Analysis of dosimetric impact of intrafraction translation and rotation during respiratory-gated stereotactic body radiotherapy with real-time tumor monitoring of the lung using a novel six degrees-of-freedom robotic moving phantom

被引:6
|
作者
Shiinoki, Takehiro [1 ]
Fujii, Fumitake [2 ]
Yuasa, Yuki [1 ]
Nonomura, Tatsuki [2 ]
Fujimoto, Koya [1 ]
Sera, Tatsuhiro [3 ]
Tanaka, Hidekazu [1 ]
机构
[1] Yamaguchi Univ, Grad Sch Med, Dept Radiat Oncol, 1-1-1 Minamikogushi, Ube, Yamaguchi 7558505, Japan
[2] Yamaguchi Univ, Grad Sch Sci & Technol Innovat, Dept Mech Engn, 2-16-1 Tokiwadai, Ube, Yamaguchi 7558611, Japan
[3] Yamaguchi Univ, Dept Radiol Technol, 1-1-1 Minamikogushi, Ube, Yamaguchi 7558505, Japan
基金
日本学术振兴会;
关键词
6DoF robotic moving phantom; intrafraction rotation; respiratory gating; PROSTATE; MOTION; TRACKING; QUANTIFICATION; MANAGEMENT; SYSTEM;
D O I
10.1002/mp.14369
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study aimed to develop a six degrees-of-freedom (6DoF) robotic moving phantom for evaluating the dosimetric impact of intrafraction rotation during respiratory-gated radiotherapy with real-time tumor monitoring in the lung. Materials and Methods Fifteen patients who had undergone respiratory-gated stereotactic body radiotherapy (SBRT) with the SyncTraX system for lung tumors were enrolled in this study. A water-equivalent phantom (WEP) was set at the tip of the robotic arm. A log file that recorded the three-dimensional positions of three fiducial markers implanted near the lung tumor was used as the input to the 6DoF robotic moving phantom. Respiratory-gated radiotherapy was performed for the WEP, which was driven using translational and rotational motions of the lung tumor. The accuracy of the 6DoF robotic moving phantom was calculated as the difference between the actual and the measured positions. To evaluate the dosimetric impact of intrafraction rotation, the absolute dose distributions under conditions involving gating and movement were compared with those under static conditions. Results For the sinusoidal patterns, the mean +/- standard deviation (SD) of the root mean square errors (RMSEs) of the translation and rotation positional errors was <0.40 mm and 0.30 degrees, respectively, for all directions. For the respiratory motion patterns of 15 patients, the mean +/- SD of the RMSEs of the translation and rotation positional errors was <0.55 mm and 0.85 degrees, respectively, for all directions. The gamma(3%/2mm)values under translation with/without gating were 97.6 +/- 2.2%/80.9 +/- 18.1% and 96.8 +/- 2.3%/80.0 +/- 17.0% in the coronal and sagittal planes, respectively. Further, the gamma(3%/2mm)values under rotation with/without gating were 91.5 +/- 6.5%/72.8 +/- 18.6% and 90.3 +/- 6.1%/72.9 +/- 15.7% in the coronal and sagittal planes, respectively. Conclusions The developed 6DoF robotic phantom system could determine the translational and rotational motions of lung tumors with high accuracy. Further, respiratory-gating radiotherapy with real-time tumor monitoring using an internal surrogate marker was effective in compensating for the translational motion of lung tumors but not for correcting their rotational motion.
引用
收藏
页码:3870 / 3881
页数:12
相关论文
共 4 条
  • [1] Dosimetric Impact of Intra-Fraction Lung Tumor Rotation in Real-Time Tumor-Tracking Radiotherapy Using a Developed 6DoF Robotic Phantom System
    Shiinoki, T.
    Fujii, F.
    Yuasa, Y.
    Nonomura, T.
    Fujimoto, K.
    Sera, T.
    Tanaka, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E757 - E757
  • [2] ENDOBRONCHIAL IMPLANTED REAL-TIME RADIOFREQUENCY (RF) TRANSPONDER BEACON GUIDED, RESPIRATORY-GATED, STEREOTACTIC BODY RADIOTHERAPY FOR MOVING LUNG TUMOURS: INTERIM ANALYSIS OF A PROSPECTIVE PHASE I/II COHORT STUDY
    Cheng, Jui Chih
    Venkataraman, Sankar
    Ahmed, Naseer
    Tan, Lawrence
    Kidane, Biniam
    Sasaki, David
    Rathod, Shrinivas
    Sivananthan, Gokulan
    Koul, Rashmi
    Leylek, Ahmet
    Butler, Jim
    McCurdy, Boyd
    Wong, Ralph
    Kim, Julian
    RADIOTHERAPY AND ONCOLOGY, 2022, 174 : S44 - S44
  • [3] Endobronchial Implanted Real-Time Radiofrequency (RF) Transponder Beacon Guided, Respiratory-Gated, Stereotactic Body Radiotherapy for Moving Lung Tumors: Interim Analysis of a Prospective Phase I/II Cohort Study
    Cheng, J. C.
    Buduhan, G.
    Venkataraman, S.
    Bashir, B. M.
    Ahmed, N.
    Tan, L.
    Kidane, B.
    Sasaki, D. K.
    Rathod, S.
    Sivananthan, G.
    Koul, R.
    Leylek, A.
    Butler, J.
    McCurdy, B.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E369 - E369
  • [4] Real-time Monitoring Of A Lung Tumor Region Based On Gamma Evaluation Using Portal Dose Cine Images During Stereotactic Body Radiotherapy
    Mizoguchi, A.
    Arimura, H.
    Yoshidome, S.
    Hirose, T.
    Shioyama, Y.
    Anai, S.
    Nakamura, K.
    Honda, H.
    Toyofuku, F.
    Hirata, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S858 - S858