Load Capacity Evaluation of Forced Guided Oil Circulation Air-cooled Transformer Based on Temperature Rise Characteristics

被引:0
|
作者
Liu G. [1 ]
Lan H. [1 ]
Jiang X. [2 ]
Liu Y. [1 ]
Wang W. [2 ]
机构
[1] Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding
[2] Electric Power Research Institute, State Grid Zhejiang Electric Power Company, Hangzhou
来源
关键词
load capacity; ODAF cooling mode; temperature rise characteristic; thermal model; transformer;
D O I
10.13336/j.1003-6520.hve.20230314
中图分类号
学科分类号
摘要
Aiming at the problem that the load capacity of forced guided oil circulation air-cooled(ODAF) transformer is affected by the temperature rise constraint, this paper proposes three kinds of load capacity evaluation methods for transformer. Firstly, the running state of fan and oil pump and the influence of oil viscosity change on thermal resistance and other factors are taken into account, and a transformer thermal model is established based on thermoelectric analogy method to calculate winding hot spot and top oil temperature. Secondly, particle swarm optimization algorithm(PSO) is used to fit the parameters of the thermal model; meanwhile, based on the operation data of two different types of transformers, the calculation accuracy of the thermal model and the suitability of the fitting parameters are validated. Finally, a load capacity evaluation model based on the temperature rise characteristics is proposed by referring to the temperature rise limit given in the load guide GB/T 1094.7. The analysis results show that the error of hot spot temperature calculated by the proposed model is no more than 2.35 ℃, which is within the allowable range of engineering. Under normal periodic load, when the ambient temperature is lower than 1 ℃, the temperature rise constraint is still satisfied after closing a group of sub-radiators. © 2024 Science Press. All rights reserved.
引用
收藏
页码:232 / 242
页数:10
相关论文
共 22 条
  • [1] ZHOU Lijun, TANG Haolong, WANG Lujia, Et al., Modeling and analysis of transformer overload based on top oil temperature rise, High Voltage Engineering, 45, 8, pp. 2502-2508, (2019)
  • [2] LI Yuan, LIU Ning, LIANG Yu, Et al., A model of load capacity assessment for oil-immersed transformer by using temperature rise characteristics, Proceedings of the CSEE, 38, 22, pp. 6737-6745, (2018)
  • [3] AUBIN J, LANGHAME Y., Effect of oil viscosity on transformer loading capability at low ambient temperatures, IEEE Transactions on Power Delivery, 7, 2, pp. 516-524, (1992)
  • [4] XU Xiaogang, HE Yunwen, LI Xin, Et al., Overload capacity for distribution transformers with natural-ester immersed high-temperature resistant insulating paper, Power System Technology, 42, 3, pp. 1001-1006, (2018)
  • [5] CHEN Weigen, SU Xiaoping, CHEN Xi, Et al., Influence factor analysis and improvement of the thermal model for predicting transformer top oil temperature, High Voltage Engineering, 37, 6, pp. 1329-1335, (2011)
  • [6] IEEE guide for loading mineral-oil-immersed transformers: C57.91—1995, (1996)
  • [7] TAHERI A A, ABADLI A, TAGHILOU M, Et al., Investigation of mineral oil-based nanofluids effect on oil temperature reduction and loading capacity increment of distribution transformers, Energy Reports, 7, pp. 4325-4334, (2021)
  • [8] HAJEFOROSH S F, KHATUN A, BOLLEN M., Enhancing the hosting capacity of distribution transformers for using dynamic component rating, International Journal of Electrical Power and Energy Systems, 142, (2022)
  • [9] Power transformers-part 7: loading guide for oil-immersed power transformer: GB/T 1094.7—2008, (2009)
  • [10] ZHOU Zeru, CHEN Bin, LI Yingguang, Transformer load capacity assessment model based on thermoelectric analogy, Guangdong Electric Power, 34, 4, pp. 101-106, (2021)