Effect of Implant Materials on Bone Remodelling Around Cemented Acetabular Cup

被引:4
|
作者
Kumar, Ajay [1 ]
Ghosh, Rajesh [1 ]
Kumar, Rajeev [1 ]
机构
[1] Indian Inst Technol Mandi, Sch Engn, Kamand 175005, Himachal Prades, India
关键词
Acetabular cup; Implant material; Bone remodelling; TOTAL HIP-REPLACEMENT; STRESS DISTRIBUTIONS; THICKNESS; FATIGUE; MANTLE; FAILURE; COMPONENT; REGION;
D O I
10.1007/978-981-16-0550-5_3
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Bone resorption around cemented acetabular cup caused failure in the long tenure. This study aims to investigate the effect of different implant materials on bone remodelling around the cemented acetabular cup. Finite element (FE) models of intact and implanted pelvic models were established using CT-scan data sets. Three combinations (acetabular cup-femoral head) of implant materials, UHMWPE-CoCrMo, CoCrMo-CoCrMo, and alumina-alumina ceramic, were considered to predict the effect of implant materials on bone remodelling around cemented acetabular cup. Less bone resorption was observed for UHMWPE acetabular cup. Bone remodelling was nearly similar for the ceramic and metallic cup. Considering the bone remodelling scenario, the results of the current study stated that ceramic could be a good alternative to metallic implant in the cemented acetabular cup since ceramic has better wear resistance property than metal.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 50 条
  • [21] Bone impaction grafting and a cemented cup after acetabular fracture at 3-18 years
    Schreurs, BW
    Zengerink, M
    Welten, MLM
    van Kampen, A
    Slooff, TJJH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (437) : 145 - 151
  • [22] Acetabular Cup Stiffness and Implant Orientation Change Acetabular Loading Patterns
    Small, Scott R.
    Berend, Michael E.
    Howard, Leah A.
    Tunc, Didem
    Buckley, Christine A.
    Ritter, Merrill A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (02): : 359 - 367
  • [23] Cortical and interfacial bone changes around a non-cemented hip implant: Simulations using a combined strain/damage remodelling algorithm
    Scannell, Paul T.
    Prendergast, Patrick J.
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (04) : 477 - 488
  • [24] New acetabulum bone formation after 10-years impaction bone graft and cemented acetabular cup lead to simple revision-THA with cementless acetabular cup: A case report
    Rahmansyah, Nur
    Santoso, Asep
    Anwar, Iwan Budiwan
    Sibarani, Tangkas S. M. H. S.
    Mariyanto, Ismail
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2022, 95
  • [25] Parameteric optimisation of materials for acetabular cup
    Hedia, HS
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2001, 11 (02) : 79 - 88
  • [26] Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation
    Basil Mathai
    Santanu Dhara
    Sanjay Gupta
    Biomechanics and Modeling in Mechanobiology, 2021, 20 : 1115 - 1134
  • [27] Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation
    Mathai, Basil
    Dhara, Santanu
    Gupta, Sanjay
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021,
  • [28] A cemented cup with acetabular impaction bone grafting is more cost-effective than an uncemented cup in patients under 50 years
    Busch, Vincent J. J. F.
    Verschueren, Joost
    Adang, Eddy M.
    Lie, Stein A.
    Havelin, Leif I.
    Schreurs, Berend W.
    HIP INTERNATIONAL, 2016, 26 (01) : 43 - 49
  • [29] Acetabular reconstruction with impacted bone allografts and cemented acetabular components
    Comba, F.
    Buttaro, M.
    Pusso, R.
    Piccaluga, F.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07): : 865 - 869
  • [30] Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation
    Mathai, Basil
    Dhara, Santanu
    Gupta, Sanjay
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021, 20 (03) : 1115 - 1134