Combined detection of C-reactive protein and PBMC quantification from whole blood in an integrated lab-on-a-disc microfluidic platform

被引:18
|
作者
Uddin, Rokon [1 ]
Donolato, Marco [2 ]
Hwu, En-Te [1 ]
Hansen, Mikkel Fougt [1 ]
Boisen, Anja [1 ]
机构
[1] Tech Univ Denmark, Dept Micro & Nanotechnol, DTU Nanotech, Bldg 345B, DK-2800 Lyngby, Denmark
[2] BluSense Diagnost, Fruebjergvej 3, DK-2100 Copenhagen O, Denmark
基金
新加坡国家研究基金会; 欧洲研究理事会;
关键词
CRP; PBMC; Centrifugal microfluidics; Magnetic beads; Optomagnetic readout; Optical imaging; CELL COUNT; AGGLUTINATION ASSAY; CRP DETECTION; RISK; SENSITIVITY; IMMUNOASSAY; INFECTIONS; MORTALITY;
D O I
10.1016/j.snb.2018.07.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is an increasing need for portable and low-cost diagnostic devices for detecting inflammatory/infectious diseases in a rapid and user-friendly fashion. Here, we present a lab-on-a-disc solution, which performs automated sample pre-treatment and combinedly detects small molecules and counts cells in a whole blood sample with a volume of 8.75 mu L with a sample to answer time of 14 min. It is used to detect two common inflammation/ infection biomarkers, C-reactive protein (CRP) and peripheral blood mononuclear cell (PBMC) count. The whole blood sample was separated into plasma and PBMC fractions using density gradient centrifugation and centrifugo- pneumatic valving. On-disc CRP detection was performed in the extracted plasma using a CRP-antibodyfunctionalized magnetic nanobead (MNB)-based agglutination assay and a Blu-ray-based optomagnetic detection unit. On-disc PBMC scanning and quantification was performed using an optical imaging unit. Both detection units were integrated on the centrifugal platform and the entire study was automated in order to ensure reliability of the assay and user-friendliness of the method. We measured the CRP level of subjects with different CRP levels and obtained approximately 73% PBMC extraction efficiency compared to hospital results. The concurrent/ combined detection of these two common biomarkers in an automated microfluidic platform with integrated detection units and with a low sample-to-answer time is a significant step forward towards a low-cost, out-of-lab, and portable tool to detect multiple biomarkers of significantly different nature (molecules and cells).
引用
收藏
页码:634 / 642
页数:9
相关论文
共 50 条
  • [1] One-step Target Protein Detection from Whole Blood in a Lab-on-a-Disc
    Lee, B. S.
    Lee, J. -G.
    Lee, J. -N.
    Park, J. -M.
    Cho, Y. -K.
    Kim, S.
    Ko, C.
    NSTI NANOTECH 2008, VOL 3, TECHNICAL PROCEEDINGS: MICROSYSTEMS, PHOTONICS, SENSORS, FLUIDICS, MODELING, AND SIMULATION, 2008, : 241 - +
  • [2] Electrospun TiO2 nanofiber integrated lab-on-a-disc for ultrasensitive protein detection from whole blood
    Lee, Won Seok
    Sunkara, Vijaya
    Han, Ja-Ryoung
    Park, Yang-Seok
    Cho, Yoon-Kyoung
    LAB ON A CHIP, 2015, 15 (02) : 478 - 485
  • [3] Detection of C-reactive protein in a portable microfluidic immunosensor from whole human blood
    Pytka, Alex S.
    Faghri, Mohammed
    Anagnostopoulos, Constantine
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2016, 6 (05): : 1475 - 1482
  • [4] Fully integrated lab-on-a-disc for simultaneous analysis of biochemistry and immunoassay from whole blood
    Lee, Beom Seok
    Lee, Yang Ui
    Kim, Han-Sang
    Kim, Tae-Hyeong
    Park, Jiwoon
    Lee, Jeong-Gun
    Kim, Jintae
    Kim, Hanshin
    Lee, Wee Gyo
    Cho, Yoon-Kyoung
    LAB ON A CHIP, 2011, 11 (01) : 70 - 78
  • [5] A highly integrated lab-on-a-disc immunoturbidimetric assay from whole blood with on-chip calibration
    Jiachen Yang
    Ya Zhang
    Guozhen Liu
    Shiqi Zhou
    Yanyan Xia
    Zhiyang Li
    Changbin Zhang
    Guanghui Wang
    Microfluidics and Nanofluidics, 2022, 26
  • [6] A highly integrated lab-on-a-disc immunoturbidimetric assay from whole blood with on-chip calibration
    Yang, Jiachen
    Zhang, Ya
    Liu, Guozhen
    Zhou, Shiqi
    Xia, Yanyan
    Li, Zhiyang
    Zhang, Changbin
    Wang, Guanghui
    MICROFLUIDICS AND NANOFLUIDICS, 2022, 26 (02)
  • [7] A microfluidic lab-on-a-disc integrated loop mediated isothermal amplification for foodborne pathogen detection
    Sayad, Abkar Ahmed
    Ibrahim, Fatimah
    Uddin, Shah Mukim
    Pei, Koh Xiu
    Mohktar, Mas S.
    Madou, Marc
    Kwai Lin Thong
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 227 : 600 - 609
  • [8] An integrated microfluidic system for fast, automatic detection of C-reactive protein
    Lee, Wen-Bin
    Chen, Yin-He
    Lin, Hsin-I
    Shiesh, Shu-Chu
    Lee, Gwo-Bin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02): : 710 - 721
  • [9] A MICROFLUIDIC SYSTEM INTEGRATED WITH OPTICAL DETECTION DEVICES FOR AUTOMATIC DETECTION OF C-REACTIVE PROTEIN
    Lee, Wen-Bin
    Chen, Yin-He
    Lin, Hsin-, I
    Huang, Chao-June
    Shiesh, Shu-Chu
    Lee, Gwo-Bin
    MEMS 2010: 23RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2010, : 979 - 982
  • [10] An integrated microfluidic system for C-reactive protein measurement
    Yang, Yi-Ning
    Lin, Hsin-I
    Wang, Jung-Hao
    Shiesh, Shu-Chu
    Lee, Gwo-Bin
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (10): : 3091 - 3096