The rotate-plus-shift C-arm trajectory: Complete CT data with limited angular rotation

被引:1
|
作者
Ritschl, Ludwig [1 ]
Kuntz, Jan [2 ]
Kachelriess, Marc [2 ]
机构
[1] Ziehm Imaging GmbH, D-90451 Nurnberg, Germany
[2] German Canc Res Ctr, Med Phys Radiol, D-69120 Heidelberg, Germany
关键词
IMAGE-RECONSTRUCTION; SHORT SCAN;
D O I
10.1117/12.2081925
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the last decade C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm scan is performed using a circle-like trajectory around a region of interest. Therefor an angular range of at least 180 degrees plus fan-angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C-arm system, for example a larger C radius or a smaller C opening respectively. These technical modifications are usually not benificial in terms of handling and usability of the C-arm during classical 2D applications like fluoroscopy. The method proposed in this paper relaxes the constraint of 180 degrees plus fan-angle rotation to acquire a complete data set. The proposed C-arm trajectory requires a motorization of the orbital axis of the C and of ideally two orthogonal axis in the C plane. The trajectory consists of three parts: A rotation of the C around a defined iso-center and two translational movements parallel to the detector plane at the begin and at the end of the rotation. Combining these three parts to one trajectory enables for the acquisition of a completely sampled dataset using only 180 degrees minus fan-angle of rotation. To evaluate the method we show animal and cadaver scans acquired with a mobile C-arm prototype. We expect that the transition of this method into clinical routine will lead to a much broader use of intraoperative 3D imaging in a wide field of clinical applications.
引用
收藏
页数:4
相关论文
共 39 条
  • [31] Estimating 0th and 1th moments in C-arm CT data for extrapolating truncated projections
    Starman, J
    Pelc, N
    Strobel, N
    Fahrig, R
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 378 - 387
  • [32] C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance
    Guggenberger, Roman
    Ulbrich, Erika J.
    Dietrich, Tobias J.
    Scholz, Rosemarie
    Kaelin, Pascal
    Koehler, Christoph
    Elsaesser, Thilo
    Le Corroller, Thomas
    Pfammatter, Thomas
    Alkadhi, Hatem
    Andreisek, Gustav
    EUROPEAN RADIOLOGY, 2017, 27 (02) : 454 - 463
  • [33] Head Imaging with C-Arm CT: Investigation On the Impact of Data Redundancy Handling and Orientation of the Scanning Plane On Image Quality
    Guo, Z.
    Lauritsch, G.
    Maier, A.
    Noo, F.
    MEDICAL PHYSICS, 2017, 44 (06) : 3283 - 3283
  • [34] C-arm CT imaging with the extended line-ellipse-line trajectory: first implementation on a state-of-the-art robotic angiography system
    Guo, Zijia
    Lauritsch, Guenter
    Maier, Andreas
    Kugler, Patrick
    Islam, Mohammad
    Vogt, Florian
    Noo, Frederic
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (18):
  • [35] Cone-beam Tomography from Short-Scan Circle-plus-Arc Data Measured on a C-arm System
    Hoppe, Stefan
    Dennerlein, Frank
    Lauritsch, Guenter
    Hornegger, Joachim
    Noo, Frederic
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2873 - 2877
  • [36] Feasibility of internal-source tracking with C-arm CT/SPECT imaging with limited-angle projection data for online in vivo dose verification in brachytherapy: A Monte Carlo simulation study
    Sung, Saerom
    Lee, Minjae
    Choi, Hyung-Joo
    Park, Hyojun
    Cheon, Bo-Wi
    Min, Chul Hee
    Yeom, Yeon Soo
    Kim, Hyemi
    You, Sei Hwan
    Choi, Hyun Joon
    BRACHYTHERAPY, 2023, 22 (05) : 673 - 685
  • [37] Can Postoperative CT Imaging in Spine Surgery Be Replaced by Intraoperative 3D Rotation With the C-Arm?: Results of a Prospective Single Center Cohort Study
    Banat, Mohammed
    Wach, Johannes
    Salemdawod, Abdallah
    Domurath, Lisa
    Scorzin, Jasmin
    Vatter, Hartmut
    FRONTIERS IN SURGERY, 2021, 8
  • [38] Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory
    Zhuang, Tingliang
    Zambelli, Joseph
    Nett, Brian
    Leng, Shuai
    Chen, Guang-Hong
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [39] High Temporal Resolution Time-Resolved C-arm Cone-beam CT Imaging using a Multi-Sweep Data Acquisition Scheme
    Li, Yinsheng
    Garrett, John W.
    Li, Ke
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312