Dosimetric evaluation near lung and soft tissue interface region during respiratory-gated and non-gated radiotherapy: A moving phantom study

被引:7
|
作者
Jong, W. L. [1 ]
Ung, N. M. [1 ]
Vannyat, Ath [1 ,2 ]
Rosenfeld, A. B. [3 ]
Wong, J. H. D. [4 ,5 ]
机构
[1] Univ Malaya, Clin Oncol Unit, Fac Med, Kuala Lumpur 50603, Malaysia
[2] Calmette Hosp, Dept Oncol, Phnom Penh, Cambodia
[3] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[4] Univ Malaya, Dept Biomed Imaging, Fac Med, Kuala Lumpur, Malaysia
[5] Univ Malaya, Univ Malaya Res Imaging Ctr, Fac Med, Kuala Lumpur, Malaysia
关键词
MOSFET; Radiochromic film; EBT2; Quality assurance; Margin; Inhomogeneity; Gating technique; STEREOTACTIC BODY RADIOTHERAPY; RADIATION-THERAPY; QUALITY-ASSURANCE; MOSKIN DETECTOR; RESIDUAL MOTION; TUMOR MOTION; CANCER; BEAM; TIME; VERIFICATION;
D O I
10.1016/j.ejmp.2017.08.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Challenges in treating lung tumours are related to the respiratory-induced tumour motion and the accuracy of dose calculation in charged particle disequilibrium condition. The dosimetric characteristics near the interface of lung and Perspex media in a moving phantom during respiratory-gated and non-gated radiotherapy were investigated using Gafchromic EBT2 and the MOSkin detector. The MOSkin detectors showed good agreement with the EBT2 films during static and gated radiotherapy. In static radiotherapy, the penumbral widths were found to be 3.66 mm and 7.22 mm in Perspex and lung media, respectively. In non-gated (moving) radiotherapy with 40 mm respiratory amplitude, dose smearing effect was observed and the penumbral widths were increased to 28.81 mm and 26.40 mm, respectively. This has been reduced to 6.85 mm and 9.81 mm, respectively, in gated radiotherapy with 25% gating window. There were still some dose discrepancies as compared to static radiotherapy due to the residual motion. This should be taken into account in the margin generation for the target tumour. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 34 条
  • [1] Dose profile measurements during respiratory-gated lung stereotactic radiotherapy: A phantom study
    Jong, W. L.
    Wong, J. H. D.
    Ng, K. H.
    Ung, N. M.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [2] Evaluation of respiratory pattern during respiratory-gated radiotherapy
    Dobashi, Suguru
    Mori, Shinichiro
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (04) : 731 - 742
  • [3] Evaluation of respiratory pattern during respiratory-gated radiotherapy
    Suguru Dobashi
    Shinichiro Mori
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 731 - 742
  • [4] Dosimetric evaluations and analyses of a moving target volume treated with respiratory-gated intensity modulated radiotherapy
    Chen, H
    Brandner, E
    Kalnicki, S
    Heron, D
    Komanduri, K
    Wu, A
    MEDICAL PHYSICS, 2004, 31 (06) : 1752 - 1752
  • [5] Dosimetric and clinical benefits of respiratory-gated radiotherapy for lung and breast cancers: Results of the STIC 2003
    Giraud, P.
    Djadi-Prat, J.
    Morvan, E.
    Morelle, M.
    Remmonay, R.
    Pourel, N.
    Durdux, C.
    Carrie, C.
    Mornex, F.
    Le Pechoux, C.
    Bachaud, J. -M.
    Boisselier, P.
    Beckendorf, V.
    Dendale, R.
    Daveau, C.
    Garcia, R.
    CANCER RADIOTHERAPIE, 2012, 16 (04): : 272 - 281
  • [6] Asymmetric margin setting at the cranial and caudal sides in respiratory gated and non-gated stereotactic body radiotherapy for lung cancer
    Ueda, Yoshihiro
    Oohira, Shingo
    Isono, Masaru
    Miyazaki, Masayoshi
    Teshima, Teruki
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1059):
  • [7] Interplay Effect in Non-Gated Dynamic Treatment Delivery of a Lung Phantom with Simulated Respiratory Motion
    Desai, V.
    Fagerstrom, J.
    Bayliss, A.
    Kissick, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 174 - 174
  • [8] Reproducibility of image quality for moving objects using respiratory-gated computed tomography: a study using a phantom model
    Fukumitsu, Nobuyoshi
    Ishida, Masaya
    Terunuma, Toshiyuki
    Mizumoto, Masashi
    Hashimoto, Takayuki
    Moritake, Takashi
    Okumura, Toshiyuki
    Sakae, Takeji
    Tsuboi, Koji
    Sakurai, Hideyuki
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (06) : 945 - 953
  • [9] Analysis of dosimetric impact of intrafraction translation and rotation during respiratory-gated stereotactic body radiotherapy with real-time tumor monitoring of the lung using a novel six degrees-of-freedom robotic moving phantom
    Shiinoki, Takehiro
    Fujii, Fumitake
    Yuasa, Yuki
    Nonomura, Tatsuki
    Fujimoto, Koya
    Sera, Tatsuhiro
    Tanaka, Hidekazu
    MEDICAL PHYSICS, 2020, 47 (09) : 3870 - 3881
  • [10] Analysis of the distribution of dose delivery during respiratory-gated step-and-shoot IMRT for lung cancer radiotherapy
    Xhaferllari, I.
    El-Sherif, O.
    Gaede, S.
    MEDICAL PHYSICS, 2012, 39 (07) : 4634 - 4635