Monte Carlo Analysis of Silicon Carbide Neutron Detector With Double Conversion Layer

被引:5
|
作者
Zhang, Lilong [1 ]
Wang, Ying [1 ]
Guo, Haomin [1 ]
Hu, Haifan [2 ]
Liu, Yuntao [3 ]
Chen, Size [4 ]
机构
[1] Hangzhou Dianzi Univ, Sch Elect & Informat, Hangzhou 310018, Peoples R China
[2] Aerosp Sci & Technol Corp, Lab X, Inst China 2, Beijing 100854, Peoples R China
[3] Harbin Engn Univ, Coll Informat & Commun Engn, Harbin 150001, Peoples R China
[4] Chinese Acad Sci, Inst Nucl Energy Safety Technol, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
关键词
Neutrons; Detectors; Silicon carbide; Silicon; Thermal analysis; Geometry; Gamma-rays; Neutron detectors; energy deposition; detection efficiency; double conversion layer; RADIATION-DAMAGE; SEMICONDUCTOR; SIMULATION; EFFICIENCY; DESIGN; BORON; HE-3; FILM; PERFORMANCE;
D O I
10.1109/JSEN.2021.3094803
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the performance of SiC-based neutron detector was investigated using GEANT4 toolkit. Thin-film-coated and trench type neutron detectors were considered and their intrinsic detection efficiency were calculated according to the relevant structural parameters, with Low-Level Discriminator (LLD) value fixed at 300 keV. For thin-film-coated detector, the analysis carried out for varied layer thicknesses of B-10 and (LiF)-Li-6 showed that the intrinsic detection efficiency increases with the increase of thickness, and reaches the maximum value at the critical thickness and thereafter found to gradually decrease. Due to the self-absorption effect of the conversion material, the intrinsic detection efficiency of the thin-film-coated SiC neutron detector is limited to less than 5%. Fortunately, the trench type SiC neutron detector can break through this limitation. However, under current process conditions, SiC can only be used for shallow trench etching. In order to increase the neutron detection efficiency as high as possible in the limited trench depth, we have proposed a scheme of filling the trench with a double conversion layer, which can significantly improve the intrinsic detection efficiency of neutrons compared with the traditional trench structure with a single conversion layer. Apart from estimating the intrinsic detection efficiency, the energy deposition spectrum in the SiC detector region by the produced secondary charged particles upon thermal neutron interaction with conversion material(B-10 and (LiF)-Li-6) have also been researched for various structural parameters such as conversion layer thickness, trench width and trench gap of detector.
引用
收藏
页码:20145 / 20155
页数:11
相关论文
共 50 条
  • [41] Monte Carlo simulation of GEM-based for 14 MeV neutron detector
    XiaoDong Wang
    YuLian Zhang
    ChunHui Zhang
    BiTao Hu
    Science China Physics, Mechanics and Astronomy, 2013, 56 : 1740 - 1744
  • [42] Monte Carlo simulation of GEM-based for 14 MeV neutron detector
    WANG XiaoDong
    ZHANG YuLian
    ZHANG ChunHui
    HU BiTao
    Science China(Physics,Mechanics & Astronomy), 2013, (09) : 1740 - 1744
  • [43] A Monte Carlo Model of the Neutron Detector Based on Lithium-Glass Scintillator
    Kuzmin, E. S.
    Bokuchava, G. D.
    Zimin, I. Yu
    Kruglov, A. A.
    Kuchinskiy, N. A.
    Malyshev, V. L.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2021, 64 (02) : 195 - 201
  • [44] A Monte Carlo Model of the Neutron Detector Based on Lithium-Glass Scintillator
    E. S. Kuzmin
    G. D. Bokuchava
    I. Yu. Zimin
    A. A. Kruglov
    N. A. Kuchinskiy
    V. L. Malyshev
    Instruments and Experimental Techniques, 2021, 64 : 195 - 201
  • [45] Detection unit optimization of a neutron searching detector using Monte Carlo Simulations
    Korotkin, S.
    Wengrowicz, U.
    Orion, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 660 (01): : 154 - 161
  • [46] MONTE-CARLO SIMULATIONS OF AN ELECTRIC DOUBLE-LAYER
    SVENSSON, B
    JONSSON, B
    WOODWARD, CE
    JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (05): : 2105 - 2113
  • [47] MONTE-CARLO STUDY OF AN ELECTRICAL DOUBLE-LAYER
    TORRIE, GM
    VALLEAU, JP
    CHEMICAL PHYSICS LETTERS, 1979, 65 (02) : 343 - 346
  • [48] Radiation damage analysis of neutron irradiated double sided wedge microstrip silicon detector
    Borchi, E
    Bruzzi, M
    Catacchini, E
    D'Alessandro, R
    Parrini, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 632 - 635
  • [49] Radiation damage analysis of neutron irradiated double sided wedge microstrip silicon detector
    Borchi, E.
    Bruzzi, M.
    Catacchini, E.
    D'Alessandro, R.
    Parrini, G.
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 1): : 632 - 635
  • [50] Radiation damage analysis of neutron irradiated double sided wedge microstrip silicon detector
    Borchi, E
    Bruzzi, M
    Catacchini, E
    D'Alessandro, R
    Parrini, G
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 494 - 497