Effectiveness of 3D T2-Weighted FLAIR FSE Sequences with Fat Suppression for Detection of Brain MR Imaging Signal Changes in Children

被引:6
|
作者
Mascalchi, M. [1 ,2 ]
Bianchi, A. [1 ]
Basile, M. [3 ]
Gulino, P. [3 ]
Trifan, M. R. [3 ]
Difeo, D. [3 ]
Bartolini, E. [4 ]
Defilippi, C. [3 ]
Diciotti, S. [5 ]
机构
[1] Univ Florence, Mario Serio Dept Expt & Clin Biomed Sci, Viale Morgagni 50, I-50134 Florence, Italy
[2] Meyer Childrens Hosp, Struct & Funct Neuroradiol Res Unit, Florence, Italy
[3] Meyer Childrens Hosp, Diagnost Radiol, Florence, Italy
[4] Meyer Childrens Hosp, Neurol Unit & Labs, Florence, Italy
[5] Univ Bologna, Dept Elect Elect & Informat Engn Guglielmo Marcon, Cesena, Italy
关键词
2D FLAIR; MULTIPLE-SCLEROSIS; CEREBROSPINAL-FLUID; INITIAL EXPERIENCE; PEDIATRIC BRAIN; ARTIFACTS;
D O I
10.3174/ajnr.A4915
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: T2-weighted FLAIR can be combined with 3D-FSE sequences with isotropic voxels, yielding higher signal-to-noise ratio than 2D-FLAIR. Our aim was to explore whether a T2-weighted FLAIR volume isotropic turbo spin-echo acquisition sequence (FLAIR-VISTA) with fat suppression shows areas of abnormal brain T2 hyperintensities with better conspicuity in children than a single 2D-FLAIR sequence. MATERIALS AND METHODS: One week after a joint training session with 20 3T MR imaging examinations (8 under sedation), 3 radiologists independently evaluated the presence and conspicuity of abnormal areas of T2 hyperintensities of the brain in FLAIR-VISTA with fat suppression (sagittal source and axial and coronal reformatted images) and in axial 2D-FLAIR without fat suppression in a test set of 100 3T MR imaging examinations (34 under sedation) of patients 2-18 years of age performed for several clinical indications. Their agreement was measured with weighted kappa statistics. RESULTS: Agreement was "substantial" (mean, 0.61 for 3 observers; range, 0.49-0.69 for observer pairs) for the presence of abnormal T2 hyperintensities and "fair" (mean, 0.29; range, 0.23-0.38) for the comparative evaluation of lesion conspicuity. In 21 of 23 examinations in which the 3 radiologists agreed on the presence of abnormal T2 hyperintensities, FLAIR-VISTA with fat suppression images were judged to show hyperintensities with better conspicuity than 2D-FLAIR. In 2 cases, conspicuity was equal, and in no case was conspicuity better in 2D-FLAIR. CONCLUSIONS: FLAIR-VISTA with fat suppression can replace the 2D-FLAIR sequence in brain MR imaging protocols for children.
引用
收藏
页码:2376 / 2381
页数:6
相关论文
共 50 条
  • [31] Evaluation of optimized inversion-recovery fat-suppression techniques for T2-weighted abdominal MR imaging
    Lauenstein, Thomas C.
    Sharma, Puneet
    Hughes, Timothy
    Heberlein, Keith
    Tudorascu, Dana
    Martin, Diego R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1448 - 1454
  • [32] T2-WEIGHTED MR-IMAGING OF THE UPPER PART OF THE ABDOMEN - SHOULD FAT-SUPPRESSION BE USED ROUTINELY
    LU, DSK
    SAINI, S
    HAHN, PF
    GOLDBERG, M
    LEE, MJ
    WEISSLEDER, R
    GERARD, B
    HALPERN, E
    CATS, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (05) : 1095 - 1100
  • [33] Comparison of 3D and 2D FSE T2-weighted MRI in the diagnosis of deep pelvic endometriosis: Preliminary results
    Bazot, M.
    Stivalet, A.
    Darai, E.
    Coudray, C.
    Thomassin-Naggara, I.
    Poncelet, E.
    CLINICAL RADIOLOGY, 2013, 68 (01) : 47 - 54
  • [34] MR arthrography of the hip: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences
    Giovanni Foti
    Antonio Campacci
    Michele Conati
    Mirko Trentadue
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2017, 122 : 774 - 784
  • [35] Changes in myometrial and junctional zone thickness and signal intensity: demonstration with kinematic T2-weighted MR imaging
    Masui, T
    Katayama, M
    Kobayashi, S
    Nakayama, S
    Nozaki, A
    Kabasawa, H
    Ito, T
    Sakahara, H
    RADIOLOGY, 2001, 221 (01) : 75 - 85
  • [36] MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences
    Giovanni Foti
    Paolo Avanzi
    William Mantovani
    Flavia Dal Corso
    Emanuele Demozzi
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2017, 122 : 353 - 360
  • [37] MR arthrography of the hip: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences
    Foti, Giovanni
    Campacci, Antonio
    Conati, Michele
    Trentadue, Mirko
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2017, 122 (10): : 774 - 784
  • [38] MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences
    Foti, Giovanni
    Avanzi, Paolo
    Mantovani, William
    Dal Corso, Flavia
    Demozzi, Emanuele
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2017, 122 (05): : 353 - 360
  • [39] MR urography (MRU) of non-dilated ureter with diuretic administration: Static fluid 2D FSE T2-weighted versus 3D gadolinium T1-weighted GE excretory MR
    Roy, C.
    Ohana, M.
    Host, Ph.
    Alemann, G.
    Labani, A.
    Wattiez, A.
    Lang, H.
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2014, 1 : 6 - 13
  • [40] Spiral 2D T2-Weighted TSE Brain MR Imaging: Initial Clinical Experience
    Sartoretti, E.
    Sartoretti-Schefer, S.
    van Smoorenburg, L.
    Binkert, C. A.
    Gutzeit, A.
    Wyss, M.
    Sartoretti, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (11) : 1962 - 1967