Macular versus Retinal Nerve Fiber Layer Parameters for Diagnosing Manifest Glaucoma A Systematic Review of Diagnostic Accuracy Studies

被引:98
|
作者
Oddone, Francesco [1 ]
Lucenteforte, Ersilia [2 ]
Michelessi, Manuele [1 ]
Rizzo, Stanislao [3 ]
Donati, Simone [4 ]
Parravano, Mariacristina [1 ]
Virgili, Gianni [3 ]
机构
[1] Fdn GB Bietti Studio Ric Oftalmolol IRCCS, Ophthalmol, Rome, Italy
[2] Univ Florence, Dept Neurosci Psychol Drug Res & Childrens Hlth, Viale Gaetano Pieraccini 6, I-50139 Florence, Italy
[3] Univ Florence, Eye Clin, Dept Translat Surg & Med, Viale Gaetano Pieraccini 6, I-50139 Florence, Italy
[4] Univ Insubria, Dept Surg & Morphol Sci, Sect Ophthalmol, Varese Como, Italy
关键词
OPTICAL COHERENCE TOMOGRAPHY; GANGLION-CELL COMPLEX; SPECTRAL-DOMAIN OCT; OPEN-ANGLE GLAUCOMA; PREPERIMETRIC GLAUCOMA; THICKNESS MEASUREMENTS; POSTERIOR POLE; HIGH MYOPIA; SCANNING PROTOCOLS; ASYMMETRY-ANALYSIS;
D O I
10.1016/j.ophtha.2015.12.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Topic: Macular parameters have been proposed as an alternative to retinal nerve fiber layer (RNFL) parameters to diagnose glaucoma. Comparing the diagnostic accuracy of macular parameters, specifically the ganglion cell complex (GCC) and ganglion cell inner plexiform layer (GCIPL), with the accuracy of RNFL parameters for detecting manifest glaucoma is important to guide clinical practice and future research. Methods: Studies using spectral domain optical coherence tomography (SD OCT) and reporting macular parameters were included if they allowed the extraction of accuracy data for diagnosing manifest glaucoma, as confirmed with automated perimetry or a clinician's optic nerve head (ONH) assessment. Cross-sectional cohort studies and case-control studies were included. The QUADAS 2 tool was used to assess methodological quality. Only direct comparisons of macular versus RNFL parameters (i.e., in the same study) were conducted. Summary sensitivity and specificity of each macular or RNFL parameter were reported, and the relative diagnostic odds ratio (DOR) was calculated in hierarchical summary receiver operating characteristic (HSROC) models to compare them. Results: Thirty-four studies investigated macular parameters using RTVue OCT (Optovue Inc., Fremont, CA) (19 studies, 3094 subjects), Cirrus OCT (Carl Zeiss Meditec Inc., Dublin, CA) (14 studies, 2164 subjects), or 3D Topcon OCT (Topcon, Inc., Tokyo, Japan) (4 studies, 522 subjects). Thirty-two of these studies allowed comparisons between macular and RNFL parameters. Studies generally reported sensitivities at fixed specificities, more commonly 0.90 or 0.95, with sensitivities of most best-performing parameters between 0.65 and 0.75. For all OCT devices, compared with RNFL parameters, macular parameters were similarly or slightly less accurate for detecting glaucoma at the highest reported specificity, which was confirmed in analyses at the lowest specificity. Included studies suffered from limitations, especially the case-control study design, which is known to overestimate accuracy. However, this flaw is less relevant as a source of bias in direct comparisons conducted within studies. Conclusions: With the use of OCT, RNFL parameters are still preferable to macular parameters for diagnosing manifest glaucoma, but the differences are small. Because of high heterogeneity, direct comparative or randomized studies of OCT devices or OCT parameters and diagnostic strategies are essential. (C) 2016 by the American Academy of Ophthalmology.
