A method for improving the accuracy of calibration-free laser-induced breakdown spectroscopy (CF-LIBS) using determined plasma temperature by genetic algorithm (GA)

被引:42
|
作者
Dong, Juan [1 ]
Liang, Long [1 ]
Wei, Jiao [1 ]
Tang, Hongsheng [1 ]
Zhang, Tianlong [1 ]
Yang, Xiaofeng [1 ]
Wang, Kang [2 ]
Li, Hua [1 ]
机构
[1] NW Univ Xian, Coll Chem & Mat Sci, Inst Analyt Sci, Xian 710069, Peoples R China
[2] Changan Univ, Coll Sci, Xian 710064, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
LOCAL THERMODYNAMIC-EQUILIBRIUM; SELF-ABSORPTION; ELEMENTAL ANALYSIS; EMISSION-LINES; SPECTRAL-LINES; CLASSIFICATION; SELECTION;
D O I
10.1039/c4ja00470a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accuracy is still a challenge for classical calibration-free laser-induced breakdown spectroscopic (CF-LIBS) quantitative analysis since absolute theoretical calculation and mathematical models cannot compensate for the self-absorption effect and plasma temperature variability. The aim of this research is to obtain a more accurate plasma temperature which contributes to the precise determination of the elemental composition of unknown samples for CF-LIBS. Herein, an internal reference-external standard with iteration correction (IRESIC) method is proposed to correct for the self-absorption effect and plasma temperature in CF-LIBS based on an internal reference line and one standard sample. The spectral intensities of each species are corrected by an internal reference line via the iteration procedure, and the internal reference line suffers from a negligible self-absorption effect for self-absorption correction. Furthermore, one standard sample matrix-matched with the unknown samples along with the genetic algorithm (GA) is utilized to simulate the accurate plasma temperature of the unknown samples. It is worth mentioning that the GA is used for plasma temperature correction through iteration correction for the first time in CF-LIBS. The proposed method demonstrates a significant improvement in accuracy compared with the classical CF-LIBS in the quantitative analysis of aluminum-bronze alloy samples due to the integrated merits of internal reference line usage and accurate plasma temperature evaluation.
引用
收藏
页码:1336 / 1344
页数:9
相关论文
共 50 条
  • [41] Advancing environmental monitoring: unveiling heavy metals contamination with calibration-free picosecond laser-induced breakdown spectroscopy (CF-PS-LIBS)
    Fayek, Noura
    Tawfik, Walid
    Khalafallah, Ahmed
    Fikry, Mohamed
    JOURNAL OF OPTICS-INDIA, 2025,
  • [42] A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma
    Tognoni, E.
    Cristoforetti, G.
    Legnaloli, S.
    Palleschi, V.
    Salvetti, A.
    Mueller, M.
    Panne, U.
    Gomushkin, I.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (12) : 1287 - 1302
  • [43] Elements analysis of sage (herb) using calibration-free laser-induced breakdown spectroscopy
    Iqbal, J.
    Asghar, H.
    Shah, S. K. H.
    Naeem, M.
    Abbasi, S. A.
    Ali, R.
    APPLIED OPTICS, 2020, 59 (16) : 4927 - 4932
  • [44] Quantitative elemental analysis of steel using calibration-free laser-induced breakdown spectroscopy
    Shah, M. L.
    Pulhani, A. K.
    Gupta, G. P.
    Suri, B. M.
    APPLIED OPTICS, 2012, 51 (20) : 4612 - 4621
  • [45] Calibration free laser-induced breakdown spectroscopy (LIBS) identification of seawater salinity
    Mohamed, Walid Tawfik Y.
    OPTICA APPLICATA, 2007, 37 (1-2) : 5 - 19
  • [46] Calibration-free inverse method for depth-profile analysis with laser-induced breakdown spectroscopy
    Gaudiuso, R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 123 : 105 - 113
  • [47] A new method for calibration-free analysis by Laser-Induced Breakdown Spectroscopy using a time-integrated spectrometer
    Lellouche, Noura
    Cocciaro, Bruno
    Legnaioli, Stefano
    Lorenzetti, Giulia
    Palleschi, Vincenzo
    Poggialini, Francesco
    Raneri, Simona
    Aberkane, Sabrina Messaoud
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2024, 215
  • [48] Element analysis of complex materials by calibration-free laser-induced breakdown spectroscopy
    J. D. Pedarnig
    P. Kolmhofer
    N. Huber
    B. Praher
    J. Heitz
    R. Rössler
    Applied Physics A, 2013, 112 : 105 - 111
  • [49] Element analysis of complex materials by calibration-free laser-induced breakdown spectroscopy
    Pedarnig, J. D.
    Kolmhofer, P.
    Huber, N.
    Praher, B.
    Heitz, J.
    Roessler, R.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2013, 112 (01): : 105 - 111
  • [50] Calibration-free laser-induced breakdown spectroscopy for quantitative elemental analysis of materials
    V K UNNIKRISHNAN
    K MRIDUL
    R NAYAK
    K ALTI
    V B KARTHA
    C SANTHOSH
    G P GUPTA
    B M SURI
    Pramana, 2012, 79 : 299 - 310