The research on relationship of load rate and outdoor temperature for air-cooled unit

被引:0
|
作者
Gao, Liying [1 ]
Li, Rui [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Sch Environm & Energy Engn, Beijing 100044, Peoples R China
来源
关键词
IPLV; Load rate; Outdoor temperature; Chillers; Running time;
D O I
10.4028/www.scientific.net/AMR.347-353.1210
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the paper, based on the current understanding of the IPLV principle and method of calculation, select occurrence temperature during the cooling season in five typical cities for further calculating the equation of IPLV, which exist quite differences with the current national standard IPLV formula. Moreover, the study of load rate for chillers will definitely closely relate to the climatic conditions in China.
引用
收藏
页码:1210 / 1213
页数:4
相关论文
共 50 条
  • [31] Load Capacity Evaluation of Forced Guided Oil Circulation Air-cooled Transformer Based on Temperature Rise Characteristics
    Liu G.
    Lan H.
    Jiang X.
    Liu Y.
    Wang W.
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (01): : 232 - 242
  • [32] Research on impact of cooling fan’s geometry on nozzle’s heat load of the air-cooled diesel engine
    Department of Mechanical and Energy Engineering, Shaoyang University, Shaoyang, China
    Open Mech. Eng. J., 1 (99-105):
  • [33] Air-cooled full-SiC high power density inverter unit
    Murakami, Yoshinori
    Tajima, Yutaka
    Tanimoto, Satoshi
    World Electric Vehicle Journal, 2013, 6 (03): : 669 - 672
  • [34] Analysis on part load operation performance of HAILLER indirect air-cooled system with adjunctive cooled system
    Hao, Man-Jin
    Tu, Guang-Bei
    Chen, Guan-Yi
    Jia, Jing-Fu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2008, 29 (10): : 1636 - 1640
  • [35] Performance monitoring of direct air-cooled power generating unit with infrared thermography
    Ge, Zhihua
    Du, Xiaoze
    Yang, Lijun
    Yang, Yongping
    Li, Yanlei
    Jin, Yansheng
    APPLIED THERMAL ENGINEERING, 2011, 31 (04) : 418 - 424
  • [36] Failure analysis of an air-cooled heat exchanger in natural gas dehydration unit
    Javidi, Mehdi
    Sadeghi, Mohammad Amin
    Jafari, Raheleh
    Hoodi, Amir Ardalan
    ENGINEERING FAILURE ANALYSIS, 2020, 115
  • [37] Numerical study on spray humidification system used in the direct air-cooled unit
    Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Baoding 071003, China
    Zhongguo Dianji Gongcheng Xuebao, 2008, 29 (28-33):
  • [38] Research on the variation law of the Tube's Inside-Wall Temperature of Direct Air-Cooled Condenser
    Zhao, Hongbin
    Wu, Haixia
    Yan, Yonghui
    Li, Meng
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [39] A high-temperature assessment of air-cooled unsteady pressure transducers
    Ferguson, D.G.
    Ivey, P.C.
    Journal of Turbomachinery, 1998, 120 (03): : 608 - 612
  • [40] Methodology for the estimation of head inner surface temperature in an air-cooled engine
    Carvajal-Trujillo, Elisa
    Jimenez-Espadafor, Francisco J.
    Becerra Villanueva, Jose A.
    Torres Garcia, Miguel
    APPLIED THERMAL ENGINEERING, 2012, 35 : 202 - 211