Evaluation of respiratory pattern during respiratory-gated radiotherapy

被引:9
|
作者
Dobashi, Suguru [1 ,2 ]
Mori, Shinichiro [1 ]
机构
[1] Natl Inst Radiol Sci, Res Ctr Charged Particle Therapy, Inage Ku, Chiba 2638555, Japan
[2] Tohoku Univ, Dept Hlth Sci, Grad Sch Med, Sendai, Miyagi 980, Japan
关键词
Carbon-ion beam; Gating; Respiration; Intrafractional; Interfractional; HEAVY-ION RADIOTHERAPY; 3D TUMOR MOTION; STATISTICAL-ANALYSIS; COMPUTED-TOMOGRAPHY; BREATHING PATTERNS; PARTICLE THERAPY; LUNG-TUMORS; TRACKING; SYSTEM; IRRADIATION;
D O I
10.1007/s13246-014-0310-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The respiratory cycle is not strictly regular, and generally varies in amplitude and period from one cycle to the next. We evaluated the characteristics of respiratory patterns acquired during respiratory gating treatment in more than 300 patients. A total 331 patients treated with respiratory-gated carbon-ion beam therapy were selected from a group of patients with thoracic and abdominal conditions. Respiratory data were acquired for a total of 3,171 fractions using an external respiratory sensing monitor and evaluated for respiratory cycle, duty cycle, magnitude of baseline drift, and intrafractional/interfractional peak inhalation/exhalation positional variation. Results for the treated anatomical sites and patient positioning were compared. Mean +/- A SD res piratory cycle averaged over all patients was 4.1 +/- A 1.3 s. Mean +/- A SD duty cycle averaged over all patients was 36.5 +/- A 7.3 %. Two types of baseline drift were seen, the first decremental and the second incremental. For respiratory peak variation, the mean intrafractional variation in peak-inhalation position relative to the amplitude in the first respiratory cycle (15.5 +/- A 9.3 %) was significantly larger than that in exhalation (7.5 +/- A 4.6 %). Interfractional variations in inhalation (17.2 +/- A 18.5 %) were also significantly greater than those in exhalation (9.4 +/- A 10.0 %). Statistically significant differences were observed between patients in the supine position and those in the prone position in mean respiratory cycle, duty cycle, and intra-/interfractional variations. We quantified the characteristics of the respiratory curve based on a large number of respiratory data obtained during treatment. These results might be useful in improving the accuracy of respiratory-gated treatment.
引用
收藏
页码:731 / 742
页数:12
相关论文
共 50 条
  • [1] Evaluation of respiratory pattern during respiratory-gated radiotherapy
    Suguru Dobashi
    Shinichiro Mori
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 731 - 742
  • [2] Estimation of the Accuracy in Respiratory-Gated Radiotherapy
    Kurosawa, T.
    Tachibana, H.
    Moriya, S.
    Miyakawa, S.
    Sato, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3573 - 3573
  • [3] Evaluation of the MEMS based portable respiratory training system with a tactile sensor for respiratory-gated radiotherapy
    Sun Young Moon
    Myonggeun Yoon
    Mijoo Chung
    Weon Kuu Chung
    Dong Wook Kim
    Journal of the Korean Physical Society, 2017, 71 : 452 - 458
  • [4] Evaluation of the MEMS Based Portable Respiratory Training System with a Tactile Sensor for Respiratory-Gated Radiotherapy
    Moon, Sun Young
    Yoon, Myonggeun
    Chung, Mijoo
    Chung, Weon Kuu
    Kim, Dong Wook
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 71 (08) : 452 - 458
  • [5] Audio-visual biofeedback for respiratory-gated radiotherapy: Impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy
    George, Rohini
    Chung, Theodore D.
    Vedam, Sastry S.
    Ramakrishnan, Viswanathan
    Mohan, Radhe
    Weiss, Elisabeth
    Keall, Paul J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (03): : 924 - 933
  • [6] Analysis of Total Imaging Uncertainty in Respiratory-Gated Radiotherapy
    Suzuki, J.
    Okuda, T.
    Sakaino, S.
    Yokota, N.
    MEDICAL PHYSICS, 2015, 42 (06) : 3301 - 3301
  • [7] DOSIMETRIC ANALYSIS OF RESPIRATORY-GATED RADIOTHERAPY FOR HEPATOCELLULAR CARCINOMA
    Xi, Mian
    Zhang, Li
    Liu, Meng-Zhong
    Deng, Xiao-Wu
    Huang, Xiao-Yan
    Liu, Hui
    MEDICAL DOSIMETRY, 2011, 36 (02) : 213 - 218
  • [8] The clinical implementation of respiratory-gated intensity-modulated radiotherapy
    Keall, Paul
    Vedam, Sastry
    George, Rohini
    Bartee, Chris
    Siebers, Jeffrey
    Lerma, Fritz
    Weiss, Elisabeth
    Chung, Theodore
    MEDICAL DOSIMETRY, 2006, 31 (02) : 152 - 162
  • [9] Dose profile measurements during respiratory-gated lung stereotactic radiotherapy: A phantom study
    Jong, W. L.
    Wong, J. H. D.
    Ng, K. H.
    Ung, N. M.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [10] Investigation of the location effect of external markers in respiratory-gated radiotherapy
    Yan, Hui
    Zhu, Guopei
    Yang, James
    Lu, Mei
    Ajlouni, Munther
    Kim, Jae Ho
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (02): : 57 - 68