A highly integrated lab-on-a-disc immunoturbidimetric assay from whole blood with on-chip calibration

被引:5
|
作者
Yang, Jiachen [1 ,2 ]
Zhang, Ya [1 ,2 ]
Liu, Guozhen [1 ,2 ]
Zhou, Shiqi [1 ,2 ]
Xia, Yanyan [3 ]
Li, Zhiyang [3 ]
Zhang, Changbin [5 ]
Wang, Guanghui [1 ,2 ,4 ]
机构
[1] Nanjing Univ, Key Lab Intelligent Opt Sensing & Integrat, Minist Educ, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Univ, Coll Engn & Appl Sci, Nanjing 210093, Jiangsu, Peoples R China
[3] Nanjing Univ, Dept Lab Med, Drum Tower Hosp, Med Sch, Nanjing 210008, Jiangsu, Peoples R China
[4] Nanjing Univ, Inst Opt Commun Engn, Nanjing 210093, Jiangsu, Peoples R China
[5] Nanjing Univ Chinese Med, Nanjing 210023, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
IgA identification; Whole blood sample; Centrifugal microfluidic; POCT; MICROFLUIDIC DEVICE; PLASMA; TECHNOLOGIES; PLATFORM;
D O I
10.1007/s10404-021-02515-x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Human immune dysfunction will cause a variety of immune system diseases, so the detection of immune-related indicators (immunoglobulin and complement) has been increasingly attractive. However, for most commercial biochemical analysers, sample pre-treatment and analysis are tedious, nonportable because processes are separated and professional operations are needed. Therefore, the applications in Point-of-Care testing (POCT) are limited. In this paper, we present a highly integrated immunoturbidimetric assay for immune globulin identification from whole blood sample, based on the centrifugal microfluidic or lab-on-a-disc (LOAD) platform with an embedded self-calibrated absorbance detection system. When compared with traditional methods, our platform is low-cost, portable because of the reduction of manual steps and testing time. At the step of blood pre-treatment, the chip provides the platform for on-chip sedimentation of blood cells and onsite extraction of purified plasma by a novel capillary siphon valve during spinning. The chip is integrated with an on-chip calibration unit to obtain more accurate standard curves and reduce the effect of chip fluctuation. Then, better measurement accuracy will be received. As an application, we conducted Immunoglobulin A (IgA) identification in human whole blood based on our LOAD system. To increase the throughput, we further design a parallel multisample chip with only two critical calibration points. Our LOAD system was demonstrated to have good accuracy (CV: 4.23%), good sensitivity (limit of detection: 0.206 gL(-1)) and high repeatability. The experimental results are in good agreement with those measured by conventional method. Clearly, our LOAD system provides a solution for immunological detection on rotating disc.
引用
收藏
页数:12
相关论文
共 28 条
  • [1] A highly integrated lab-on-a-disc immunoturbidimetric assay from whole blood with on-chip calibration
    Jiachen Yang
    Ya Zhang
    Guozhen Liu
    Shiqi Zhou
    Yanyan Xia
    Zhiyang Li
    Changbin Zhang
    Guanghui Wang
    Microfluidics and Nanofluidics, 2022, 26
  • [2] Fully integrated lab-on-a-disc for simultaneous analysis of biochemistry and immunoassay from whole blood
    Lee, Beom Seok
    Lee, Yang Ui
    Kim, Han-Sang
    Kim, Tae-Hyeong
    Park, Jiwoon
    Lee, Jeong-Gun
    Kim, Jintae
    Kim, Hanshin
    Lee, Wee Gyo
    Cho, Yoon-Kyoung
    LAB ON A CHIP, 2011, 11 (01) : 70 - 78
  • [3] Electrospun TiO2 nanofiber integrated lab-on-a-disc for ultrasensitive protein detection from whole blood
    Lee, Won Seok
    Sunkara, Vijaya
    Han, Ja-Ryoung
    Park, Yang-Seok
    Cho, Yoon-Kyoung
    LAB ON A CHIP, 2015, 15 (02) : 478 - 485
  • [4] One-step Target Protein Detection from Whole Blood in a Lab-on-a-Disc
    Lee, B. S.
    Lee, J. -G.
    Lee, J. -N.
    Park, J. -M.
    Cho, Y. -K.
    Kim, S.
    Ko, C.
    NSTI NANOTECH 2008, VOL 3, TECHNICAL PROCEEDINGS: MICROSYSTEMS, PHOTONICS, SENSORS, FLUIDICS, MODELING, AND SIMULATION, 2008, : 241 - +
  • [5] Combined detection of C-reactive protein and PBMC quantification from whole blood in an integrated lab-on-a-disc microfluidic platform
    Uddin, Rokon
    Donolato, Marco
    Hwu, En-Te
    Hansen, Mikkel Fougt
    Boisen, Anja
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 272 : 634 - 642
  • [6] Label-free, spatially multiplexed SPR detection of immunoassays on a highly integrated centrifugal Lab-on-a-Disc platform
    Miyazaki, Celina M.
    Kinahan, David J.
    Mishra, Rohit
    Mangwanya, Faith
    Kilcawley, Niamh
    Ferreira, Marystela
    Ducree, Jens
    BIOSENSORS & BIOELECTRONICS, 2018, 119 : 86 - 93
  • [7] Systematic review of centrifugal valving based on digital twin modeling towards highly integrated lab-on-a-disc systems
    Jens Ducrée
    Microsystems & Nanoengineering, 7
  • [8] An immunoturbidimetric assay for specific proteins identification from whole blood based on multi-layered centrifugal microfluidic chip
    Yang, Jiachen
    Liu, Kangkang
    Yang, Minghao
    Wang, Guanghui
    ELEVENTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2019), 2019, 11209
  • [9] Systematic review of centrifugal valving based on digital twin modeling towards highly integrated lab-on-a-disc systems
    Ducree, Jens
    MICROSYSTEMS & NANOENGINEERING, 2021, 7 (01)
  • [10] An integrated microfluidic system for on-chip enrichment and quantification of circulating extracellular vesicles from whole blood
    Chen, Yi-Sin
    Ma, Yu-Dong
    Chen, Chihchen
    Shiesh, Shu-Chu
    Lee, Gwo-Bin
    LAB ON A CHIP, 2019, 19 (19) : 3305 - 3315