Determination of uranium isotopic ratios in biological samples using laser ablation inductively coupled plasma double focusing sector field mass spectrometry with cooled ablation chamber

被引:54
|
作者
Zoriy, MV
Kayser, A
Izmer, A
Pickhardt, C
Becker, JS [1 ]
机构
[1] Res Ctr Juelich, Cent Div Analyt Chem, D-52425 Julich, Germany
[2] Bruker Daltonics Inc, Bremen, Germany
关键词
LA-ICP-MS; isotope ratio measurements; uranium; biological samples;
D O I
10.1016/j.ijms.2004.10.026
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
An analytical procedure has been proposed for the determination of precise uranium isotope ratios in a thin uranium layer on a biological surface by laser ablation inductively coupled plasma sector field mass spectrometry (LA-ICP-MS). A cooled laser ablation chamber using a Peltier element was developed in order to analyze element distribution in thin cross-sections of frozen tissues with a lateral resolution in the mu m range. In order to study the figures of merit of LA-ICP-MS with the cooled laser ablation chamber, one drop (20 mu L U concentration 200 ng mL(-1)), each of the certified isotope reference materials NIST U350 and NIST U930, the uranium isotopic standard CCLU-500 and also a drop of uranium with a natural isotopic pattern was deposited and analyzed on the biological surface (flower leaf). The precision and accuracy of isotope ratio measurements are significantly improved using cooled laser ablation chamber in comparison to non-cooled chamber. The precision of the measurements of isotope ratios in the range of 2.0-1.6% for U-234/U-238, 1.3-0.4% for U-235/U-238 and 2.1-1.0% for U-236/U-238 in selected uranium isotopic standards reference material were determined by microlocal analysis (diameter of laser ablation crater: 15, 25 and 50 mu m) using LA-ICP-MS with a cooled laser ablation chamber. The accuracy of U-234/U-238, U-235/U-238 and U-236/U-238 isotope ratio measurements varied in the range of 4.2-1.1%, 2.4-0.5% and 4.8-1.1%, respectively, and were dependent on the diameter of the laser beam used. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [31] Isotopic Abundance Analysis of Lead in Uranium Particles by Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Wang Wei
    Li Zhi-Ming
    Xu Jiang
    Zhou Guo-Qing
    Zhai Li-Hua
    Li Mei
    Su Yong-Yang
    Wei Guan-Yi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (07) : 1053 - 1058
  • [32] Thickness Determination of Subnanometer Layers Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Hattendorf, Bodo
    Pisonero, Jorge
    Guenther, Detlef
    Bordel, Nerea
    ANALYTICAL CHEMISTRY, 2012, 84 (20) : 8771 - 8776
  • [33] Analysis of soil and sediment samples by laser ablation inductively coupled plasma mass spectrometry
    Baker, SA
    Bi, M
    Aucelio, RQ
    Smith, BW
    Winefordner, JD
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (01) : 19 - 26
  • [34] DETERMINATION OF TRACE IMPURITIES IN URANIUM-OXIDES BY LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    CRAIN, JS
    GALLIMORE, DL
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) : 605 - 610
  • [35] Determination of tin isotope ratios in cassiterite by femtosecond laser ablation multicollector inductively coupled plasma mass spectrometry
    Schulze, Marie
    Ziegerick, Marco
    Horn, Ingo
    Weyer, Stefan
    Vogt, Carla
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 26 - 34
  • [36] BIOIMAGING OF BIOLOGICAL TISSUES BY MEANS OF LASER ABLATION WITH INDUCTIVELY COUPLED OF PLASMA AND MASS SPECTROMETRY
    Tvrdonova, Michaela
    Kanicky, Viktor
    Masarik, Michal
    Polanska, Hana
    Vaculovic, Tomas
    PROCEEDINGS OF INTERNATIONAL PHD STUDENTS CONFERENCE, (MENDELNET 2016), 2016, : 835 - 840
  • [37] Laser ablation inductively coupled plasma mass spectrometry analysis of isotopically heterogeneous uranium materials
    Varga, Zsolt
    Wallenius, Maria
    Nicholl, Adrian
    Mayer, Klaus
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (10) : 4377 - 4385
  • [38] Lead determination in whole blood by laser ablation coupled with inductively coupled plasma mass spectrometry
    Hsieh, Hui-Fang
    Chang, Wei-Shan
    Hsieh, Yi-Kong
    Wang, Chu-Fang
    TALANTA, 2009, 79 (02) : 183 - 188
  • [39] Bioimaging of uranium and thorium in mice organs by laser ablation inductively coupled plasma mass spectrometry
    Xiaoyun Li
    Xiaomei Wang
    Jing Zhou
    Zi-Jian Li
    Linjuan Zhang
    Jian-Qiang Wang
    Journal of Radioanalytical and Nuclear Chemistry, 2023, 332 : 2559 - 2569
  • [40] Quantification strategies for elemental imaging of biological samples using laser ablation-inductively coupled plasma-mass spectrometry
    Hare, Dominic
    Austin, Christine
    Doble, Philip
    ANALYST, 2012, 137 (07) : 1527 - 1537