Monte Carlo Analysis of Silicon Carbide Neutron Detector With Double Conversion Layer

被引:5
|
作者
Zhang, Lilong [1 ]
Wang, Ying [1 ]
Guo, Haomin [1 ]
Hu, Haifan [2 ]
Liu, Yuntao [3 ]
Chen, Size [4 ]
机构
[1] Hangzhou Dianzi Univ, Sch Elect & Informat, Hangzhou 310018, Peoples R China
[2] Aerosp Sci & Technol Corp, Lab X, Inst China 2, Beijing 100854, Peoples R China
[3] Harbin Engn Univ, Coll Informat & Commun Engn, Harbin 150001, Peoples R China
[4] Chinese Acad Sci, Inst Nucl Energy Safety Technol, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
关键词
Neutrons; Detectors; Silicon carbide; Silicon; Thermal analysis; Geometry; Gamma-rays; Neutron detectors; energy deposition; detection efficiency; double conversion layer; RADIATION-DAMAGE; SEMICONDUCTOR; SIMULATION; EFFICIENCY; DESIGN; BORON; HE-3; FILM; PERFORMANCE;
D O I
10.1109/JSEN.2021.3094803
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the performance of SiC-based neutron detector was investigated using GEANT4 toolkit. Thin-film-coated and trench type neutron detectors were considered and their intrinsic detection efficiency were calculated according to the relevant structural parameters, with Low-Level Discriminator (LLD) value fixed at 300 keV. For thin-film-coated detector, the analysis carried out for varied layer thicknesses of B-10 and (LiF)-Li-6 showed that the intrinsic detection efficiency increases with the increase of thickness, and reaches the maximum value at the critical thickness and thereafter found to gradually decrease. Due to the self-absorption effect of the conversion material, the intrinsic detection efficiency of the thin-film-coated SiC neutron detector is limited to less than 5%. Fortunately, the trench type SiC neutron detector can break through this limitation. However, under current process conditions, SiC can only be used for shallow trench etching. In order to increase the neutron detection efficiency as high as possible in the limited trench depth, we have proposed a scheme of filling the trench with a double conversion layer, which can significantly improve the intrinsic detection efficiency of neutrons compared with the traditional trench structure with a single conversion layer. Apart from estimating the intrinsic detection efficiency, the energy deposition spectrum in the SiC detector region by the produced secondary charged particles upon thermal neutron interaction with conversion material(B-10 and (LiF)-Li-6) have also been researched for various structural parameters such as conversion layer thickness, trench width and trench gap of detector.
引用
收藏
页码:20145 / 20155
页数:11
相关论文
共 50 条
  • [21] Predicting the sensitivity of the beryllium/scintillator layer neutron detector using Monte Carlo and experimental response functions
    Styron, J. D.
    Cooper, G. W.
    Ruiz, C. L.
    Hahn, K. D.
    Chandler, G. A.
    Nelson, A. J.
    Torres, J. A.
    McWatters, B. R.
    Carpenter, Ken
    Bonura, M. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [22] TCAD assisted analysis of Silicon Carbide based Fast Neutron Detector for nuclear applications
    Tripathi, Shivang
    Upadhyay, Chandrakant
    Nagaraj, C. P.
    Devan, K.
    Venkatesan, A.
    Panigrahi, B. K.
    2017 IEEE 12TH NANOTECHNOLOGY MATERIALS AND DEVICES CONFERENCE (NMDC), 2017, : 190 - 191
  • [23] The silicon transition radiation detector:: A full Monte Carlo simulation
    Brigida, M
    Favuzzi, C
    Fusco, P
    Gargano, F
    Giglietto, N
    Giordano, F
    Loparco, F
    Mazziotta, MN
    Mirizzi, N
    Rainò, A
    Rainò, S
    Spinelli, P
    Prest, M
    Vallazza, E
    ADVANCED TECHNOLOGY AND PARTICLE PHYSICS, PROCEEDINGS, 2002, 1 : 597 - 601
  • [24] Silicon Carbide Neutron Detector Development - Computational Support with MCNP
    Zohar, Andrej
    Radulovic, Vladimir
    Snoj, Luka
    Bernat, Robert
    Bakrac, Luka
    Capan, Ivana
    Makino, Takahiro
    30TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2021), 2021,
  • [25] NEUTRON ACTIVATION ANALYSIS OF SILICON CARBIDE
    LOWE, LF
    THOMPSON, HD
    CALI, JP
    ANALYTICAL CHEMISTRY, 1959, 31 (12) : 1951 - 1953
  • [26] CARLO DTS - A MONTE-CARLO CODE FOR THE DUAL THIN SCINTILLATOR NEUTRON DETECTOR
    DIAS, MS
    JOHNSON, RG
    PROGRESS IN NUCLEAR ENERGY, 1990, 24 (1-3) : 295 - 304
  • [27] MCNP-REN: a Monte Carlo tool for neutron detector design
    Abhold, ME
    Baker, MC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (03): : 576 - 584
  • [28] Monte-carlo calculation of the neutron detection efficiency of a foil detector
    Park, S
    Kim, YK
    Ha, JH
    Kim, JK
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2005, 47 (04) : 586 - 591
  • [29] Monte Carlo studies of micromegas as a neutron detector and its track reconstruction
    张毅
    张小东
    王文昕
    杨贺润
    杨正才
    胡碧涛
    中国物理C, 2009, (01) : 42 - 46
  • [30] The Monte-Carlo simulation on the detection efficiency of a scintillator neutron detector
    Luo, Fei
    Liu, Fang
    Wang, Ping
    Sun, Yu-Dong
    2ND ANNUAL INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENTAL & SUSTAINABLE ECOSYSTEM DEVELOPMENT (EESED 2016), 2016, 115 : 72 - 77