The rotate-plus-shift C-arm trajectory: Complete CT data with limited angular rotation

被引:1
|
作者
Ritschl, Ludwig [1 ]
Kuntz, Jan [2 ]
Kachelriess, Marc [2 ]
机构
[1] Ziehm Imaging GmbH, D-90451 Nurnberg, Germany
[2] German Canc Res Ctr, Med Phys Radiol, D-69120 Heidelberg, Germany
关键词
IMAGE-RECONSTRUCTION; SHORT SCAN;
D O I
10.1117/12.2081925
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the last decade C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm scan is performed using a circle-like trajectory around a region of interest. Therefor an angular range of at least 180 degrees plus fan-angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C-arm system, for example a larger C radius or a smaller C opening respectively. These technical modifications are usually not benificial in terms of handling and usability of the C-arm during classical 2D applications like fluoroscopy. The method proposed in this paper relaxes the constraint of 180 degrees plus fan-angle rotation to acquire a complete data set. The proposed C-arm trajectory requires a motorization of the orbital axis of the C and of ideally two orthogonal axis in the C plane. The trajectory consists of three parts: A rotation of the C around a defined iso-center and two translational movements parallel to the detector plane at the begin and at the end of the rotation. Combining these three parts to one trajectory enables for the acquisition of a completely sampled dataset using only 180 degrees minus fan-angle of rotation. To evaluate the method we show animal and cadaver scans acquired with a mobile C-arm prototype. We expect that the transition of this method into clinical routine will lead to a much broader use of intraoperative 3D imaging in a wide field of clinical applications.
引用
收藏
页数:4
相关论文
共 39 条
  • [1] The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation
    Ritschl, Ludwig
    Kuntz, Jan
    Fleischmann, Christof
    Kachelriess, Marc
    MEDICAL PHYSICS, 2016, 43 (05) : 2295 - 2302
  • [2] The Rotate-Plus-Shift C-Arm Trajectory: Theory and First Clinical Results
    Ritschl, L.
    Kachelriess, M.
    Kuntz, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3681 - 3681
  • [3] The rotate-plus-shift C-arm trajectory. Part II. Exact reconstruction from less than 180° rotation
    Kuntz, Jan
    Ritschl, Ludwig
    Knaup, Michael
    Kachelriess, Marc
    MEDICAL PHYSICS, 2016, 43 (05) : 2303 - 2310
  • [4] Shifted Detector Super Short Scan Reconstruction for the Rotate-Plus-Shift Trajectories and its Application to C-arm CT Systems
    Kuntz, Jan
    Knaup, Michael
    Fleischmann, Christof
    Kachelriess, Marc
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [5] Closed Sinusoid Trajectory for C-Arm CT Imaging
    Yang, Haiquan
    Li, Meihua
    Koizumi, Kazuhito
    Kudo, Hiroyuki
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3480 - 3484
  • [6] Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory
    Hoppe, Stefan
    Hornegger, Joachim
    Dennerlein, Frank
    Lauritsch, Guenter
    Noo, Frederic
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (01) : 73 - 86
  • [7] On C-arm CT imaging with the extended line-ellipse-line trajectory
    Guo, Z.
    Lauritsch, G.
    Maier, A.
    Kugler, P.
    Islam, M.
    Vogt, F.
    Noo, F.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [8] Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory
    Stefan Hoppe
    Joachim Hornegger
    Frank Dennerlein
    Günter Lauritsch
    Frédéric Noo
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 73 - 86
  • [9] Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
    Mehling, I.
    Rittstieg, P.
    Mehling, A. P.
    Kuechle, R.
    Mueller, L. P.
    Rommens, P. M.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38 (07) : 751 - 757
  • [10] A Realistic Digital Phantom for Perfusion C-arm CT based on MRI Data
    Aichert, Andre
    Manhart, Michael T.
    Navalpakkam, Bharath K.
    Grimm, Robert
    Hutter, Jana
    Maier, Andreas
    Hornegger, Joachim
    Doerfler, Arnd
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,