A method for improving the accuracy of calibration-free laser-induced breakdown spectroscopy (CF-LIBS) using determined plasma temperature by genetic algorithm (GA)

被引:42
|
作者
Dong, Juan [1 ]
Liang, Long [1 ]
Wei, Jiao [1 ]
Tang, Hongsheng [1 ]
Zhang, Tianlong [1 ]
Yang, Xiaofeng [1 ]
Wang, Kang [2 ]
Li, Hua [1 ]
机构
[1] NW Univ Xian, Coll Chem & Mat Sci, Inst Analyt Sci, Xian 710069, Peoples R China
[2] Changan Univ, Coll Sci, Xian 710064, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
LOCAL THERMODYNAMIC-EQUILIBRIUM; SELF-ABSORPTION; ELEMENTAL ANALYSIS; EMISSION-LINES; SPECTRAL-LINES; CLASSIFICATION; SELECTION;
D O I
10.1039/c4ja00470a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accuracy is still a challenge for classical calibration-free laser-induced breakdown spectroscopic (CF-LIBS) quantitative analysis since absolute theoretical calculation and mathematical models cannot compensate for the self-absorption effect and plasma temperature variability. The aim of this research is to obtain a more accurate plasma temperature which contributes to the precise determination of the elemental composition of unknown samples for CF-LIBS. Herein, an internal reference-external standard with iteration correction (IRESIC) method is proposed to correct for the self-absorption effect and plasma temperature in CF-LIBS based on an internal reference line and one standard sample. The spectral intensities of each species are corrected by an internal reference line via the iteration procedure, and the internal reference line suffers from a negligible self-absorption effect for self-absorption correction. Furthermore, one standard sample matrix-matched with the unknown samples along with the genetic algorithm (GA) is utilized to simulate the accurate plasma temperature of the unknown samples. It is worth mentioning that the GA is used for plasma temperature correction through iteration correction for the first time in CF-LIBS. The proposed method demonstrates a significant improvement in accuracy compared with the classical CF-LIBS in the quantitative analysis of aluminum-bronze alloy samples due to the integrated merits of internal reference line usage and accurate plasma temperature evaluation.
引用
收藏
页码:1336 / 1344
页数:9
相关论文
共 50 条
  • [31] Intrinsic Performance of Monte Carlo Calibration-Free Algorithm for Laser-Induced Breakdown Spectroscopy
    Gornushkin, Igor B.
    Voelker, Tobias
    SENSORS, 2022, 22 (19)
  • [32] Classification of Nephrite Using Calibration-Free Laser Induced Breakdown Spectroscopy (CF-LIBS) with Comparison to Laser Ablation-Time-of-Flight-Mass Spectrometry (LA-TOF-MS)
    Umar, Zeshan Adeel
    Liaqat, Usman
    Ahmed, Rizwan
    Baig, Muhammad Aslam
    ANALYTICAL LETTERS, 2020, 53 (02) : 203 - 216
  • [33] Evaluation of the Calibration-Free and Multivariate Method for Quantitative Analysis in Laser-Induced Breakdown Spectroscopy
    Kumar, R.
    Maurya, G. S.
    Devanathan, A.
    Rai, A. K.
    JOURNAL OF APPLIED SPECTROSCOPY, 2021, 88 (03) : 580 - 588
  • [34] The Influence of Acquisition Delay for Calibration-Free Laser-Induced Breakdown Spectroscopy
    Fu, Hongbo
    Dong, Fengzhong
    Ni, Zhibo
    Wang, Jingge
    APPLIED SPECTROSCOPY, 2016, 70 (03) : 405 - 415
  • [35] Chemical Analysis of Zooplankton by Calibration-Free Laser-Induced Breakdown Spectroscopy
    Sushkov, N., I
    Lobus, N., V
    Seliverstova, I., V
    Labutin, T. A.
    OPTICS AND SPECTROSCOPY, 2020, 128 (09) : 1343 - 1349
  • [36] Evaluation of the Calibration-Free and Multivariate Method for Quantitative Analysis in Laser-Induced Breakdown Spectroscopy
    R. Kumar
    G. S. Maurya
    A. Devanathan
    A. K. Rai
    Journal of Applied Spectroscopy, 2021, 88 : 580 - 588
  • [37] Quantitative Analysis of Slag by Calibration-Free Laser-Induced Breakdown Spectroscopy
    Chen Xing-long
    Dong Feng-zhong
    Wang Qi
    Yu Rong-hua
    Liang Yun-xian
    Wang Jing-ge
    Yang Yang
    Ni Zhi-bo
    Xu Ming-ming
    Wu Bian
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (12) : 3289 - 3293
  • [38] High-Throughput Calibration-Free Laser-Induced Breakdown Spectroscopy
    Matsumura, Tarojiro
    Takahashi, Tomoko
    Nagata, Kenji
    Ando, Yasunobu
    Yada, Akira
    Thornton, Blair
    Kuwatani, Tatsu
    ACS EARTH AND SPACE CHEMISTRY, 2024, 8 (06): : 1259 - 1271
  • [39] Chemical Analysis of Zooplankton by Calibration-Free Laser-Induced Breakdown Spectroscopy
    N. I. Sushkov
    N. V. Lobus
    I. V. Seliverstova
    T. A. Labutin
    Optics and Spectroscopy, 2020, 128 : 1343 - 1349
  • [40] Laser-induced breakdown spectroscopy of archaeological findings with calibration-free inverse method: Comparison with classical laser-induced breakdown spectroscopy and conventional techniques
    Gaudiuso, R.
    Dell'Aglio, M.
    De Pascale, O.
    Loperfido, S.
    Mangone, A.
    De Giacomo, A.
    ANALYTICA CHIMICA ACTA, 2014, 813 : 15 - 24