Validity of Commercially Available Punch Trackers

被引:2
|
作者
Omcirk, Dan [1 ]
Vetrovsky, Tomas [1 ]
Padecky, Jan [1 ]
Malecek, Jan [1 ]
Tufano, James J. [1 ]
机构
[1] Charles Univ Prague, Fac Phys Educ & Sport, Prague, Czech Republic
关键词
boxing; mixed martial arts; hand speed; accelerometer; wearable technology; RELIABILITY; KINEMATICS; VELOCITY;
D O I
10.1519/JSC.0000000000004535
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Supplemental Digital Content is Available in the Text. Omcirk, D, Vetrovsky, T, Padecky, J, Malecek, J, and Tufano, JJ. Validity of commercially available punch trackers. J Strength Cond Res 37(11): 2273-2281, 2023-This study determined how well data from commercially available punch trackers (Corner, Hykso, and StrikeTec) related to gold-standard velocity and force measures during full-contact punches. In a quasi-randomized order, 20 male subjects performed 6 individual rear straight punches, rear hooks, and rear uppercuts against a wall-mounted force plate. Punch tracker variables were compared with the peak force of the force plate and to the peak (QPV) and mean velocity (QMV) assessed through Qualisys 3-dimensional tracking. For each punch tracker variable, Pearson's correlation coefficient, mean absolute percentage error (MAPE), and mean percentage error (MPE) were calculated. There were no strong correlations between punch tracker data and gold-standard force and velocity data. However, Hykso "velocity" was moderately correlated with QMV (r = 0.68, MAPE 0.64, MPE 0.63) and QPV (r = 0.61, MAPE 0.21, MPE -0.06). Corner Power G was moderately correlated with QMV (r = 0.59, MAPE 0.65, MPE 0.58) and QPV (r = 0.58, MAPE 0.27, MPE -0.09), but Corner "velocity" was not. StrikeTec "velocity" was moderately correlated with QMV (r = 0.56, MAPE 1.49, MPE 1.49) and QPV (r = 0.55, MAPE 0.46, MPE 0.43). Therefore, none of the devices fared particularly well for all of their data output, and if not willing to accept any room for error, none of these devices should be used. Nevertheless, these devices and their proprietary algorithms may be updated in the future, which would warrant further investigation.
引用
收藏
页码:2273 / 2281
页数:9
相关论文
共 50 条
  • [1] Field Evaluation of Commercially Available Youth Activity Trackers
    Sirard, John R.
    Masteller, Brittany R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 923 - 923
  • [2] How reliable are commercially available trackers in detecting daytime sleep
    Lambrechtse, Philip
    Ziesenitz, Victoria C.
    Cohen, Adam
    van den Anker, Johannes N.
    Bos, Ernst Jan
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2018, 84 (03) : 605 - 606
  • [3] The Accuracy of Commercially Available Fitness Trackers in Patients after Stroke
    Holubova, Anna
    Mala, Eliska
    Hoidekrova, Kristyna
    Petioky, Jakub
    Duris, Andrea
    Muzik, Jan
    SENSORS, 2022, 22 (19)
  • [4] The validity of two commercially-available sleep trackers and actigraphy for assessment of sleep parameters in obstructive sleep apnea patients
    Gruwez, Alexia
    Bruyneel, Anne-Violette
    Bruyneel, Marie
    PLOS ONE, 2019, 14 (01):
  • [5] Accuracy and Validity of Commercially Available Kayak Ergometers
    Borges, Thiago Oliveira
    Bullock, Nicola
    Aitken, David
    Coutts, Aaron J.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2017, 12 (09) : 1267 - 1270
  • [6] Validity, reliability and feasibility of commercially available activity trackers in physical therapy for people with a chronic disease: A study protocol of a mixed methods research
    Beekman E.
    Braun S.M.
    Ummels D.
    van Vijven K.
    Moser A.
    Beurskens A.J.
    Pilot and Feasibility Studies, 3 (1)
  • [7] Patients' experiences with commercially available activity trackers embedded in physiotherapy treatment: a qualitative study
    Ummels, Darcy
    Beekman, Emmylou
    Moser, Albine
    Braun, Susy M.
    Beurskens, Anna J.
    DISABILITY AND REHABILITATION, 2020, 42 (23) : 3284 - 3292
  • [8] Validity and reliability of selected commercially available metabolic analyzer systems
    Hodges, LD
    Brodie, DA
    Bromley, PD
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2005, 15 (05) : 271 - 279
  • [9] Validity Of Step Counting By Commercially Available Wearable Fitness Devices
    Doyle, Patrick
    Thomas, Jason W.
    Phung Tran
    Tippett, Robert, Jr.
    Kulkarni, Shreya
    Rogers, Joshua
    Doyle, J. Andrew
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 411 - 411
  • [10] Counting Steps in Activities of Daily Living in People With a Chronic Disease Using Nine Commercially Available Fitness Trackers: Cross-Sectional Validity Study
    Ummels, Darcy
    Beekman, Emmylou
    Theunissen, Kyra
    Braun, Susy
    Beurskens, Anna J.
    JMIR MHEALTH AND UHEALTH, 2018, 6 (04): : 25 - 38