Accuracy and precision of the Transit Trackers System

被引:8
|
作者
Crout, David T. [1 ]
机构
[1] Tricty Metropolitan Transportat Dist Oregon, Portland, OR 97202 USA
关键词
D O I
10.3141/1992-11
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The accuracy and the precision of Transit Tracker, the Internet- and telephone-based real-time arrival information system of the Tri-County Metropolitan Transportation District of Oregon (TriMet), are analyzed. Although Transit Tracker estimates the arrival times of both bus and rail vehicles, this analysis is limited to bus vehicles. Archived data from TriMet's automatic vehicle location (AVL) and automatic passenger counter systems were used to compare actual bus arrival times with Transit Tracker estimates drawn from logs created in the estimation process. Accuracy was evaluated primarily by calculating the mean of the difference between the actual bus arrival times and the arrival times estimated by Transit Tracker. Precision was determined largely by the degree of variation in the estimates and measured by the standard deviation of the difference between the actual bus arrival times and the arrival times estimated by Transit Tracker. Finally, an arrival estimation error model was developed to test the effects of a series of factors on the degree of estimation error.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [41] Accuracy Performance Evaluation System for Precision Reducer Testing Machine
    Shi, Zhaoyao
    Yu, Zhiyong
    Cheng, Huiming
    Yu, Bo
    Zuo, Guangxiang
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2024, 60 (16): : 62 - 72
  • [42] Accuracy of spectral analysis methods for precision indoor positioning system
    Lauterbach, Martin
    Pola, Marek
    Zaplatilek, Ludek
    Bezousek, Pavel
    2014 10TH INTERNATIONAL CONFERENCE ON DIGITAL TECHNOLOGIES (DT), 2014, : 217 - 220
  • [43] Accuracy and precision assessment of a new blood glucose monitoring system
    Ji, Li-Nong
    Guo, Li-Xin
    Liu, Li-Bin
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (01) : 181 - 188
  • [44] Accuracy of Fitbit Activity Trackers During Walking in a Controlled Setting
    Gamez, Jose L.
    Gonzalez, Jesus
    Leyva, Perla
    Figueroa, Ivan A.
    Lucio, Naomi
    Salazar, Vanessa E.
    Salazar, Cindy
    Garcia, Miriam
    Funk, Merrill D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 363 - 363
  • [45] AN INTER-DEVICE ACCURACY COMPARISON OF CONSUMER SLEEP TRACKERS
    Zavrel, Erik A.
    Krieger, Ana C.
    2019 DESIGN OF MEDICAL DEVICES CONFERENCE, 2019,
  • [46] Accuracy Of Steps, Energy Expenditure, And Distance In Nine Activity Trackers
    Smith, Michael A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 362 - 362
  • [47] The Accuracy of Commercially Available Fitness Trackers in Patients after Stroke
    Holubova, Anna
    Mala, Eliska
    Hoidekrova, Kristyna
    Petioky, Jakub
    Duris, Andrea
    Muzik, Jan
    SENSORS, 2022, 22 (19)
  • [48] The application of transit dosimetry to precision radiotherapy
    Hansen, VN
    Evans, PM
    Swindell, W
    MEDICAL PHYSICS, 1996, 23 (05) : 713 - 721
  • [49] The Accuracy of Activity Trackers Measuring Energy Expenditure while Walking
    Cook, Melissa Renee
    Williams, Alyne L.
    Oliveira, Douglas Bernardes
    Wolgemuth, Christi
    Yoder, Whitney
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 374 - 374
  • [50] Encoded LED system for optical trackers
    Naimark, L
    Foxlin, E
    INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY, PROCEEDINGS, 2005, : 150 - 153