIONG Fei, WU Junyong, HAO Liangliang, Et al., Multi-objective control strategies of grid interface inverter under unbalanced voltage sags, Transactions of China Electrotechnical Society, 32, 1, pp. 107-116, (2017)
  • [6] WANG Jinning, WANG Lei, HAN Xiaoqing, Et al., Analysis on AC/DC harmonic coupling characteristics of converter based on harmonic state space modeling, Automation of Electric Power Systems, 44, 4, pp. 159-167, (2020)
  • [7] KWON J, WANG X F, BAK C L, Et al., The modeling and harmonic coupling analysis of multiple-parallel connected inverter using harmonic state space (HSS), Proceedings of the 2015 IEEE Energy Conversion Congress and Exposition, pp. 6231-6238, (2015)
  • [8] SUN J, BING Z H, KARIMI K J., Input impedance modeling of multipulse rectifiers by harmonic linearization, IEEE Transactions on Power Electronics, 24, 12, pp. 2812-2820, (2009)
  • [9] ZHANG Yang, SHEN Mengjiao, CHEN Xin, Et al., Sequence impedance modeling and analysis of cascaded H-bridge static var generator based on double-harmonic linearization, Transactions of China Electrotechnical Society, 34, 20, pp. 4334-4346, (2019)
  • [10] WANG X F, HARNEFORS L, BLAABJERG F., Unified impedance model of grid-connected voltage-source converters, IEEE Transactions on Power Electronics, 33, 2, pp. 1775-1787, (2018)