The Accuracy of Commercially Available Fitness Trackers in Patients after Stroke

被引:2
|
作者
Holubova, Anna [1 ]
Mala, Eliska [1 ]
Hoidekrova, Kristyna [2 ,3 ,4 ]
Petioky, Jakub [4 ,5 ]
Duris, Andrea [4 ]
Muzik, Jan [1 ]
机构
[1] Czech Tech Univ, Fac Biomed Engn, Kladno 27201, Czech Republic
[2] Charles Univ Prague, Fac Med 1, Prague 12800, Czech Republic
[3] Gen Univ Hosp, Prague 12800, Czech Republic
[4] Rehabil Ctr Kladruby, Kladruby 25762, Czech Republic
[5] Charles Univ Prague, Fac Med 3, Prague 10000, Czech Republic
关键词
activity tracker; physical activity; stroke; gait disorder; walking aid; PHYSICAL-ACTIVITY; WALKING SPEEDS; PEDOMETERS; SURVIVORS; VALIDITY;
D O I
10.3390/s22197392
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Fitness trackers could represent an easy-to-use and cheap tool for continuous tracking of physical activity of stroke survivors during the period of their recovery at home. The aim of the study was to examine the accuracy of the Fitbit activity tracker in locomotor activity monitoring of stroke survivors with respect to gait disorders, walking speed, walking aid, and placement of the tracker on body. Methods: Twenty-four ambulatory stroke survivors (15 men and 9 women) with locomotion/gait disorder were involved in the study. Patients underwent two walking tests with the Fitbit Alta HR trackers attached on 5 different places on body. The accuracy of the trackers has been analyzed on 3 groups of patients-those walking without any walking aid, those using a single-point stick and those using a rolling walker. Results: For no-aid patients, the most accurate place was the waist. Patients with a single-point stick revealed the smallest deviations for a tracker attached to a healthy lower limb, and patients with a rolling walker revealed the smallest deviations for a tracker attached on the paretic lower limb. Conclusions: An accuracy comparable with the healthy population can be reached for all of the three groups of patients, while fulfilling the conditions for minimum speed of 2 km/h and optimal placement of the trackers with respect to a walking aid and aspect to impairment.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Validity of Commercially Available Punch Trackers
    Omcirk, Dan
    Vetrovsky, Tomas
    Padecky, Jan
    Malecek, Jan
    Tufano, James J.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2023, 37 (11) : 2273 - 2281
  • [2] Field Evaluation of Commercially Available Youth Activity Trackers
    Sirard, John R.
    Masteller, Brittany R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 923 - 923
  • [3] Patients' experiences with commercially available activity trackers embedded in physiotherapy treatment: a qualitative study
    Ummels, Darcy
    Beekman, Emmylou
    Moser, Albine
    Braun, Susy M.
    Beurskens, Anna J.
    DISABILITY AND REHABILITATION, 2020, 42 (23) : 3284 - 3292
  • [4] How reliable are commercially available trackers in detecting daytime sleep
    Lambrechtse, Philip
    Ziesenitz, Victoria C.
    Cohen, Adam
    van den Anker, Johannes N.
    Bos, Ernst Jan
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2018, 84 (03) : 605 - 606
  • [5] Accuracy and Validity of Commercially Available Kayak Ergometers
    Borges, Thiago Oliveira
    Bullock, Nicola
    Aitken, David
    Coutts, Aaron J.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2017, 12 (09) : 1267 - 1270
  • [6] Accuracy and performance of a commercially available Dosing Aid
    Cronin, Tara H.
    Kahook, Malik Y.
    Lathrop, Kira L.
    Noecker, Robert J.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (04) : 497 - 499
  • [7] The validity of two commercially-available sleep trackers and actigraphy for assessment of sleep parameters in obstructive sleep apnea patients
    Gruwez, Alexia
    Bruyneel, Anne-Violette
    Bruyneel, Marie
    PLOS ONE, 2019, 14 (01):
  • [8] Validity Of Step Counting By Commercially Available Wearable Fitness Devices
    Doyle, Patrick
    Thomas, Jason W.
    Phung Tran
    Tippett, Robert, Jr.
    Kulkarni, Shreya
    Rogers, Joshua
    Doyle, J. Andrew
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 411 - 411
  • [9] Diagnostic Accuracy of Commercially Available Automated External Defibrillators
    Nishiyama, Takahiko
    Nishiyama, Ako
    Negishi, Masachika
    Kashimura, Shin
    Katsumata, Yoshinori
    Kimura, Takehiro
    Nishiyama, Nobuhiro
    Tanimoto, Yoko
    Aizawa, Yoshiyasu
    Mitamura, Hideo
    Fukuda, Keiichi
    Takatsuki, Seiji
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2015, 4 (12):
  • [10] The diagnostic accuracy of commercially available automated external defibrillators
    Nishiyama, T.
    Katsumata, Y.
    Kimura, T.
    Nishiyama, N.
    Tanimoto, Y.
    Aizawa, Y.
    Mitamura, H.
    Fukuda, K.
    Takatsuki, S.
    EUROPEAN HEART JOURNAL, 2014, 35 : 771 - 772