The rotate-plus-shift C-arm trajectory: Complete CT data with limited angular rotation

被引:1
|
作者
Ritschl, Ludwig [1 ]
Kuntz, Jan [2 ]
Kachelriess, Marc [2 ]
机构
[1] Ziehm Imaging GmbH, D-90451 Nurnberg, Germany
[2] German Canc Res Ctr, Med Phys Radiol, D-69120 Heidelberg, Germany
关键词
IMAGE-RECONSTRUCTION; SHORT SCAN;
D O I
10.1117/12.2081925
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the last decade C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm scan is performed using a circle-like trajectory around a region of interest. Therefor an angular range of at least 180 degrees plus fan-angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C-arm system, for example a larger C radius or a smaller C opening respectively. These technical modifications are usually not benificial in terms of handling and usability of the C-arm during classical 2D applications like fluoroscopy. The method proposed in this paper relaxes the constraint of 180 degrees plus fan-angle rotation to acquire a complete data set. The proposed C-arm trajectory requires a motorization of the orbital axis of the C and of ideally two orthogonal axis in the C plane. The trajectory consists of three parts: A rotation of the C around a defined iso-center and two translational movements parallel to the detector plane at the begin and at the end of the rotation. Combining these three parts to one trajectory enables for the acquisition of a completely sampled dataset using only 180 degrees minus fan-angle of rotation. To evaluate the method we show animal and cadaver scans acquired with a mobile C-arm prototype. We expect that the transition of this method into clinical routine will lead to a much broader use of intraoperative 3D imaging in a wide field of clinical applications.
引用
收藏
页数:4
相关论文
共 39 条
  • [21] Truncation artifacts caused by the patient table in polyenergetic statistical reconstruction on real C-arm CT data
    Bismark, Richard N. K.
    Beuing, Oliver
    Rose, Georg
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [22] C-arm based cone-beam CT using a two-concentric-arc source trajectory: system evaluation
    Zambelli, Joseph
    Zhuang, Tingliang
    Nett, Brian E.
    Riddell, Cyril
    Belanger, Barry
    Chen, Guang-Hong
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [23] Reduction of beam hardening artifacts on real C-arm CT data using polychromatic statistical image reconstruction
    Bismark, Richard N. K.
    Frysch, Robert
    Abdurahman, Shiras
    Beuing, Oliver
    Blessing, Manuel
    Rose, Georg
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (01): : 40 - 50
  • [24] Coping with real world data: Artifact reduction and denoising for motion-compensated cardiac C-arm CT
    Taubmann, Oliver
    Maier, Andreas
    Hornegger, Joachim
    Lauritsch, Guenter
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2016, 43 (02) : 883 - 893
  • [25] DYNAMIC PIXEL BINNING ALLOWS SPATIAL AND ANGULAR RESOLUTION TRADEOFFS TO IMPROVE IMAGE QUALITY IN X-RAY C-ARM CT
    Steg, Alexander
    Reichenbach, Marc
    Soell, Christopher
    Shi, Lan
    Maier, Andreas
    Riess, Christian
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 577 - 580
  • [26] Assessing cardiac function from total-variation-regularized 4D C-arm CT in the presence of angular undersampling
    Taubmann, O.
    Haase, V.
    Lauritsch, G.
    Zheng, Y.
    Krings, G.
    Hornegger, J.
    Maier, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (07): : 2762 - 2777
  • [27] Breathing motion compensated reconstruction for C-arm cone beam CT imaging: initial experience based on animal data
    Schaefer, D.
    Lin, M.
    Rao, P. P.
    Loffroy, R.
    Liapi, E.
    Noordhoek, N.
    Eshuis, P.
    Radaelli, A.
    Grass, M.
    Geschwind, J. -F. H.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [28] Comparing performance of many-core CPUs and GPUs for static and motion compensated reconstruction of C-arm CT data
    Hofmann, Hannes G.
    Keck, Benjamin
    Rohkohl, Christopher
    Hornegger, Joachim
    MEDICAL PHYSICS, 2011, 38 (01) : 468 - 473
  • [29] C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance
    Roman Guggenberger
    Erika J. Ulbrich
    Tobias J. Dietrich
    Rosemarie Scholz
    Pascal Kaelin
    Christoph Köhler
    Thilo Elsässer
    Thomas Le Corroller
    Thomas Pfammatter
    Hatem Alkadhi
    Gustav Andreisek
    European Radiology, 2017, 27 : 454 - 463
  • [30] Spine segmentation from C-arm CT data sets: application to region-of-interest volumes for spinal interventions
    Buerger, C.
    Lorenz, C.
    Babic, D.
    Hoppenbrouwers, J.
    Homan, R.
    Nachabe, R.
    Racadio, J. M.
    Grass, M.
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135