引用
收藏
页码:939 / 949
页数:11
相关论文
共 50 条
  • [21] Evaluation of Interocular Retinal Nerve Fiber Layer Thickness Symmetry as a Diagnostic Modality for Glaucoma
    Hong, Seung Woo
    Lee, Seung Bum
    Jee, Dong-hyun
    Ahn, Myung Douk
    JOURNAL OF GLAUCOMA, 2016, 25 (09) : E763 - E771
  • [22] Reduced Macular Vessel Density in Glaucoma Suspects correlates with abnormal Pattern Electroretinogram Parameters and Retinal Nerve Fiber Layer Thinning
    Lacher, Corey Ross
    Tirsi, Andrew
    Orshan, Derek
    Gupta, Rohun
    Tsai, Joby
    Gliagias, Vasiliki
    Tello, Sofia
    Derr, Peter
    Tello, Celso
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [23] Diagnostic accuracy of optic disc, macular and retinal nerve fiber layer analysis by means of SD-OCT at different stages of the glaucoma disease: Multicentric Italian Glaucoma Imaging Study (MIGIS).
    Michelessi, Manuele
    Riva, Ivano
    Miglior, Stefano
    Quaranta, Luciano
    Martini, Enrico
    Frezzotti, Paolo
    Figus, Michele
    Manni, Gianluca
    Agnifili, Luca
    Posarelli, Chiara
    Calandriello, Luigi
    Oddone, Francesco
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [24] Glaucoma Diagnostic Accuracy of Machine Learning Classifiers Using Retinal Nerve Fiber Layer and Optic Nerve Data from SD-OCT
    Barella, Kleyton Arlindo
    Costa, Vital Paulino
    Vidotti, Vanessa Goncalves
    Silva, Fabricio Reis
    Dias, Marcelo
    Gomi, Edson Satoshi
    JOURNAL OF OPHTHALMOLOGY, 2013, 2013
  • [25] Ethnic Differences in the Relationship of Axial Length With Macular and Retinal Nerve Fiber Layer Parameters
    Tariq, Y. M.
    Samarawickrama, C.
    Pai, A.
    Burlutsky, G.
    Mitchell, P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [26] Association of Birth Parameters with OCT Measured Macular and Retinal Nerve Fiber Layer Thickness
    Tariq, Yasser M.
    Pai, Amy
    Li, Haitao
    Afsari, Sonia
    Gole, Glen A.
    Burlutsky, George
    Mitchell, Paul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1709 - 1715
  • [27] Macular versus nerve fibre layer versus optic nerve head imaging for diagnosing glaucoma at different stages of the disease: Multicenter Italian Glaucoma Imaging Study
    Michelessi, Manuele
    Riva, Ivano
    Martini, Enrico
    Figus, Michele
    Frezzotti, Paolo
    Agnifili, Luca
    Manni, Gianluca
    Quaranta, Luciano
    Miglior, Stefano
    Posarelli, Chiara
    Fazio, Stefano
    Oddone, Francesco
    ACTA OPHTHALMOLOGICA, 2019, 97 (02) : E207 - E215
  • [28] Ganglion cell analysis versus retinal nerve fiber layer thickness in glaucoma diagnosis
    Soliman, Tarek Tawfik
    Gad, Elham Abd Alazeem
    Selim, Sarah Mohamed
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2019, 112 (04) : 122 - 129
  • [29] Influence of OCT Signal Strength on Macular, Optic Nerve Head, and Retinal Nerve Fiber Layer Parameters
    Samarawickrama, Chameen
    Pai, Amy
    Huynh, Son C.
    Burlutsky, George
    Wong, Tien Y.
    Mitchell, Paul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (09) : 4471 - 4475
  • [30] Minimum Rim Width and Peripapillary Retinal Nerve Fiber Layer Thickness for Diagnosing Early to Moderate Glaucoma
    Zangalli, Camila S.
    Jammal, Alessandro A.
    Reis, Alexandre S. C.
    Ayub, Gabriel
    Diniz-Filho, Alberto
    Paranhos, Augusto
    Paula, Jayter S.
    Costa, Vital P.
    JOURNAL OF GLAUCOMA, 2023, 32 (06) : 526 - 532