Effectiveness of 3D T2-Weighted FLAIR FSE Sequences with Fat Suppression for Detection of Brain MR Imaging Signal Changes in Children

被引:6
|
作者
Mascalchi, M. [1 ,2 ]
Bianchi, A. [1 ]
Basile, M. [3 ]
Gulino, P. [3 ]
Trifan, M. R. [3 ]
Difeo, D. [3 ]
Bartolini, E. [4 ]
Defilippi, C. [3 ]
Diciotti, S. [5 ]
机构
[1] Univ Florence, Mario Serio Dept Expt & Clin Biomed Sci, Viale Morgagni 50, I-50134 Florence, Italy
[2] Meyer Childrens Hosp, Struct & Funct Neuroradiol Res Unit, Florence, Italy
[3] Meyer Childrens Hosp, Diagnost Radiol, Florence, Italy
[4] Meyer Childrens Hosp, Neurol Unit & Labs, Florence, Italy
[5] Univ Bologna, Dept Elect Elect & Informat Engn Guglielmo Marcon, Cesena, Italy
关键词
2D FLAIR; MULTIPLE-SCLEROSIS; CEREBROSPINAL-FLUID; INITIAL EXPERIENCE; PEDIATRIC BRAIN; ARTIFACTS;
D O I
10.3174/ajnr.A4915
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: T2-weighted FLAIR can be combined with 3D-FSE sequences with isotropic voxels, yielding higher signal-to-noise ratio than 2D-FLAIR. Our aim was to explore whether a T2-weighted FLAIR volume isotropic turbo spin-echo acquisition sequence (FLAIR-VISTA) with fat suppression shows areas of abnormal brain T2 hyperintensities with better conspicuity in children than a single 2D-FLAIR sequence. MATERIALS AND METHODS: One week after a joint training session with 20 3T MR imaging examinations (8 under sedation), 3 radiologists independently evaluated the presence and conspicuity of abnormal areas of T2 hyperintensities of the brain in FLAIR-VISTA with fat suppression (sagittal source and axial and coronal reformatted images) and in axial 2D-FLAIR without fat suppression in a test set of 100 3T MR imaging examinations (34 under sedation) of patients 2-18 years of age performed for several clinical indications. Their agreement was measured with weighted kappa statistics. RESULTS: Agreement was "substantial" (mean, 0.61 for 3 observers; range, 0.49-0.69 for observer pairs) for the presence of abnormal T2 hyperintensities and "fair" (mean, 0.29; range, 0.23-0.38) for the comparative evaluation of lesion conspicuity. In 21 of 23 examinations in which the 3 radiologists agreed on the presence of abnormal T2 hyperintensities, FLAIR-VISTA with fat suppression images were judged to show hyperintensities with better conspicuity than 2D-FLAIR. In 2 cases, conspicuity was equal, and in no case was conspicuity better in 2D-FLAIR. CONCLUSIONS: FLAIR-VISTA with fat suppression can replace the 2D-FLAIR sequence in brain MR imaging protocols for children.
引用
收藏
页码:2376 / 2381
页数:6
相关论文
共 50 条
  • [41] Mapping pathological changes in brain structure by combining T1-and T2-weighted MR imaging data
    Ganzetti, Marco
    Wenderoth, Nicole
    Mantini, Dante
    NEURORADIOLOGY, 2015, 57 (09) : 917 - 928
  • [42] Mapping pathological changes in brain structure by combining T1- and T2-weighted MR imaging data
    Marco Ganzetti
    Nicole Wenderoth
    Dante Mantini
    Neuroradiology, 2015, 57 : 917 - 928
  • [43] Contrast Enhancement of the Anterior Eye Segment and Subarachnoid Space: Detection in the Normal State by Heavily T2-weighted 3D FLAIR
    Naganawa, Shinji
    Yamazaki, Masahiro
    Kawai, Hisashi
    Sone, Michihiko
    Nakashima, Tsutomu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2011, 10 (03) : 193 - 199
  • [44] Quantitative comparison of brain lesion contrast with fast FLAIR and fast SE proton-density- and T2-weighted MR imaging
    Mathews, VP
    Caldemeyer, KS
    Weber, DM
    RADIOLOGY, 1996, 201 : 975 - 975
  • [45] MR imaging of articular cartilage at 1.5T and 3.0T: comparison of IDEAL 2D FSE and 3D SPGR with fat-saturated 2D FSE and 3D SPGR in a porcine model
    Cha, Jang Gyu
    Yoo, Jae Ho
    Rhee, Sun Jung
    Hwang, Seung Sik
    Han, Jong Kyu
    ACTA RADIOLOGICA, 2014, 55 (04) : 462 - 469
  • [46] T2-Weighted 3D Fast Spin Echo Imaging With Water-Fat Separation in a Single Acquisition
    Madhuranthakam, Ananth J.
    Yu, Huanzhou
    Shimakawa, Ann
    Busse, Reed F.
    Smith, Martin P.
    Reeder, Scott B.
    Rofsky, Neil M.
    Brittain, Jean H.
    McKenzie, Charles A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (03) : 745 - 751
  • [47] Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T
    Eliezer, Michael
    Vaussy, Alexis
    Toupin, Solenn
    Barbe, Remy
    Kannengiesser, Stephan
    Stemmer, Alto
    Houdart, Emmanuel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 13 - 20
  • [48] MR-IMAGING EVALUATION OF KNEE COLLATERAL LIGAMENTS AND RELATED INJURIES - COMPARISON OF T1-WEIGHTED, T2-WEIGHTED, AND FAT-SATURATED T2-WEIGHTED SEQUENCES - CORRELATION WITH CLINICAL FINDINGS
    MIROWITZ, SA
    SHU, HH
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 725 - 732
  • [49] The comparison of the efficacy of diffusion weighted imaging (DWI) sequences with 3 different T2-weighted sequences in the detection of focal liver lesions
    Dilek, O.
    Gulek, B.
    Yilmaz, C.
    Kaya, O.
    Soker, G.
    Akin, M. A.
    ACTA GASTRO-ENTEROLOGICA BELGICA, 2019, 82 (02) : 267 - 272
  • [50] 3D T2-weighted imaging to shorten multiparametric prostate MRI protocols
    Stephan H. Polanec
    Mathias Lazar
    Georg J. Wengert
    Hubert Bickel
    Claudio Spick
    Martin Susani
    Shahrokh Shariat
    Paola Clauser
    Pascal A. T. Baltzer
    European Radiology, 2018, 28 : 1634 - 1641