Present limitations of CVD diamond detectors for IMRT applications

被引:24
|
作者
De Angelis, C. [1 ]
Casati, M. [2 ]
Bruzzi, M. [3 ]
Onori, S. [1 ]
Bucciolini, M. [2 ]
机构
[1] Ist Super Sanita, INFN, Dipartimento Tecnol & Salute, I-00161 Rome, Italy
[2] Univ Florence, INFN, Dipartimento Fisiopatol, I-50121 Florence, Italy
[3] Univ Florence, INFN, Dipartimento Engn, I-50121 Florence, Italy
关键词
CVD diamond detector; solid-state dosimetry; IMRT dosimetry;
D O I
10.1016/j.nima.2007.08.186
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of the work was to test the suitability of chemical vapor deposited (CVD) diamond detectors for dosimetry in IMRT fields. We used in-house CVD detectors prepared with state-of-the-art polycrystalline diamond films (Element Six Ltd., UK). The parameters considered were time stability, dynamic response, dose-rate dependence and energy dependence. Output factors and TPR were measured in conventional photon fields and dose measurements were performed in IMRT fields using the step-and-shoot technique. Results prove that CVD diamond detectors are suitable for dosimetry in conventional treatments, but they still do not fit the IMRT dosimetry requirements, mainly because of their slow dynamic response. In particular, the slow dynamics affects linearity at low Monitor Units and renders it impossible to follow the sharp transients of IMRT fields. Time stability and dose-rate dependence as well must be improved to reduce their influence on dose assessment. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 50 条
  • [31] Blue light sensitization of CVD diamond detectors
    Manfredotti, C
    Vittone, E
    Paolini, C
    Olivero, P
    Lo Giudice, A
    DIAMOND AND RELATED MATERIALS, 2003, 12 (3-7) : 662 - 666
  • [32] Printed silver contacts to CVD diamond detectors
    Fraimovitch, D.
    Erez, E.
    Ruzin, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 927 : 349 - 352
  • [33] Broadband electronics for CVD-diamond detectors
    Moritz, P
    Berdermann, E
    Blasche, K
    Stelzer, H
    Voss, B
    DIAMOND AND RELATED MATERIALS, 2001, 10 (9-10) : 1765 - 1769
  • [34] Performance of CVD diamond alpha particle detectors
    Zhang, ML
    Xia, YB
    Wang, LJ
    Shen, HJ
    Gu, BB
    SOLID STATE COMMUNICATIONS, 2004, 130 (08) : 551 - 555
  • [35] Reproducibility of CVD diamond detectors for radiotherapy dosimetry
    Betzel, G. T.
    Lansley, S. P.
    McKay, D.
    Meyer, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 691 : 34 - 38
  • [36] Optical applications of CVD diamond
    Pickles, CSJ
    Madgwick, TD
    Sussmann, RS
    Hall, CE
    INDUSTRIAL DIAMOND REVIEW, 2000, 60 (04): : 293 - +
  • [37] Polycrystalline CVD diamond dosimeters for Intensity Modulated Radiotherapy (IMRT)
    Bruzzi, M.
    de Sio, A.
    Pace, E.
    Scaringella, M.
    Talamonti, C.
    Zani, M.
    Bucciolini, M.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [38] Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring
    Curtoni, S.
    Gallin-Martel, M-L
    Marcatili, S.
    Abbassi, L.
    Bes, A.
    Bosson, G.
    Collot, J.
    Crozes, T.
    Dauvergne, D.
    De Nolf, W.
    Everaere, P.
    Gallin-Martel, L.
    Ghimouz, A.
    Haddad, F.
    Hoarau, C.
    Hostachy, J-Y
    Koumeir, C.
    Lacoste, A.
    Metivier, V
    Morse, J.
    Motte, J-F
    Muraz, J-F
    Poirier, F.
    Rarbi, F. E.
    Rossetto, O.
    Salome, M.
    Servagent, N.
    Testa, E.
    Yamouni, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1015
  • [39] Effects of the film microstructures on CVD diamond radiation detectors
    Zhang, ML
    Xia, YB
    Wang, LJ
    Gu, BB
    JOURNAL OF CRYSTAL GROWTH, 2005, 277 (1-4) : 382 - 387
  • [40] On the dose response of some CVD diamond thermoluminescent detectors
    Marczewska, B.
    Bilski, P.
    Olko, P.
    Nesladek, M.
    Rebisz, M.
    Guerrero, M. J.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 319 - 322