Supplemental Digital Content is Available in the Text. Omcirk, D, Vetrovsky, T, Padecky, J, Malecek, J, and Tufano, JJ. Validity of commercially available punch trackers. J Strength Cond Res 37(11): 2273-2281, 2023-This study determined how well data from commercially available punch trackers (Corner, Hykso, and StrikeTec) related to gold-standard velocity and force measures during full-contact punches. In a quasi-randomized order, 20 male subjects performed 6 individual rear straight punches, rear hooks, and rear uppercuts against a wall-mounted force plate. Punch tracker variables were compared with the peak force of the force plate and to the peak (QPV) and mean velocity (QMV) assessed through Qualisys 3-dimensional tracking. For each punch tracker variable, Pearson's correlation coefficient, mean absolute percentage error (MAPE), and mean percentage error (MPE) were calculated. There were no strong correlations between punch tracker data and gold-standard force and velocity data. However, Hykso "velocity" was moderately correlated with QMV (r = 0.68, MAPE 0.64, MPE 0.63) and QPV (r = 0.61, MAPE 0.21, MPE -0.06). Corner Power G was moderately correlated with QMV (r = 0.59, MAPE 0.65, MPE 0.58) and QPV (r = 0.58, MAPE 0.27, MPE -0.09), but Corner "velocity" was not. StrikeTec "velocity" was moderately correlated with QMV (r = 0.56, MAPE 1.49, MPE 1.49) and QPV (r = 0.55, MAPE 0.46, MPE 0.43). Therefore, none of the devices fared particularly well for all of their data output, and if not willing to accept any room for error, none of these devices should be used. Nevertheless, these devices and their proprietary algorithms may be updated in the future, which would warrant further investigation.
引用
收藏
页码:2273 / 2281
页数:9
相关论文
共 50 条
  • [21] Validity and repeatability of three commercially available in-shoe pressure measurement systems
    Carina Price
    Daniel Parker
    Christopher J Nester
    Journal of Foot and Ankle Research, 7 (Suppl 1)
  • [22] Validity Of Optical Heart Rate Measurement In Commercially Available Wearable Fitness Devices
    Thomas, Jason Wesley
    Doyle, Patrick
    Phung Tran
    Tippett, Robert, Jr.
    Kulkarni, Shreya
    Rogers, Joshua
    Doyle, J. Andrew
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 400 - 400
  • [23] Acceptability and Effects of Commercially Available Activity Trackers for Chronic Pain Management Among Older African American Adults
    Janevic, Mary R.
    Shute, Varick
    Murphy, Susan L.
    Piette, John D.
    PAIN MEDICINE, 2020, 21 (02) : E68 - E78
  • [24] Validity and Reliability of a Commercially Available Inertial Sensor for Measuring Barbell Mechanics during Weightlifting
    Chavda, Shyam
    Sandau, Ingo
    Bishop, Chris
    Xu, Jiaqing
    Turner, Anthony N.
    Lake, Jason P.
    APPLIED SCIENCES-BASEL, 2024, 14 (16):
  • [25] Community paramedic point of care testing: validity and usability of two commercially available devices
    Ian E. Blanchard
    Ryan Kozicky
    Dana Dalgarno
    Justin Simms
    Stacy Goulder
    Tyler S. Williamson
    Susan Biesbroek
    Lenore Page
    Karen Leaman
    Suzanne Snozyk
    Lyle Redman
    Keith Spackman
    Christopher J. Doig
    Eddy S. Lang
    Gerald Lazarenko
    BMC Emergency Medicine, 19
  • [26] Community paramedic point of care testing: validity and usability of two commercially available devices
    Blanchard, Ian E.
    Kozicky, Ryan
    Dalgarno, Dana
    Simms, Justin
    Goulder, Stacy
    Williamson, Tyler S.
    Biesbroek, Susan
    Page, Lenore
    Leaman, Karen
    Snozyk, Suzanne
    Redman, Lyle
    Spackman, Keith
    Doig, Christopher J.
    Lang, Eddy S.
    Lazarenko, Gerald
    BMC EMERGENCY MEDICINE, 2019, 19 (1)
  • [27] Commercially available accelerators
    Barbalat, O
    CAS - CERN ACCELERATOR SCHOOL - CYCLOTRONS, LINACS AND THEIR APPLICATIONS, 1996, 96 (02): : 395 - 398
  • [28] Commercially available biosurfactants
    Cozier, Muriel
    BIOFUELS BIOPRODUCTS & BIOREFINING-BIOFPR, 2016, 10 (01): : 10 - 10
  • [30] VALIDITY OF A COMMERCIALLY AVAILABLE URINE ETHYL GLUCURONIDE (ETG) TEST: DETECTION OF ABSTINENCE AND BINGE DRINKING
    Nguyen, X.
    Hanukaai, E. A.
    Bujarski, S.
    Ray, L. A.
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2018, 42 : 264A - 264A