Determination of uranium isotopic ratios in biological samples using laser ablation inductively coupled plasma double focusing sector field mass spectrometry with cooled ablation chamber

被引:54
|
作者
Zoriy, MV
Kayser, A
Izmer, A
Pickhardt, C
Becker, JS [1 ]
机构
[1] Res Ctr Juelich, Cent Div Analyt Chem, D-52425 Julich, Germany
[2] Bruker Daltonics Inc, Bremen, Germany
关键词
LA-ICP-MS; isotope ratio measurements; uranium; biological samples;
D O I
10.1016/j.ijms.2004.10.026
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
An analytical procedure has been proposed for the determination of precise uranium isotope ratios in a thin uranium layer on a biological surface by laser ablation inductively coupled plasma sector field mass spectrometry (LA-ICP-MS). A cooled laser ablation chamber using a Peltier element was developed in order to analyze element distribution in thin cross-sections of frozen tissues with a lateral resolution in the mu m range. In order to study the figures of merit of LA-ICP-MS with the cooled laser ablation chamber, one drop (20 mu L U concentration 200 ng mL(-1)), each of the certified isotope reference materials NIST U350 and NIST U930, the uranium isotopic standard CCLU-500 and also a drop of uranium with a natural isotopic pattern was deposited and analyzed on the biological surface (flower leaf). The precision and accuracy of isotope ratio measurements are significantly improved using cooled laser ablation chamber in comparison to non-cooled chamber. The precision of the measurements of isotope ratios in the range of 2.0-1.6% for U-234/U-238, 1.3-0.4% for U-235/U-238 and 2.1-1.0% for U-236/U-238 in selected uranium isotopic standards reference material were determined by microlocal analysis (diameter of laser ablation crater: 15, 25 and 50 mu m) using LA-ICP-MS with a cooled laser ablation chamber. The accuracy of U-234/U-238, U-235/U-238 and U-236/U-238 isotope ratio measurements varied in the range of 4.2-1.1%, 2.4-0.5% and 4.8-1.1%, respectively, and were dependent on the diameter of the laser beam used. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [21] Double-pulse laser ablation inductively coupled plasma mass spectrometry
    González, J
    Liu, CY
    Yoo, J
    Mao, XL
    Russo, RE
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (01) : 27 - 31
  • [22] In situ analysis of trace elements and isotope ratios in fish otoliths using laser ablation sector field inductively coupled plasma mass spectrometry
    Thorrold, SR
    Shuttleworth, S
    CANADIAN JOURNAL OF FISHERIES AND AQUATIC SCIENCES, 2000, 57 (06) : 1232 - 1242
  • [23] A viscous film sample chamber for Laser Ablation Inductively Coupled Plasma - Mass Spectrometry
    Monticelli, Damiano
    Civati, Davide
    Giussani, Barbara
    Dossi, Carlo
    Spanu, Davide
    Recchia, Sandro
    TALANTA, 2018, 179 : 100 - 106
  • [24] Determination of Chromium Based on Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Wei, Xing
    Zhou, Jing-Jing
    Liu, Jin-Hui
    Chen, Ming-Li
    Wang, Jian-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (03) : 432 - 439
  • [25] Determination of trace elements in ice core samples by Laser ablation Inductively Coupled Plasma Mass Spectrometry
    Reinhardt, H
    Kriews, M
    Schrems, O
    Lüdke, C
    Hoffmann, E
    Skole, J
    PLASMA SOURCE MASS SPECTROMETRY: THE NEW MILLENNIUM, 2001, (267): : 185 - 194
  • [27] Precise determination of element/calcium ratios in calcareous samples using sector field inductively coupled plasma mass spectrometry
    Rosenthal, Y
    Field, MP
    Sherrell, RM
    ANALYTICAL CHEMISTRY, 1999, 71 (15) : 3248 - 3253
  • [28] Precise determination of element/calcium ratios in calcareous samples using sector field inductively coupled plasma mass spectrometry
    Rosenthal, Yair
    Field, M. Paul
    Sherrell, Robert M.
    Analytical Chemistry, 71 (15): : 3248 - 3253
  • [29] Determination of Zr isotopic ratios in zircons using laser-ablation multiple-collector inductively coupled-plasma mass-spectrometry
    Zhang, Wen
    Wang, Zaicong
    Moynier, Frederic
    Inglis, Edward
    Tian, Shengyu
    Li, Ming
    Liu, Yongsheng
    Hu, Zhaochu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (09) : 1800 - 1809
  • [30] APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY FOR DETERMINATION OF URANIUM AND PLUTONIUM CONTENT AND ISOTOPIC RATIOS IN ENVIRONMENTAL SAMPLES
    Nikolaeva, Irina
    Chirko, Oksana
    Palesskiy, Stanislav
    Melgunov, Mikhail
    10TH INTERNATIONAL MULTIDISCIPLINARY SCIENTIFIC GEOCONFERENCE: SGEM 2010, VOL II, 2010, : 413 - 418